• 제목/요약/키워드: Low on- resistance

검색결과 3,499건 처리시간 0.031초

퍼지이론을 적용한 기존 중저층 철근콘크리트 건축물의 내진성능평가기법 연구 (Study of Seismic Resistance Performance Evaluation Method for Existing Mid-Low Story RC Structure Buildings by Applying Fuzzy Theory)

  • 김동희;김현수
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.53-62
    • /
    • 2017
  • This study aims to establish a seismic resistance performance evaluation method that makes sure to secure the seismic resistance performance of the existing mid-low story reinforced concrete structures. This study focuses on the development of the seismic resistance performance evaluation method for the overall seismic resistance performance evaluation on the buildings by applying fuzzy theory. This seismic resistance performance evaluation method considers the mutual relations among the type of force, the type of member, the type of story, and the states of deterioration of the buildings. The total seismic resistance performance index from this method was calculated by the intensity weight of each evaluation item, fuzzy measure, fuzzy integration. Moreover, the evaluation methodology was established in this study to identify the performance level of the Immediate Occupancy, Life Safe, Collapse Prevention by applying the fuzzy theory.

MOSFET을 이용한 전동기 구동을 위한 저가격형 전류검출법 (A Low-Cost Current-Sensing Scheme for MOSFET Motor Drives)

  • 장성동;정재호;박종규;이균정;신휘범
    • 전력전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.40-47
    • /
    • 2003
  • A low-cost current-sensing scheme for the motor drives with MOSFET is described. Many motor drives usually employ the common current sensors to measure current for the purpose of control or protection. These current sensors, however, significantly burden the power circuit with the size and cost. The proposed current-sensing scheme utilizes information concerning MOSFET's On-voltage and On-resistance. An analogue circuit detecting On-voltage can overcome the above disadvantages because the circuit is small and is made at a low cost, and the fuzzy inference for On-resistance is also simply designed based on MOSFET's characteristics. The validity of this scheme will be experimentally verified by adopting the current control of a battery car.

속도와 2차 저항의 동시 추정이 가능한 유도전동기의 극 저속 영역 센서리스 속도제어 (Sensorless Control of Induction Motors with Simultaneous Estimation of Speed and Rotor Resistance in the Very Low Speed Region)

  • 정석권;이진국;유삼상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.552-561
    • /
    • 2004
  • This paper is concerned with a new speed sensorless induction motor scheme which can be successfully applied to at any speed including even zero speed. The proposed method is robust against rotor resistance variations. In addition, simultaneous on-line estimations of speed and rotor resistance are realized based on a feedforward type torque control approach. The rotor flux with a low frequency sinusoidal waveform has been utilized to help the simultaneous estimation for both speed and rotor resistance. The control scheme has no current minor loop to determine voltage references. Since the proposed estimation does not depend on any derivative terms of currents and stator voltages, it offers a good performance at extremely low speed region for sensorless induction motor. Furthermore, the proposed control is simply using motor parameters and stator currents without determining any PI gains for current feedback and any signal injection for the rotor resistance estimation. Finally, both simulation and experimental results are given to show the effectiveness of this method.

Low-cost Contact formation of High-Efficiency Crystalline Silicon Solar Cells by Plating

  • 김동섭;이은주;김정;이수홍
    • 신재생에너지
    • /
    • 제1권1호
    • /
    • pp.37-43
    • /
    • 2005
  • High-efficiency silicon solar cells have potential applications on mobile electronics and electrical vehicles. The fabrication processes of the high efficiency cells necessitate com placated fabrication precesses and expensive materials. Ti/Pd/Ag metal contact has been used only for limited area In spite of good stability and low contact resistance because of Its expensive material cost and precesses. Screen printed contact formed by Ag paste causes a low fill factor and a high shading loss of commercial solar cells because of high contact resistance and a low aspect ratio. Low cost Ni/Cu metal contact has been formed by using a low cost electroless and electroplating. Nickel silicide formation at the interface enhances stability and reduces the contact resistance resulting In an energy conversion efficiency of $20.2\%\;on\;0.50{\Omega}cm$ FZ wafer. Tapered contact structure has been applied to large area solar cells with $6.7\times6.7cm^2$ in order to reduce power losses by the front contact The tapered front metal contact Is easily formed by the electroplating technique producing $45cm^2$ solar cells with an efficiency of $21.4\%$ on $21.4\%\;on\;2{\Omega}cm$ FZ wafer.

  • PDF

Does minimally invasive canal preparation provide higher fracture resistance of endodontically treated teeth? A systematic review of in vitro studies

  • Sila Nur Usta;Emmanuel Joao Nogueira Leal Silva;Seda Falakaloglu;Mustafa Gundogar
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • This systematic review aimed to investigate whether minimally invasive root canal preparation ensures higher fracture resistance compared to conventional root canal preparation in endodontically treated teeth (ETT). A comprehensive search strategy was conducted on the "PubMed, Web of Science, and Scopus" databases, alongside reference and hand searches, with language restrictions applied. Two independent reviews selected pertinent laboratory studies that explored the effect of minimally invasive root canal preparation on fracture resistance, in comparison to larger preparation counterparts. The quality of the studies was assessed, and the risk of bias was categorized as low, moderate, or high. The electronic search yielded a total of 1,767 articles. After applying eligibility criteria, 8 studies were included. Given the low methodological quality of these studies and the large variability of fracture resistance values, the impact of reduced apical size and/or taper on the fracture resistance of the ETT can be considered uncertain. This systematic review could not reveal sufficient evidence regarding the effect of minimally invasive preparation on increasing fracture resistance of ETT, primarily due to the inherent limitations of the studies and the moderate risk of bias.

