• 제목/요약/키워드: Low order controller

검색결과 298건 처리시간 0.03초

비최소 위상 플랜트에서 LQ-servo 방법 (LQ-servo method for non-minimum phase plants)

  • 서병설;장태우
    • 전자공학회논문지B
    • /
    • 제33B권3호
    • /
    • pp.9-16
    • /
    • 1996
  • LQ-servo is a robustness guaranteed multivariable controller design method based on the LQR structure to improve command following with output feedback. in this paper we introduce a weighting factor on the low frequency part of the state weighting matrix in the performance index in order to increase the low frequency gain of loop transfer function matrix T(s) in the loop shaping design method.

  • PDF

Employing Multi-Phase DG Sources as Active Power Filters, Using Fuzzy Logic Controller

  • Ghadimi, Ali Asghar;Ebadi, Mazdak
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1329-1337
    • /
    • 2015
  • By placing distributed generation power sources beside a big nonlinear load, these sources can be used as a power quality enhancer, while injecting some active power to the network. In this paper, a new scheme to use the distributed generation power source in both operation modes is presented. In this scheme, a fuzzy controller is added to adjust the optimal set point of inverter between compensating mode and maximum active power injection mode, which works based on the harmonic content of the nonlinear load. As the high order current harmonics can be easily rejected using passive filters, the DG is used to compensate the low order harmonics of the load current. Multilevel transformerless cascade inverters are preferred in such utilization, as they have more flexibility in current/voltage waveform. The proposed scheme is simulated in MATLAB/SIMULINK to evaluate the circuit performance. Then, a 1kw single phase prototype of the circuit is used for experimental evaluation of the paper. Both simulative and experimental results prove that such a circuit can inject a well-controlled current with desired harmonics and THD, while having a smaller switching frequency and better efficiency, related to previous 3-phase inverter schemes in the literature.

마이크로컨트롤러를 이용한 완전 이식형 인공중이용 저전력 음성 신호처리 및 제어 모듈의 설계 (Design of a Low Power Voice Signal Processing and Control Module using a $\mu$-controller for Totally Implantable Middle Ear system)

  • 강호경;정의성;임형규;박일용;윤영호;김민규;송병섭;조진호
    • 전자공학회논문지SC
    • /
    • 제41권5호
    • /
    • pp.49-56
    • /
    • 2004
  • 완전 이식형 인공중이 시스템을 위한 음성 신호처리 및 제어 모듈을 소형 마이크로컨트롤러를 사용하여 저전력형으로 설계 하였다 설계된 모듈은 입력되는 음성신호를 난청자의 역치에 맞추어 이득을 조정하는 등의 신호처리를 수행함과 동시에 체내 이식부의 제어를 수행하게 된다. 설계된 마이크로컨트롤러는 전원이 켜지면 사용자의 청력 손실에 맞추어서 주파수별로 차등 되는 이득을 주도록 실시간으로 음성신호를 처리하게 된다. 그러나 체외에서 제어신호가 입력될 경우 수신된 제어 신호에 의해 마이크로컨트롤러는 인터럽트 서브루틴을 수행하여 전원 제어, 볼륨 조절과 같은 제어 명령을 수행한 후 다시 음성 신호를 처리하도록 하였다. 설계된 모듈을 구현한 후 구현된 시스템의 동작을 실험을 통하여 확인하였다.

대형 저속 디젤기관의 속도제어를 위한 로바스트 서보 제어기 설계 (Design of Robust Servo Controller for Large Size Low Speed Diesel Engines)

  • 정병건;양주호;변정환
    • 수산해양기술연구
    • /
    • 제33권1호
    • /
    • pp.46-58
    • /
    • 1997
  • The energy saving is one of the most important factors for profit in marine transportation. In order to reduce the fuel oil consumtion the ship's propulsion efficiency must be increased as possible. The propulsion efficiency depends upon a combination of an engine and a propeller. The propeller has better efficiency as lower rotational speed. This situation led the engine manufacturers to design the engine that has low speed, long stroke and a small number of cylinders. Consequently, the variation of rotational torque became larger than before because of the longer delay-time in fuel oil injection process and an increased output per cylinder. As this new trends the conventional mechanical-hydrualic governors for engine speed control have been replaced by digital speed controllers which adopted the PID control or the optimal control algorithm. But these control algorithms have not enough robustness to suppress the variation of the delay-time and the parameter perturbation. In this paper we consider the delay-time and the perturbation of engine parameters as the modeling uncetainties. Next we design the robust servo controller which has zero offset in steady state engine speed, based on H sub($\infty$) control theory. The validity of the controller was investigated through the response simulation. We used a personal computer and an analog computer as the digital controller and the engine (plant) part respectively. And, we could certify that the designed controller maintains its robust servo performance even though the engine parameters may vary.

