• Title/Summary/Keyword: Low shrinkage concrete

Search Result 147, Processing Time 0.021 seconds

Performance review of ultra-low shrinkage concrete by field application (현장적용을 통한 초 저수축 콘크리트의 성능 검토)

  • Kim, Kang-Min;Lee, Hyun-Seung;Seo, Tae-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.211-212
    • /
    • 2022
  • In this study, the cracking control performance of ultra-low shrinkage concrete was investigated by the field application. As a result, drying shrinkage crack occurred in normal concrete wall, but no crack occurred in ultra-low shrinkage concrete wall. It is determined that the drying shrinkage crack control effect of the ultra-low shrinkage concrete is excellent.

  • PDF

An Experimental Study on the Shrinkage Properties of Ultra-Low Shrinkage Concrete (초 저수축 콘크리트의 수축특성에 관한 실험적 연구)

  • Seo, Tae-Seok;Kim, Kang-Min;Lee, Hyun-Seunh
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.148-149
    • /
    • 2021
  • In Japan, ultra-low shrinkage concrete has been developed and commercialized to control drying shrinkage cracks to the limit. However, in the case of South Korea, the study on this technology has not yet been conducted in earnest. Therefore, the study was conducted for the development of ultra-low shrinkage concrete to control the drying shrinkage crack of concrete to the limit, and in this study, after determining the mixture of ultra-low shrinkage concrete, a wall type mock-up specimen was produced to observe the shrinkage behavior of ultra-low shrinkage concrete.

  • PDF

Analysis of Crack Control Effect of Ultra-low Shrinkage Concrete through Wall Mock-up Test (벽체 실물대부재실험을 통한 초 저수축 콘크리트의 균열제어 효과 분석)

  • Seo, Tae-Seok;Lee, Hyun-Seung;Kim, Kang-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • Ultra-low shrinkage concrete is very effective for securing the quality and appearance of a concrete structure because it can control the drying shrinkage cracks of the concrete structure to within a certain limit. In this study, with the purpose of commercializing ultra-low shrinkage concrete, the optimal amount of expansive agent and shrinkage reducing agent was determined through a lab test, and a concrete wall mock-up test was conducted to examine the shrinkage properties and crack control effects of ultra-low shrinkage concrete. As a result, it was confirmed that there was little drying shrinkage deformation in the wall specimen, and furthermore that no cracks were generated.

Effect of Autogenous Shrinkage on Shrinkage behavior in High Stength Concrete (자기건조수축을 고려한 고강도 콘크리트의 수축변형 특징에 관한 연구)

  • Paek, Nak-Seung;Cha, Soo-Won;Lee, Seong-Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.429-432
    • /
    • 2006
  • The shrinkage mechanism of high strength concrete is different from that of normal concrete. The shrinkage of normal concrete is subjected to evaporate moisture in concrete, but most shrinkage in high strength concrete is caused by chemical reaction. To analyze shrinkage of concrete exactly, it is necessary to divide drying shrinkage with autogenous shrinkage in terms of degree of hydration, especially in concrete with low W/C ratio. The proposed method can provide a rational basis for prediction of shrinkage in high strength concrete structure.

  • PDF

Differential Drying Shrinkage and Autogenous Shrinkage of Concrete at Early Ages (초기재령 콘크리트의 부등건조수축과 자기수축에 관한 연구)

  • 김진근;이칠성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.309-314
    • /
    • 1998
  • The moisture diffusion and self-desiccation cause the differential drying shrinkage and autogenous shrinkage at early ages, respecitvely. Thus total shrinkage strain includes the differential drying shrinkage and self-desiccation shrinkage. Thus in this study the shrinkage strain was measured at various positions in the exposed concrete and in the sealed concrete the self-desiccation shrinkage was measured. In low-strength concrete, the differential drying shrinkage increases very rapidly, but self-desiccation shrinkage is very small. But high-strength concrete shows the reverse result. And the analytical results for differential drying shrinkage were in good agreement with the test results.

  • PDF

Evaluation of Properties of Ultra-Low Shrinkage Concrete for Omission of Paking Lot Floor Joint (주차장 바닥 줄눈 생략을 위한 초저수축 콘크리트 물성 평가)

  • Kim, Kang-Min;Lee, Hyun-Seung;Yoon, Seob;Seo, Tae-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.194-195
    • /
    • 2022
  • The jointing of unsupported concrete on the parking lot floor is a process for cracking and stress relief due to concrete drying shrinkage and restraint, but curling occurs due to long-term drying shrinkage after the initial age. will be lowered Therefore, by using an expansion material and a shrinkage reducing agent, the dry shrinkage of concrete is realized to 200 με or less.

