• Title/Summary/Keyword: Low magnetic field

Search Result 798, Processing Time 0.024 seconds

SPACE PHYSICS PACKAGE ON KAISTSAT-4 (과학위성 1호의 우주 플라즈마 관측 시스템)

  • HWANG JUNG-A;LEE JAE-JIN;LEE DAE-HEE;LEE JIN-GUN;KIM HEE-JUN;PARK JAE-HEUNG;MIN KYOUNG WOOK;SHIN YOUNG-HOON
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.45-52
    • /
    • 2000
  • Four plasma instruments are currently under development for KAISTSAT-4 (K-4) which is scheduled for launch in 2002. They are the Solid-State Telescope, Electro-Static Analyzer, Langmuir Probe, and the Scientific Magnetometer, that will respectively allow in-situ detection of high energy and low energy components of auroral particles, ionospheric thermal electrons, and magnetic field disturbances. These instruments, together with the Far-ultraviolet IMaging Spectrograph, will provide micro-scale physics of Earth's polar ionosphere with detailed spectral information that has not been previously achieved with other space missions. In this paper, we review the concept of the four space plasma instruments as well as the anticipated results from the instruments.

  • PDF

실험 대상에 따른 다양한 Birdcage Resonator의 개발

  • 이정우;윤성익;최보영;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.47-47
    • /
    • 2003
  • Abstract: RF Birdcage Resonator는 높은 자장 균질성과 신호 대 잡음비의 특성이 좋음으로 인해 MRI와 MRS 연구에 보편적으로 사용되고 있다. 본 연구는 인체를 비롯한 동물실험을 위한 다양한 실험대상에 따라 코일의 크기를 예측하여 Birdcage Resonator를 개발하였다. Unloaded와 Loaded 상태에서의 전기적인 성향을 Lumped Element Circuit Theory를 따라 일반적인 분석을 하였을 뿐 아니라 실제적인 실험을 통한 분석도 하였다. Introduction: Birdcage Resonator 는 자장 균일성이 뛰어나고 신호대잡음비가 좋아 Magnetic Resonance Imaging과 Spectroscopy에 유용하게 사용되어지고 있다. 이 연구에서는 실험대상에 따른 여러 가지의 Birdcage Resonator를 개발하기 위해 Lumped Element Circuit Theory를 사용한 일반적인 이론적 방법론을 이용하여 코일을 분석하였을 뿐 아니라 실제 제작한 후 실험을 통한 실질적인 영상분석도 병행하여 진행하였다. Method: 실질적인 개발에 앞서 Lumped Element Circuit Theory를 통해 이론적인 분석으로부터 나온 여러 parameter들을 정리하였다. 제작 후 실험적인 분석은 Network Analyzer (HP 4195A, 미국)를 통한 1차적인 분석을 한 후 최종적으로 3T MRI 장비 (메디너스, 한국)에서 수행하였다. 제작된 Birdcage Resonator의 종류는 기본적으로 Low-Pass Filter를 적용한 12-column 구조이다. 각각의 직경과 element의 길이는 다음과 같다. 1) 직경 13cm, element의 길이 22cm, 2) 직경 15cm, element의 길이 22cm, 3) 직경 17 cm, element의 길이 25cm. Result and Discussion: 여러 parameter들을 이론적으로 계산하여 실제 Birdcage Resonator를 제작하여 실험적인 분석을 한 결과 많은 차이가 있음을 알 수 있었다. 그 이유는 이론적인 계산에서는 생각되지 않았던 요인들이 실제 제작에 있어서는 많은 영향을 미쳤기 때문인 것이다. Network Analyzer를 통한 1차적인 분석 후에도 실제의 Magnet Field내에서 또 다시 차이가 나는 것 또한 같은 이유에서이다. 그러므로 Birdcage Resonator 제작에 있어서 이러한 여러 요인들을 충분히 고려하여야 할 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002) 지원아래 수행되었다.