AISI316L 강에 저온 플라즈마침탄 및 DLC 복합 코팅처리 시 처리온도에 따른 표면특성평가 (Influence of Treatment Temperature on Surface Characteristics during Low Temperature Plasma Carburizing and DLC duplex treatment of AISI316L Stainless Steel)

  • 이인섭
    • 한국해양공학회지
    • /
    • 제25권6호
    • /
    • pp.60-65
    • /
    • 2011
  • A low temperature plasma carburizing process was performed on AISI 316L austenitic stainless steel to achieve an enhancement of the surface hardness without degradation of its corrosion resistance. Attempts were made to investigate the influence of the processing temperatures on the surface hardened layer during low temperature plasma carburizing in order to obtain the optimum processing conditions. The expanded austenite (${\gamma}_c$) phase, which contains a high saturation of carbon (S phase), was formed on all of the treated surfaces. Precipitates of chromium carbides were detected in the hardened layer (C-enriched layer) only for the specimen treated at $550^{\circ}C$. The hardened layer thickness of ${\gamma}_c$ increased up to about $65{\mu}m$ with increasing treatment temperature. The surface hardness reached about 900 $HK_{0.05}$, which is about 4 times higher than that of the untreated sample (250 $HK_{0.05}$). A minor loss in corrosion resistance was observed for the specimens treated at temperatures of $300^{\circ}C{\sim}450^{\circ}C$ compared with untreated austenitic stainless steel. In particular, the precipitation of chromium carbides at $550^{\circ}C$ led to a significant decrease in the corrosion resistance. A diamond-like carbon (DLC) film coating was applied to improve the wear and friction properties of the S phase layer. The DLC film showed a low and stable friction coefficient value of about 0.1 compared with that of the carburized surface (about 0.45). The hardness and corrosion resistance of the S phase layer were further improved by the application of such a DLC film.

저발열시멘트 모르터의 호학저항성에 대한 실험적 연구 (An Experimental Study on the Resistance of Low-Heat Cement Mortar in Chemical Attack)

  • 문한영;신화철;김성수;강석화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.183-186
    • /
    • 1998
  • This paper deals with 28, 56, 91 days age compressive strength and ratio of weight when OPC and Low-Heat cement mortar immersed in chemical solution. As a result of experiment, the resistance of Low-Heat Cement motar in chemical attack is more effective than that of OPC, because of lower $C_3$A content and Pozzolanic reactions. Especially in long term age compressive strength, Low-Heat cement mortar shows higher strength in all kind of chemical solution compared with compressive strength of OPC motar.

  • PDF

저발열시멘트 콘크리트의 기초적 성질에 대한 연구 (A Study on the Properties of Low-Heat Cement Concrete)

  • 문한영;김성수;신화철;강석화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.57-60
    • /
    • 1997
  • The properties of Low-heat cement are especially in lower heat of hydration than that of other types of cement. In other respect, Low-heat concrete is more advantageous than OPC concrete in chemical resistance, long term age compressive strength, slump loss and resistance to seawater. This paper deals with 28 days age compressive strength and slump loss by elapsed time of mortar and concrete that made with Low-heat cement and 3 types of other cement.

  • PDF

케이크 여과에 영향을 미치는 요인에 관한 연구 (A Study on the Factors Affecting Cake Filtration)

  • 장재선
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.7-11
    • /
    • 1995
  • This study was carried out to investigate the change of average specific resistance according to filtration pressure, suspension concentration and filters for study phenomena occurring in cake filtration. As the results of this study, the following conclusions were obtained. It was estimated that the average specific resistance of filtration Was decreased in proportion to decreased of filtration pressure. But in very pressure, average specific resistance was increased. The average specific resistance value on filter medium by various pressure was showed as same trends under constant suspension concentration. This phenomenon was though that a carrain amount of fine particles in the cake was found to migrate throught the cake in the case of very thin at very low pressure. In relation to the change of suspension concentration, average specific resistance value become low according to decreased in supension concentration.

  • PDF

Breaker Point 型 점火裝置 性能 을 極大化하기 위한 Pre - Resistance 효果 에 對한 硏究 (A Study of the Pre-Resistance Effects on the Optimization For Performance of the Ignition System with the Breaker Point Type)

  • 손병진;신영철
    • 대한기계학회논문집
    • /
    • 제6권2호
    • /
    • pp.133-139
    • /
    • 1982
  • One of factors that affect combustion in the cylinder of the engine is to keep a greater energy in the ignition system to minimize pollutant emissions and to increase its performance of the low temperature. This paper reviews theoretically the state and input variables of the ignition system from the state transition equation. Effects on characteristics of the system such as primary current, secondary available voltage and spark duration by reducing the pre-resistance from 3.5 to 0 ohm in 12V system is experimentally investigated when the ignition coil has a primary resistance of 1.5 ohms ad the dwell angle of the breaker point is 43.2 degrees (0.75 radian). Advantages and limitations for using the low resistance of the primary circuit are also presented to optimize the performance of the ignition system with the breaker point.