  • PDF

Autogenous Shrinkage of Concrete Containing Blast-Furnace Slag (고로 슬래그를 함유한 콘크리트의 자기 수축)

  • 이회근;권기헌;이광명;김규용;손유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.417-420
    • /
    • 2003
  • Concrete with low water to binder ratio (W/B) is prone to large autogenous shrinkage. Early age cracking of concrete would be caused by tensile stress induced by large autogenous shrinkage under restrained condition. Therefore, it is necessary to measure autogenous shrinkage to control the early age cracking of concrete. An objective of this study is to investigate the effects of W/B and blast furnace slag (BFS) on autogenous shrinkage of concrete. Autogenous shrinkage of concrete with various W/B ranging from 0.42 to 0.27 and BFS contents of 0, 30 and 50% were measured. Test results show that the autogenous shrinkage of concrete increases as the W/B decreases, and all BFS concretes showed larger autogenous shrinkage than OPC concretes with the same W/B. Moreover, the higher BFS content, the larger autogenous shrinkage.

  • PDF

A Field Application of Non-shrinkage Concrete Pavement using CSA Expansive Additive (CSA계 팽창재를 사용한 무수축콘크리트의 도로포장 현장적용 사례연구)

  • 이재한;송경환;최일규;김창률;민경소
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.183-188
    • /
    • 1997
  • From a viewpoint of construction cost and preserving management of pavement, a policy of domestic pavement was gradually spreaded concrete pavement rather than asphalt. But the use of concrete with ordinary portland cement has shortages, such as dry-shrinkage, low flexural strength, etc. In order to overcome these problems, the concrete pavement using CSA expansive additive (Non-Shrinkage Cement) was studied and carried out the fie이 application. As the results, we find out Non-Shrinkage Cement that was distinguished in short-term construction by increasing flexural strength, shrinkage compensating and low-heat evaluation compared with OPC concrete.

  • PDF

An Experimental Study on Shrinkage of High Strength Concrete with Mineral Admixture (혼화재 사용에 따른 고강도 콘크리트의 수축에 관한 실험적 연구)

  • Lee, Young-Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • The effects of additive and shrinkage reducing agent on the drying and autogenous shrinkage of high strength concrete are investigated in this study. As results, when the ratio of W/B(low water to binder ratio) increase, the compressive strength is decreased. Comparing with PC(portland cement) concrete, the strength is 2.8%, 3.2% and 3.8% lower respectively than that of PC when concrete mixing ratio is 0.2%, 0.3% and 0.4% in 28 days curing. Drying shrinkage strain of PC concrete showed $-650{\times}10^{-6}$ in 91 days curing. When SR(shrinkage reducing agent) of 0.2%, 0.3% and 0.4% is mixed, the drying shrinkage strains are 21%, 34% and 41% lower than those of PC in 91 days curing. Autogenous shrinkage strain of PC concrete appeared $-480{\times}10^{-6}$ in 56 days curing. When SR of 0.2%, 0.3% and 0.4% is mixed, the autogenous drying shrinkage strain are 12.5%, 19.8% and 33.3% lower than those of PC in 56 days curing. In cases of using the mineral and shrinkage agent or only using a shrinkage reducing agent also appeared same reducing effects for drying shrinkage and autogenous shrinkage.

  • PDF

Preparation and Properties of Low-shrinkage Polymer Concretes (저수축형 폴리머 콘크리트의 제조 및 물리.역학적 특성)

  • 황진하;연구석;이윤수;이기원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.321-326
    • /
    • 2000
  • Many different polymer based concrete materials are known today, but the large setting or hardening shrinkage of polymer concrete is a problem to overcome in their practical applications. The setting shrinkage reaches about five to ren times he drying shrinkage ordinary cement concrete, i.e, 50 to $60\times10^{-4}$. This paper deals with a reduction in the hardening shrinkage of unsaturated polyester resin concrete which is treated with respect to shrinkage-reducing agent content, S/a ratio and catalyst content, and tested for length change during hardening, and flexural and compressive strength. It is show that the change of shrinkage-reducing agent content and S/a ratio affected the length change of the unsaturated polyester resin concrete during hardening.

  • PDF