  • PDF

A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare (스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구)

  • Lee, Seong-Su;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Byoung-Hun;Kim, Kyeoung-Seop;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.917-927
    • /
    • 2018
  • High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.

Idiopathic Hypertrophic Spinal Pachymeningitis with an Osteolytic Lesion

  • Jee, Tae Keun;Lee, Sun-Ho;Kim, Eun-Sang;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.162-165
    • /
    • 2014
  • Idiopathic hypertrophic spinal pachymeningitis (IHSP) is a chronic, progressive, inflammatory disorder characterized by marked fibrosis of the spinal dura mater with unknown etiology. According to the location of the lesion, it might induce neurologic deficits by compression of spinal cord and nerve root. A 58-year old female with a 3-year history of progressive weakness in both lower extremities was referred to our institute. Spinal computed tomography (CT) scan showed an osteolytic lesion involving base of the C6 spinous process with adjacent epidural mass. Magnetic resonance imaging (MRI) revealed an epidural mass involving dorsal aspect of cervical spinal canal from C5 to C7 level, with low signal intensity on T1 and T2 weighted images and non-enhancement on T1 weighted-enhanced images. We decided to undertake surgical exploration. At the operation field, there was yellow colored, thickened fibrous tissue over the dura mater. The lesion was removed totally, and decompression of spinal cord was achieved. Symptoms improved partially after the operation. Histopathologically, fibrotic pachymeninges with scanty inflammatory cells was revealed, which was compatible with diagnosis of idiopathic hypertrophic pachymeningitis. Six months after operation, motor power grade of both lower extremities was normal on physical examination. However, the patient still complained of mild weakness in the right lower extremity. Although the nature of IHSP is generally indolent, decompressive surgery should be considered for the patient with definite or progressive neurologic symptoms in order to prevent further deterioration. In addition, IHSP can present as an osteolytic lesion. Differential diagnosis with neoplastic disease, including giant cell tumor, is important.

Compensation of Magnetometer in the Navigation System for Unmanned Helicopter using an Electric Motor (전기모터를 사용한 소형 무인헬리콥터에 활용될 항법장치용 자장계의 보상)

  • Lee, Gilho;Jo, Sungbeom;Kim, Jungsung;Choi, Keeyoung;Kee, Changdon;Song, Yongkyu;Koo, Wheonjoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.11
    • /
    • pp.997-1003
    • /
    • 2012
  • GNSS and ARS are the most common sensors in low-end UAVs. However, these sensors are vulnerable to built-in errors and cannot measure the body heading independently. The GNSS/INS cannot fully compensate the IMU errors in initial alignment process and rectilinear flights. For an unmanned helicopter, a magnetometer can be more useful than any other sensors to obtain heading information. However, the electric motor which drives small helicopter UAV keeps the magnetometer from reading the pure magnetotelluric vector. This paper shows the effects of electric motor on the magnetometer readings, and presents a method to compensate the effects. The results are verified with flight test data. The simulation and experimental results in this paper proves that aiding GNSS/INS with magnetometer increases observability and improves accuracy.

Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device (홀소자를 이용한 손목착용 맥진기의 혈압추정 알고리즘)

  • Ahn, Myung-Cheon;Cho, Jong-Gu;Son, Il-Ho;Lee, Sang-Suk;Kim, Kuen-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.106-113
    • /
    • 2010
  • In order to get the precise blood pressure and pulse number in the cuffless status, the wrist wearable pulsimeter with a portable and small size apparatus using by Hall device is developed. The regression analysis of the pulse wave measured by the testing product of pulsimeter is conducted two equations of the blood pressure algorithm. The estimated values of blood pressure obtained by the cuffless pulsimeter during 5 s are compared with the practical values measured by electronic or mercury liquid blood pressure meters. The standard deviation of the estimated value and the practical value for the high blood pressure and the low blood pressure were 12.1 and 5.9, respectively, which have the neighborhood values of BP International Standard. The detail analysis of a pulse wave measured by cuffless wrist wearable detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus like as the wrist wearable pulsimeter.

