• Title/Summary/Keyword: Low rise facility

Search Result 46, Processing Time 0.022 seconds

A Study to Set up Guideline for Public Facilities as Infrastructure of Low-rise Residential Community in Seoul (서울 저층주거 밀집지역 공공생활지원시설 설정방향에 관한 연구)

  • Shin, Jee-Hun;Lee, Na-Rae;Kim, Jong-Pil;Kim, Donyun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.2
    • /
    • pp.127-137
    • /
    • 2019
  • Low-rise residential community is the most popular type (51%) of residential neighborhoods in Seoul. Currently, there is a shortage of public facilities needed for living conditions and the quality of life in low-rise residential areas. This study defines 'public facility' as infrastructure to improve the living environment and used by residents jointly in low-rise residential areas. In this regard, this study analyzes current legal and institutional standards, latest trends in public facility of apartments, and residents' demand and satisfaction level in order to find out the criteria for installation of priority public facilities. As a result, the essential facility basically conforms to the number of household which is the standard of the facility supply in apartment. However, considering the limitations on the accessibility due to low density, it should consider two standards at the same time: the number of household and distance (radius of neighborhood). In conclusion, it is necessary to install legally prescribed facilities according to the number of household and distance: 500 households facilities in 250m radius neighborhood and 1,000 households facilities in 400m radius neighborhood. Also, considering the reality of low-rise residential area, it is necessary to integrate some facilities that can be functionally linked to improve level of utility and efficiency of operation and management. It is expected that the output of this study can be applied to institutionalize of the legal basis for the public facility of low-rise residential community.

Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings

  • Gol-Zaroudi, Hamzeh;Aly, Aly-Mousaad
    • Wind and Structures
    • /
    • v.25 no.3
    • /
    • pp.233-259
    • /
    • 2017
  • Investigations on simulated near-surface atmospheric boundary layer (ABL) in an open-jet facility are carried out by conducting experimental tests on small-scale models of low-rise buildings. The objectives of the current study are: (1) to determine the optimal location of test buildings from the exit of the open-jet facility, and (2) to investigate the scale effect on the aerodynamic pressure characteristics. Based on the results, the newly built open-jet facility is well capable of producing mean wind speed and turbulence profiles representing open-terrain conditions. The results show that the proximity of the test model to the open-jet governs the length of the separation bubble as well as the peak roof pressures. However, test models placed at a horizontal distance of 2.5H (H is height of the wind field) from the exit of the open-jet, with a width that is half the width of the wind field and a length of 1H, have consistent mean and peak pressure coefficients when compared with available results from wind tunnel testing. In addition, testing models with as large as 16% blockage ratio is feasible within the open-jet facility. This reveals the importance of open-jet facilities as a robust tool to alleviate the scale restrictions involved in physical investigations of flow pattern around civil engineering structures. The results and findings of this study are useful for putting forward recommendations and guidelines for testing protocols at open-jet facilities, eventually helping the progress of enhanced standard provisions on the design of low-rise buildings for wind.

Partial turbulence simulation and aerodynamic pressures validation for an open-jet testing facility

  • Fu, Tuan-Chun;Chowdhury, Arindam Gan;Bitsuamlak, Girma;Baheru, Thomas
    • Wind and Structures
    • /
    • v.19 no.1
    • /
    • pp.15-33
    • /
    • 2014
  • This paper describes partial turbulence simulation and validation of the aerodynamic pressures on building models for an open-jet small-scale 12-Fan Wall of Wind (WOW) facility against their counterparts in a boundary-layer wind tunnel. The wind characteristics pertained to the Atmospheric Boundary Layer (ABL) mean wind speed profile and turbulent fluctuations simulated in the facility. Both in the wind tunnel and the small-scale 12-Fan WOW these wind characteristics were produced by using spires and roughness elements. It is emphasized in the paper that proper spectral density parameterization is required to simulate turbulent fluctuations correctly. Partial turbulence considering only high frequency part of the turbulent fluctuations spectrum was simulated in the small-scale 12-Fan WOW. For the validation of aerodynamic pressures a series of tests were conducted in both wind tunnel and the small-scale 12-fan WOW facilities on low-rise buildings including two gable roof and two hip roof buildings with two different slopes. Testing was performed to investigate the mean and peak pressure coefficients at various locations on the roofs including near the corners, edges, ridge and hip lines. The pressure coefficients comparisons showed that open-jet testing facility flows with partial simulations of ABL spectrum are capable of inducing pressures on low-rise buildings that reasonably agree with their boundary-layer wind tunnel counterparts.

