• Title/Summary/Keyword: Low water level sensor

Search Result 31, Processing Time 0.023 seconds

Development of experimental water level measuring device using an Arduino and an ultrasonic sensor (아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발)

  • Yoo, Moonsung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.143-147
    • /
    • 2018
  • Water levels are measured in various fields such as sewage treatment plants, water treatment plants, rivers, dams, factory storages' tanks. Ultrasonic instruments for water level measurement are expensive and are used for industrial field. Rapid advances in electronics have made it possible to build a wide variety of measurement, monitoring and control functions at low cost. This study was started to make ultrasonic level measurement system at low price. The system was constructed with an Arduino, an ultrasonic sensor and a temperature sensor for use in the experiment. The ultrasonic sensor measures the time from the sensor to the liquid surface. The temperature sensor measures the atmospheric temperature and improves the accuracy of the ultrasonic distance measurement by correcting the sound speed. Arduino controls measurements and calculates the water level. All components of the system are assembled into a device holder. Experiments with this system show that the water level measured by the system is very close to the actual value. This system is also inexpensive and easy to install and maintain, making it suitable for laboratory use.

A Study on the Implementation of Intelligent Diagnosis System for Motor Pump (모터펌프의 지능형 진단시스템 구현에 관한 연구)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.87-91
    • /
    • 2019
  • The diagnosis of the failure for the existing electrical facilities was based on regular preventive maintenance, but this preventive maintenance was limited in preventing a lot of cost loss and sudden system failure. To overcome these shortcomings, fault prediction and diagnostic techniques are critical to increasing system reliability by monitoring electrical installations in real time and detecting abnormal conditions in the facility early. As the performance and quality deterioration problem occurs frequently due to the increase in the number of users of the motor pump, the purpose is to build an intelligent control system that can control the motor pump to maximize the performance and to improve the quality and reliability. To this end, a vibration sensor, temperature sensor, pressure sensor, and low water level sensor are used to detect vibrations, temperatures, pressures, and low water levels that can occur in the motor pump, and to build a system that can identify and diagnose information to users in real time.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

Fabrication of Water Level Limit Sensor Utilizing Acoustic Impedance Matching (음향임피던스 정합을 이용한 액면레벨 Limit센서의 구현)

  • Kim, Cheol-Han;Lee, Su-Ho;SaGong, Geon;Lee, Jun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1870-1872
    • /
    • 2005
  • In this study, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed to be able to check it out a change of water-level. 2 PZT resonators with the same property are bonded directly on the polyethylene plate. One resonator is for transmitter as an ultrasonic transducer, the other one is for receiver. In this case, a polyethylene plate will operate as an acoustic guider to transmit a transverse wave between 2 PZT resonators in air. While in the water, a polyethylene plate having a similar acoustic impedance with the water will be emitted an acoustic energy into the water as a longitudinal wave. According to this mechanism, there was a wide difference of acoustic signal output between underwater and in air. As a summary, this proposed level limit sensor could be used as a strong candidate with low cost and more stable one.

  • PDF

Applicability of Satellite SAR Imagery for Estimating Reservoir Storage (저수지 저수량 추정을 위한 위성 SAR 자료의 활용성)

  • Jang, Min-Won;Lee, Hyeon-Jeong;Kim, Yi-Hyun;Hong, Suk-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.7-16
    • /
    • 2011
  • This study discussed the applicability of satellite SAR (Synthetic Aperture Radar) imagery with regard to reservoir monitoring, and tried the extraction of reservoir storage from multi-temporal C-band RADARSAT-1 SAR backscattering images of Yedang and Goongpyeong agricultural reservoirs, acquired from May to October 2005. SAR technology has been advanced as a complementary and alternative approach to optical remote sensing and in-situ measurement. Water bodies in SAR imagery represent low brightness induced by low backscattering, and reservoir storage can be derived from the backscatter contrast with the level-area-volume relationship of each reservoir. The threshold segmentation over the routine preprocessing of SAR images such as speckle reduction and low-pass filtering concluded a significant correlation between the SAR-derived reservoir storage and the observation record in spite of the considerable disagreement. The result showed up critical limitations for adopting SAR data to reservoir monitoring as follows: the inappropriate specifications of SAR data, the unreliable rating curve of reservoir, the lack of climatic information such as wind and precipitation, the interruption of inside and neighboring land cover, and so on. Furthermore, better accuracy of SAR-based reservoir monitoring could be expected through different alternatives such as multi-sensor image fusion, water level measurement with altimeters or interferometry, etc.