  • PDF

저역통과 LC필터를 가진 전브리지형 인버터로 구동되는 3상유동전동기의 속도제어 시스템에 관한 연구 (A Study on the Speed Control System of a 3 phase Induction Motor driven by the Full Bridge Inverter with a Low Pass LC Filter)

  • 박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.538-550
    • /
    • 1998
  • The variable frequency and variable voltage AC source made by a conventional inverter which is composed of power semi-conductors includes much noises in sine wave due to high frequency switching of DC source. In this paper the 3rd low pass LC filter for a variable speed 3 phase induction motor driven by a full bridge inverter is introduced to solve the EMI problem by serious noise current. The utility of a modified 3rd order Butterworth LC filter is confirmed through FFT analysis of sine waves and noiseless ACsource can be obtained by the proposed LC filter. The speed of a 3 phase induction motor driven by a full bridge inverter with a LC filter is satisfactorily controlled by a digital PID controller under the condition of stepwise load and setpoint changes.

  • PDF

정현파 출력 필터를 가지는 3상 PWM 인버터 제어 기법 (A Novel Control Algorithm of a Three-phase PWM Inverter with LC Filter)

  • 김광섭;현동석
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.239-246
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of second-order low pass filter(LPF), which has a zero damping ratio. A simple method of implementing second-order LPF with damping ratio is to add a resistor in an LC circuit. However, in a real power system, adopting damping resistors is impractical because it results in losses proportional to the square of the current flowing through the resistors. Instead of inserting resistors, the proposed control strategy utilizes the measured capacitor voltages to control the oscillation of LC circuit. The overall transfer function of the proposed method is the same as a second-order LPF, and its damping ratio is controllable via control variables. The current controller can have overshoots caused by LC filter. Improved current controller is implemented by an equivalent second-order of LC filter. A 7.5 kVA PWM converter and a PWM inverter with a 5.5 kW induction motor are set up to verify the proposed control algorithm. Test waveforms are also presented to verify the proposed LC filter control algorithm.

일반화된 예측제어에 의한 가압경수형 원자로의 부하추종 출력제어에 관한 연구 (Generalized predictive control of P.W.R. nuclear power plant)

  • 천희영;박귀태;이종렬;박영환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.663-668
    • /
    • 1990
  • This paper deals with the application of a Generalized Predictive Control (CPC) to a Pressurized Water Reactor (P.W.R) Nuclear Power Plant. Generalized Predictive Control is a sort of Explicit Self-Tuning Control. Current self-tuning algorithms lack robustness to prior choices of either dead-time (input time delay of a plant) or model order. GPC is shown by simulation studies to be superior to accepted self-tuning techniques such as minimum variance and pole-placement from the viewpoint that it is robust to prior choices of dead-time or model order. In this paper a GPC controller is designed to control the P.W.R. nuclear power rlant with varying dead-time and through the designing procedure the designer is free from the constraint of knowing the exact dead-time. The controller is constructed based on the 2nd order linear model approximated in the vicinity of operating point. To ensure that this low-order model describes the complex real dynamics well enough for control purposes, model parameters are updated on-line with a Recursive Least Squares algorithm. Simulation results are successful and show the possibilities of the GPC control application to actual plants with varying or unknown dead-time.

  • PDF

단상 계통연계 인버터를 위한 새로운 고조파 보상법 (A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters)

  • 칸 아마드 레이안;아쉬라프 모하마드 노만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

Intelligent Phase Plane Switching Control of Pneumatic Artificial Muscle Manipulators with Magneto-Rheological Brake

  • Thanh, Tu Diep Cong;Ahn, Kyoung-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1983-1989
    • /
    • 2005
  • Industrial robots are powerful, extremely accurate multi-jointed systems, but they are heavy and highly rigid because of their mechanical structure and motorization. Therefore, sharing the robot working space with its environment is problematic. A novel pneumatic artificial muscle actuator (PAM actuator) has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. Its main advantages are high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks. The PAM is undoubtedly the most promising artificial muscle for the actuation of new types of industrial robots such as Rubber Actuator and PAM manipulators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In addition, the nonlinearities in the PAM manipulator still limit the controllability. Therefore, it is not easy to realize motion with high accuracy and high speed and with respect to various external inertia loads in order to realize a human-friendly therapy robot To overcome these problems a novel controller, which harmonizes a phase plane switching control method with conventional PID controller and the adaptabilities of neural network, is newly proposed. In order to realize satisfactory control performance a variable damper - Magneto-Rheological Brake (MRB) is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control using neural network brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control using neural network and without regard for the changes of external inertia loads.

  • PDF

Robust Active LED Driver with High Power Factor and Low Total Harmonic Distortion Compatible with a Rapid-Start Ballast

  • Park, Chang-Byung;Choi, Bo-Hwan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.226-236
    • /
    • 2014
  • A new active LED driver with high power factor (PF) and low total harmonic distortion (THD) compatible with a rapid-start ballast is proposed. An LC input filter is attached to the ballast to increase PF and reduce THD. A boost converter is then installed to regulate the LED current, where an unstable operating region has been newly identified. The unstable region is successfully stabilized by feedback control with two zeroes. The extremely high overall system of the 10th order is completely analyzed by the newly introduced phasor transformed circuits in static and dynamic analyses. Although a small DC capacitor is utilized, the flicker percentage of the LED is drastically mitigated to 1% by the fast controller. The proposed LED driver that employs a simple controller with a start-up circuit is verified by extensive experiments whose results are in good agreement with the design.