A Study on the Improvement of the Refuge safety area in High-rise Buildings Type (초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

The Analysis of a Neighborhood Center in the Urban Low-rise Residential Areas (도시 저층주거지의 생활권 중심 분석)

  • Ku, Mee-Kyung;Yang, Woo-Hyun
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.19-29
    • /
    • 2016
  • As a lifeway and social change, the neighborhood build up around elementary school based on Perry's Neighbourhood Unit becomes change. Elementary School does not function as a center of residents' activity or community any longer. Activities occurred near the school move to the community streets that many facilities are distributed to, while utilization of facilities near schools becomes lower. On the bases of the current states, this study aims to draw a practical neighborhood center of residential areas by case study. The research is being mainly about low-rise residential areas in Seoul which includes one elementary school at least. In order to deduct the center of neighborhood, the survey takes two steps. At the preliminary survey, conduct the observation and do an interview to investigate awareness and actual status. Also to analyze practical center, do a main survey about land value, pedestrian volume, distribution of public transit and facility density. The research result shows that there is another activated center street not nearby elementary school in every case. This study assumes that the neighborhood center is not limited around elementary school and could variously build up by circumstances. It has significance that we present a question about the traditional theory and also could be references of the future city maintenance in the long term.

Internal pressure in a low-rise building with existing envelope openings and sudden breaching

  • Tecle, Amanuel S.;Bitsuamlak, Girma T.;Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.16 no.1
    • /
    • pp.25-46
    • /
    • 2013
  • This paper presents a boundary-layer wind tunnel (BLWT) study on the effect of variable dominant openings on steady and transient responses of wind-induced internal pressure in a low-rise building. The paper presents a parametric study focusing on differences and similarities between transient and steady-state responses, the effects of size and locations of dominant openings and vent openings, and the effects of wind angle of attack. In addition, the necessity of internal volume correction during sudden breaching, i.e., a transient response experiment was investigated. A comparison of the BLWT data with ASCE 7-2010, as well as with limited large-scale data obtained at a 'Wall of Wind' facility, is presented.

A Study on Post Occupancy Evaluation of Block Housing -Focused on The Block Housing in Eunpyeong New Town, in Korea - (가구형 집합주택의 거주후평가 연구 - 은평뉴타운을 중심으로 -)

  • Park, Joong-Hyun;Choo, Sun-Kyong;Kang, Boo-Seong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.73-77
    • /
    • 2009
  • The block housing type is coming to fore as a 'low-rise high-density housing type', which can resolve the all sorts of problem caused in Korea apartment housing complex and single-detached residental area in terms of livability, urbanity, and community. To analyze the characteristics of the block housing, the block housing in Eunpyeong New Town, in Korea was analyzed as a sample for post occupancy evaluation. The analysis show that the block housing is useful low-rise and high-density housing type, which ensures the livability as well as the urbanity and community. In details the analysis also shows the user satisfaction from the perspective of living and facility use within the block housing and individual unit.

