• Title/Summary/Keyword: Low-Band Type

Search Result 386, Processing Time 0.03 seconds

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

KMTNET SUPERNOVA PROGRAM VARIABLE OBJECTS I. NGC 2784 FIELD

  • HE, MATTHIAS YANG;MOON, DAE-SIK;NEILSON, HILDING;LEE, JAE-JOON;KIM, SANG CHUL;PAK, MINA;PARK, HONG SOO;KIM, DONG-JIN;LEE, YONGSEOK;KIM, SEUNG-LEE;LEE, CHUNG-UK
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.5
    • /
    • pp.209-223
    • /
    • 2016
  • We present analyses of ~1250 variable sources identified in a 20 square degree field toward NGC 2784 by the KMTNet Supernova Program. We categorize the variable sources into three groups based on their B-band variability. The first group consists of 31 high variability sources with their B-band RMS variability greater than 0.3 magnitudes. The second group of medium variability contains 265 sources with RMS variability between 0.05 and 0.3 magnitudes. The remaining 951 sources belong to the third group of low variability with an RMS variability smaller than 0.05 magnitudes. Of the entire ~1250 sources, 4 clearly show periods of variability greater than 100 days, while the rest have periods shorter than ~51 days or no reliable periods. The majority of the sources show either rather irregular variability or short periods faster than 2 days. Most of the sources with reliable period determination between 2 and 51 days belong to the low-variability group, although a few belong to the medium-variability group. All the variable sources with periods longer than 35 days appear to be very red with B - V > 1.5 and V - I > 2.1 magnitudes. We classify candidates of 51 Cepheids, 17 semi-regular variables, 3 Mira types, 2 RV(B) Tauri stars, 26 eclipsing binary systems and 1 active galactic nucleus. The majority of long-term variables in our sample belong to either Mira or semi-regular types, indicating that long-term variability may be more prominent in post-main sequence phases of late-type stars. The depth of the eclipsing dips of the 26 candidates for eclipsing binaries is equivalent to ~0.61 as the average relative size of the two stars in the binary system. Our results illustrate the power of the KMTNet Supernova Program for future studies of variable objects.

Genetic Diversity of Xanthomonas arboricola pv. pruni Isolated in Korea (우리나라에서 분리한 Xanthomonas arboricola pv. pruni의 유전적 다양성)

  • Park, So-Yeon;Lee, Young-Sun;Shin, Jong-Sub;Koh, Young-Jin;Jung, Jae-Sung
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.684-687
    • /
    • 2009
  • Xanthomonas arboricola pv. pruni, the causal agent of bacterial shot holes in stone fruits, was known to have a low population diversity. To investigate the genetic characteristics of X. arboricola pv. pruni isolated in Korea, three strains which have identical 16S rDNA sequences - including type strain (LMG852), Japanese isolate (MAFF301420) and Korean isolate (XWD1) - were analysed based on the nucleotide sequences of three DNA regions and RAPD pattern. No sequence diversity among the three strains was found within the ITS, glnA and atpD gene sequences. However, five of 756 nucleotides of the atpD gene determined (accession number FJ429319) were different from those of the French strain available from the Genbank database. RAPD analyses performed with 40 different arbitrary primers revealed that two strains isolated from Korea and Japan showed similarity in their band patterns distinguished by type strain. These results suggest that Korean and Japanese strains are very close and belong to a population with a low genetic diversity, and might have a different origin from strains found in West Europe.

Two Stage CMOS Class E RF Power Amplifier (2단 CMOS Class E RF 전력증폭기)

  • 최혁환;김성우;임채성;오현숙;권태하
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.1
    • /
    • pp.114-121
    • /
    • 2003
  • In this paper, low voltage and two stage CMOS Class E RF power amplifier for ISM(Industrial/Scientific/Medical) Open Band is presented. The power amplifier operates at 2.4GHz frequency, and is designed and simulated with a 0.35um CMOS technology and HSPICE simulator. The power amplifier is simple structure of two stage Class E power amplifier. The design procedure determing matching network was presented. The power amplifier is composed of input stage matching network, preamplifier, interstage matching network, power amplifier, and output stage matching network. The matching networks of input stage and interstage were constituted by pi($\pi$) type and L type respectively. At 2.4GHz operating frequency, and with a 2.5V supply voltage, the power amplifier delivers 23dBm output power to a 50${\Omega}$ load with 39% power added efficiency(PAE).

