• Title/Summary/Keyword: Low resistance measurement

Search Result 261, Processing Time 0.03 seconds

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

Precise Measurement of High Current Shunt Resistance (대전류 분류기 저항의 정밀측정)

  • Kim K.-T.;Han K.-S.;Kwon S.-W.;Kim M.-S.;Jeong J.Y.;Kim I.S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.403-406
    • /
    • 2005
  • Precise measurement of extremely low resistance shunt is important for characterization and calibration of high current instruments. We tested resistance measurement method for extremely high current shunt (up to 140 kA), where resistance is determined by precise measurement of voltage drop at 10 A test current in the frequency range of 40 Hz to 10 kHz. For the extremely low ac voltage to be precisely measured, a verification of the measurement method was also carried, where the inherent noise is systematically evaluated. The measurement uncertainty was estimated to be $1\;\%\;at\;95\;\%$ confidence level (k=2) for about 50 $\mu\Omega$.

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

4-Terminal Measurement Technique of 2-Terminal Decade Resistor (2단자 계단식 저항기의 4단자 측정기술)

  • Lee, Sang-Hwa;Jang, Seok-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1798-1802
    • /
    • 2013
  • We present a technique for measuring low resistance ranges of a decade resistor with a 4-Terminal connection. With the technique the accuracy of 0.8 % was obtained for a 1 $m{\Omega}$ resistance of the decade resistor. We suggested a proper pattern 4-Terminal measurement results with several 4-Terminal pattern and adapters. Additionally, we should that precise measurements for low resistance can be made usung a digital multimeter(DMM) only.

The Tunneling Effect at Semiconductor Interfaces by Hall Measurement (홀측정을 이용한 ZTO 반도체 박막계면에서의 터널링 효과)

  • Oh, Teresa
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.408-411
    • /
    • 2019
  • ZTO/n-Si thin film is produced to investigate tunneling phenomena by interface characteristics by the depletion layer. For diversity of the depletion layer, the thin film of ZTO is heat treated after deposition, and the gpolarization is found to change depending on the heat treatment temperature and capacitance. The higher the heat treatment temperature is, the higher the capacitance is, because more charges are formed, the highest at $150^{\circ}C$. The capacitance decreases at $200^{\circ}C$ ZTO heat treated at $150^{\circ}C$ shows tunneling phenomena, with low non-resistance and reduced charge concentration. When the carrier concentration is low and the resistance is low, the depletion layer has an increased potential barrier, which results in a tunneling phenomenon, which results in an increase in current. However, the ZTO thin film with high charge or high resistance shows a Schottky junction feature. The reason for the great capacitance increase is the increased current due to tunneling in the depletion layer.

Uncertainty in Potentiodynamic Polarization Resistance Measurement (동전위 분극저항 측정에서의 불확도)

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

Compensation of Resistance Variation due to Temperature in Voltage Measurement System (온도에 따른 저항 변화를 보상한 전압 측정 방법)

  • Min, Sang-Jun;Kim, Jin-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1174-1177
    • /
    • 2012
  • In voltage measurement by using voltage divider with series resistors, error is generated caused by the variation of resistance. In order to reduce these errors, the hardware cost tends to increase in the previous works. In the proposed method, three resistors are used for the voltage divider of which the organization is adjusted by using switches. Three voltages are measured and the ratio of resistance is calculated based on the measured voltages. Since the resistance ratio is calculated by measuring voltages and additional hardware cost is minimal, the voltage can be measured with high accuracy and low cost. Experimental results show that the mean absolute error is 12.1 mV when the input voltage ranges from 5 V to 50 V.

A measuring Method of Ground Resistance for Energized Power Systems (운전중인 전력설비의 접지저항 측정방법)

  • 이복희;김성원;엄주홍;이승칠
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.77-81
    • /
    • 2000
  • The purpose of this paper is to describe a new measuring method of ground resistance for the grounding system in energized power equipment and substations. It is very difficult to measure the accurate ground resistance in energized power equipment and substations because of the noise conducted from all external connections to the grounding system and harmonics components caused by unbalanced loads and overloads. The ground resistance that is measured with existing methods includes not only the effect of desired signals but also noise components for the measurement period in grounding system. The measured value of ground resistance can entirely be different from actual value. In this paper, to eliminate 60[Hz] power system interference and harmonic components the low-pass filter method was used in the measurement of ground resistance.

  • PDF

Measurement of HTS tapes Properties under Over current condition (고온초전도선재의 과전류 통전특성 측정)

  • 이광연;임형우;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.263-266
    • /
    • 2002
  • Rises of temperature and resistance are observed in HTS tapes under over current condition. In this paper, we measured HTS tapes properties under low-over current condition with a little temperature rise as well as high-over current condition with a large temperature rise. According to the results of measurement, rises of temperature and resistance strongly depend on insulation level and duration of over current condition.

  • PDF