Development of a Sensorless Deep Well Pump Multi-function Controller using Current Detection Method (전류검출 방식의 심정 펌프 센서리스형 다기능 컨트롤러 개발)

  • Lee, In-Jae;Basnet, Barun;Chun, Hyun-Jun;Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1149-1154
    • /
    • 2017
  • In this paper, we propose a sensorless multi-function controller applicable for deep well water pumps using current detection method. The proposed system overcomes various drawbacks of existing sensored system and additional features like Over current protection function due to overload, Under current protection function for idling at low water level and Relay function for starting single phase motors and acts as a level indicator to detect water lever in real time by the current detection method. A prototype of the multi-function controller system is designed and all of its functions are tested in the laboratory. The application of the proposed controller ensures reduction in the power consumption and maintenance cost in the facilities like water and septic tanks, drainage and waste water system, oil and chemical tanks where deep well pumps are used.

A Study on improvement of plating equipment for fire prevention (도금 공장의 화재 예방을 위한 도금장비 개선에 관한 연구)

  • Kim, Sung-Jae;Kim, Sung-Gon;Yoo, Woo-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.35-42
    • /
    • 2017
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt $100{\Omega}$ sensor which can detect until $600^{\circ}C$. When the bath temperature sensor detects over $60^{\circ}C$ or the Teflon heater sensor detects over $240^{\circ}C$ they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of $240^{\circ}C$ by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Real-Time Soil Humidity Monitoring Based on Sensor Network Using IoT (IoT를 사용한 센서 네트워크 기반의 실시간 토양 습도 모니터링)

  • Kim, Kyeong Heon;Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.459-465
    • /
    • 2022
  • This paper reports a method to use a wireless sensor network deployed in the field to real-time monitor soil moisture, warning when the moisture level reaches a specific value, and wirelessly controlling an additional device (LED or water supply system, etc.). In addition, we report all processes related to wireless irrigation system, including field deployment of sensors, real-time monitoring using a smartphone, data calibration, and control of additional devices deployed in the field by smartphone. A commercially available open-source Internet of Things (IoT) platform, NodeMCU, was used, which was combined with a 9V battery, LED and soil humidity sensor to be integrated into a portable prototype. The IoT-based soil humidity sensor prototype deployed in the field was installed next to a tree for on-site demonstration for the measurement of soil humidity in real-time for about 30 hours, and the measured data was successfully transmitted to a smartphone via Wifi. The measurement data were automatically transmitted via e-mail in the form of a text file, stored on the web, followed by analyses and calibrations. The user can check the humidity of the soil real-time through a personal smartphone. When the humidity of a soil reached a specific value, an additional device, an LED device, placed in the field was successfully controlled through the smartphone. This LED can be easily replaced by other electronic devices such as water supplies, which can also be controlled by smartphones. These results show that farmers can not only monitor the condition of the field real-time through a sensor monitoring system manufactured simply at a low cost but also control additional devices such as irrigation facilities from a distance, thereby reducing unnecessary energy consumption and helping improve agricultural productivity.

Design and Implementation of Remote Monitoring System for Underground Low Voltage Handhole Using Zigbee Communication (지그비 통신을 이용한 지중저압접속함 원격 모니터링 시스템 설계 및 구현)

  • Weon, La-Kyoung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.3
    • /
    • pp.58-67
    • /
    • 2019
  • The low-voltage connection box used as a low-voltage transmission line of KEPCO is intended to branch or connect to an underground line. In comparison with the utility considering the aesthetics of the distance, and safety measures are needed. In this paper, temperature and humidity, $CO_2$, water level, acceleration, and vibration sensor are installed inside the underground low voltage handhole, and the sensor data is transmitted to the ground using the Zigbee module. Antenna (Bolted Antenna) for communication with the ground was proposed and the data reception through it was confirmed. In the LF mode and the HEX mode, the transmitted data was confirmed to be a perfect reception success rate. In the case of the bolted antenna, the difference between the ground state and the underwater state was observed as a result of the experiment in the environmental environment. However, It was judged that reception sensitivity was sufficient for communication. The received data could be confirmed through PC based GUI.