Mechanisms of Chilling Tolerance in Relation to Antioxidative Enzymes in Rice

  • Kuk, Yong-In;Shin, Ji-San;Whang, Tay-Eak;Guh, Ja-Ock
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.5
    • /
    • pp.341-351
    • /
    • 2002
  • In order to examine the mechanistic basis for differential sensitivities to chilling and subsequent recovery between two rice (Oryza sativa L.) cutivars, a chilling-tolerant japonica type (Ilpumbyeo) and a chilling-susceptible indica type (Taebaekbyeo), changes of physiological responses and antioxidant enzymes were investigated. Both cultivars at 3 leaf stage were exposed at a low temperature of $5^{\circ}C$ for 3 days and subsequently recovered in a growth chamber at a $25^{\circ}C$ for 5 days with 250 mmol $m^{-2}$ $s^{-1}$. Physiological parameters such as leaf fresh weight, relative water content, cellular leakage, lipid peroxidation, and chlorophyll a fluorescence showed that the chilling tolerant cultivar had a high tolerance during chilling. However, the chilling-susceptible cultivar revealed severe chilling damages. The chilling-tolerant cultivar was also faster in recovery than the chilling-susceptible cultivar in all parameters examined. We analyzed the activity and isozyme profiles of four antioxidant enzymes which are: superoxide dismutase (SOD), caltalase (CAT), ascorbate peroxidase (APX), and glutation reductase (GR). We observed that chilling-tolerance was due to a result of the induced or higher antioxidant enzyme system, CAT and APX in leaves and SOD, CAT, APX, and GR in roots. Especially, we observed the most significant differences between the chilling-tolerant cultivar and -susceptible cultivar in CAT and APX activity. Also in isozyme profiles, CAT and APX band intensity in the chilling-tolerant cultivar was distinctively higher than in the chilling-susceptible cultivars during chilling and recovery. Thus, the cold stability of CAT and APX are expected to contribute to a tolerance mechanism of chilling in rice plants. In addition, the antioxidative enzymes activity in roots may be more important than in that of leaves to protect chilling damage on rice plants.

Design of a Wideband Frequency Synthesizer with Low Varactor Control Voltage (낮은 바렉터 제어 전압을 이용한 광대역 주파수 합성기 설계)

  • Won, Duck-Ho;Choi, Kwang-Seok;Yun, Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • In this paper, with using the clapp type VCO(Voltage Controlled Osillator) configuration a wideband frequency synthesizer in UHF band is proposed. In order to design a wideband frequency synthesizer, the variation of phase in the negative resistance circuit as well as the load circuit was analyzed. Based on this result we propose a method to widen the operation range of the VCO. A frequency synthesizer using the proposed wideband VCO was designed and fabricated. It is shown that the synthesizer has the operating frequency range of 740~1,530 MHz by 0~5 V varactor tuning voltage, and it had the output power of 2~-6 dBm. Moreover, the phase noise measured as -77 dBc/Hz at 10 kHz offset, and as -108 dBc/Hz at 100 kHz offset from the oscillation frequency.

Implementation of RF Oscillator Using Microstrip Split Ring Resonator (SRR) (마이크로스트립 분리형 링 공진기를 이용한 RF 발진기 구현)

  • Kim, Girae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.273-279
    • /
    • 2013
  • In this paper, a novel split ring resonator is proposed for improvement of phase noise characteristics that is weak point of oscillator using planar type microstrip line resonator, and oscillator for 5.8GHz band is designed using proposed split ring resonator. At the fundamental frequency of 5.8GHz, 7.22dBm output power and -83.5 dBc@100kHz phase noise have been measured for oscillator with split ring resonator. The phase noise characteristics of oscillator is improved about 9.7dB compared to one using the general ${\lambda}$/4 microstrip resonator. Because it is possible that varactor diode or lumped capacitor is placed on the gaps of split ring resonator, resonant frequency can be controlled by bias voltage. We can design voltage controlled oscillator using proposed split ring resonator. Thus, due to its simple fabrication process and planar type, it is expected that the technique in this paper can be widely used for low phase noise oscillators for both MIC and MMIC applications.