  • PDF

AN ASSESSMENT SYSTEM OF ECO-FRIENDLINESS OF CONSTRUCTED FACILITY IN THE DESIGN PHASE USING VALUE ENGINEERING

  • Byung-Soo, Kim;Dong-Eun, Lee;Suk-Hyun, Kwon;Min-Kwon, Choe
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1625-1629
    • /
    • 2009
  • The new paradigm called 'Low Carbon Green Growth' involved in reducing greenhouse gas is on the rise as a critical issue worldwide. The essential of Kyoto protocol issued in 1997 is to achieve the sustainable economic growth environments by converting existing production system to eco-friendly one. The protocol imposes the liability to reduce greenhouse gas to the countries joined to it. The paradigm is directly involved in the energy consumption and environmental pollution caused by construction activities. Value Engineering which are mainly applied in the design phase in practice is a measure to improve the value of a constructed facility by analyzing and/or appraising the functions and costs of it. However, an appropriate method which assesses eco-friendliness of constructed facility has not been propose by researchers. This paper proposes a method which assesses the performance involved in eco-friendliness of constructed facility using Value Engineering (VE) in the design phase. The method estimates the environmental cost relative to the amounts of energy consumption and environmental pollution occurred over the entire project life cycle. The database called "Life Cycle Inventory DB", which stores information about the amounts of environmental pollution, is used. The algorithm which retrieves the amounts of environmental pollutions from the DB and converts them into environmental costs is developed. The algorithm is implemented into a system which quantifies the eco-friendliness of constructed facility in the design phase using VE.

  • PDF

A Basic Study on the Application of Modular Construction - Focused on the Analysis of Case Study - (모듈러 건축의 현황과 활용에 관한 기초연구 - 사례조사 분석을 중심으로 -)

  • Kim, Jae-Young;Lee, Jong-Kuk
    • Journal of the Korean housing association
    • /
    • v.25 no.4
    • /
    • pp.39-46
    • /
    • 2014
  • This research was for the investigation and analysis of the illustration of modular construction application which is different use by each school facility since modular construction related examples are rare in domestic situation, and it has a limitation because of its being basic research material for generating the basic form of modular construction. The research results are as followings. First, in case of school facility from illustration investigation results, module measurement of class modulation is as similar as $3m{\times}10m$, but in resident facility the planning of more flexible plane shape can be possible since modules of 6 cases are free and various, and facade form of various types can be appeared by combination of module unit. Second, as a result of the generated characteristics in compared analysis of representative examples, school facilities were highly indicated for movability and duration reduction areas, and the flexibility, economic efficiency, and environment-friendliness was indicated low relatively. Third, the basic planning types of modular construction can be largely divided into layered type, horizontal (straightway) type, and compound type. The layered type has a short traffic line and facility system and is appropriate for the low-rise form unless separate construction method is used since it is susceptible to load. The horizontal type is advantageous for securing an opening since it has wide extent in light but has a long traffic line and facility system. Finally, the compound type can be possible for planning of various forms but needs the combination of various unit modules and traffic line and facility plan for it can be difficult.

A Development Model of Korean Urban Neighborhood: - focusing on the Neighborhood Growth and the Educational Facility - (한국 도시동네의 형태변화 모델 - 동네의 성장과 교육시설과의 관계를 중심으로 -)

  • Han, GwangYa;Kim, Min-ji;Ha, Sung-Hyun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.28 no.6
    • /
    • pp.15-28
    • /
    • 2021
  • This study aims to propose a hypothetical urban neighborhood, HanGyo-dong, which is a model for understanding the relationship between the neighborhood change and educational facilities. Three issue layers of the model derived from preceding case studies are: establishment, relocation and redevelopment of educational facilities; formation and redevelopment of adjacent residential areas; and growth of neighborhood commercial cores. The neighborhood changes observed through HanGyo-dong include (1) the formation of educational base and commercial activities along the stream, (2) the growth of student and intellectual community and the installment of public transportation nodes, and (3) the relocation of schools and hospitals followed by a series of redevelopments of single family house into multi-family housing of low-rise residence and high rise apartment complex. The findings call for the collaborative practice of educational administration and neighborhood planning regarding how educational facilities, which were the tool for urban expansion policy, will contribute to the development of the neighborhood's identity as a localized hub.