Electronic, Optical and Electrical Properties of Nickel Oxide Thin Films Grown by RF Magnetron Sputtering

  • Park, Chanae;Kim, Juhwan;Lee, Kangil;Oh, Suhk Kun;Kang, Hee Jae;Park, Nam Seok
    • Applied Science and Convergence Technology
    • /
    • v.24 no.3
    • /
    • pp.72-76
    • /
    • 2015
  • Nickel oxide (NiO) thin films were grown on soda-lime glass substrates by RF magnetron sputtering method at room temperature (RT), and they were post-annealed at the temperatures of $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$ and $400^{\circ}C$ for 30 minutes in vacuum. The electronic structure, optical and electrical properties of NiO thin films were investigated using X-ray photoelectron spectroscopy (XPS), reflection electron energy spectroscopy (REELS), UV-spectrometer and Hall Effect measurements, respectively. XPS results showed that the NiO thin films grown at RT and post annealed at temperatures below $300^{\circ}C$ had the NiO phase, but, at $400^{\circ}C$, the nickel metal phase became dominant. The band gaps of NiO thin films post annealed at temperatures below $300^{\circ}C$ were about 3.7 eV, but that at $400^{\circ}C$ should not be measured clearly because of the dominance of Ni metal phase. The NiO thin films post-annealed at temperatures below $300^{\circ}C$ showed p-type conductivity with low electrical resistivity and high optical transmittance of 80% in the visible light region, but that post-annealed at $400^{\circ}C$ showed n-type semiconductor properties, and the average transmittance in the visible light region was less than 42%. Our results demonstrate that the post-annealing plays a crucial role in enhancing the electrical and optical properties of NiO thin films.

Fabrication and Characterization of CuO Thin Film/ZnO Nanorods Heterojunction Structure for Efficient Detection of NO Gas (일산화질소 가스 검출을 위한 CuO 박막/ZnO 나노막대 이종접합 구조의 제작 및 특성 평가)

  • Yoo, Hwansu;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.28 no.1
    • /
    • pp.32-37
    • /
    • 2018
  • We report on the efficient detection of NO gas by an all-oxide semiconductor p-n heterojunction diode structure comprised of n-type zinc oxide (ZnO) nanorods embedded in p-type copper oxide (CuO) thin film. The CuO thin film/ZnO nanorod heterostructure was fabricated by directly sputtering CuO thin film onto a vertically aligned ZnO nanorod array synthesized via a hydrothemal method. The transport behavior and NO gas sensing properties of the fabricated CuO thin film/ZnO nanorod heterostructure were charcterized and revealed that the oxide semiconductor heterojunction exhibited a definite rectifying diode-like behavior at various temperatures ranging from room temperature to $250^{\circ}C$. The NO gas sensing experiment indicated that the CuO thin film/ZnO nanorod heterostructure had a good sensing performance for the efficient detection of NO gas in the range of 2-14 ppm under the conditions of an applied bias of 2 V and a comparatively low operating temperature of $150^{\circ}C$. The NO gas sensing process in the CuO/ZnO p-n heterostructure is discussed in terms of the electronic band structure.

Design of Compact Planar Quasi-Yagi Antenna for DTV Reception (디지털방송 수신용 평면 준-야기 안테나의 소형화 설계)

  • Lee, Jong-Ig;Han, Dae-Hee;Kim, Soo-Min;Kim, Gun-Kyun;Yeo, Junho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.583-585
    • /
    • 2012
  • In this paper, we introduce a design method for a broadband planar quasi-Yagi antenna (QYA) for terrestrial digital television (DTV) receiving. The coplanar strip line feeding the driver dipole is connected to a microstrip line and is terminated by short circuit. By appending a wide strip-type director at a location close to the driver dipole, a broadband impedance matching and a gain characteristics in a high frequency region are obtained. The gain characteristics in a low frequency region are improved by adding a reflector formed by a truncated ground plane. To reduce the antenna size, the strip-type dipole and reflector are modified to half bowtie (V)-shaped elements. The effects of various parameters on the antenna characteristics are examined. An antenna, as an design example for the proposed antenna, is designed for the operation in the frequency band of 470-806 MHz for terrestrial DTV. The optimized antenna is fabricated on an FR4 substrate and tested experimentally to verify the results of this study.

  • PDF