Clinical Applications of 3T MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chu, Myung-Ja;Jeun, Sin-Soo;Kang, Sei-Kwon;Chung, Sung-Taek;Park, Chi-Bong;Oh, Chang-Hyun;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.345-351
    • /
    • 2002
  • The purpose of this study was to assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating brain tumor malignancy at 3T high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxe1 technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67${\pm}$018 and 1.16${\pm}$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (p=0.005), but Cho/Cr ratio of all tumor tissue was significantly higher (p=0.001). Cho/Cr ratio of high-grade gliomas was significantly higher than that of low-grade gliomas (P=0.001). Except 4 menigiomas, lactate signal was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. Our results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

A Study on the Electronic Properties and Redox Reaction of Palladium(Ⅱ) and Platinum(Ⅱ) Alkylsulfoxide Complexes in Aprotic Solvent [Ⅱ] (비양성자성 용매속에서 Pd(Ⅱ)와 Pt(Ⅱ) 알킬슬폭사이드 착물에 대한 전자적 성질과 산화 · 환원반응에 관한 연구 [Ⅱ])

  • Choe, Chil Nam;Son, Hyo Youl;Kim, Se Bong
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.10
    • /
    • pp.649-655
    • /
    • 1996
  • The chemical behaviour of Pt(Ⅱ) and Pd(Ⅱ) complexes with the organic ligand tetramethylenesulfoxide(TMSO) has been investigated by UV/vis-spectrophotometric, magnetic, and electrochemical methods. Two energy absorption bands are observed in the spectra of these complexes. The crystal field splitting energy, spin pairing energy, and bond strength were obtained from the spectra of the complexes. The electronic properties of the complexes are found to be delocalized, and low-spin state. The correlation between ligand and metals were strong bonding strength. These complexes are diamagnetics. The redox reaction processes of the complexes were investigated by cyclic voltammetry in an aprotic solvent. The redox processes of complexes turned out to be respect to one-electrton one step. These complexes were considerably diffusion and reaction controlled.

  • PDF

Non-monotonic Size Dependence of Electron Mobility in Indium Oxide Nanocrystals Thin Film Transistor

  • Pham, Hien Thu;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2505-2511
    • /
    • 2014
  • Indium oxide nanocrystals ($In_2O_3$ NCs) with sizes of 5.5 nm-10 nm were synthesized by hot injection of the mixture precursors, indium acetate and oleic acid, into alcohol solution (1-octadecanol and 1-octadecence mixture). Field emission transmission electron microscopy (FE-TEM), High resolution X-Ray diffraction (X-ray), Nuclear magnetic resonance (NMR), and Fourier transform infrared spectroscopy (FT-IR) were employed to investigate the size, surface molecular structure, and crystallinity of the synthesized $In_2O_3$ NCs. When covered by oleic acid as a capping group, the $In_2O_3$ NCs had a high crystallinity with a cubic structure, demonstrating a narrow size distribution. A high mobility of $2.51cm^2/V{\cdot}s$ and an on/off current ratio of about $1.0{\times}10^3$ were observed with an $In_2O_3$ NCs thin film transistor (TFT) device, where the channel layer of $In_2O_3$ NCs thin films were formed by a solution process of spin coating, cured at a relatively low temperature, $350^{\circ}C$. A size-dependent, non-monotonic trend on electron mobility was distinctly observed: the electron mobility increased from $0.43cm^2/V{\cdot}s$ for NCs with a 5.5 nm diameter to $2.51cm^2/V{\cdot}s$ for NCs with a diameter of 7.1 nm, and then decreased for NCs larger than 7.1 nm. This phenomenon is clearly explained by the combination of a smaller number of hops, a decrease in charging energy, and a decrease in electronic coupling with the increasing NC size, where the crossover diameter is estimated to be 7.1 nm. The decrease in electronic coupling proved to be the decisive factor giving rise to the decrease in the mobility associated with increasing size in the larger NCs above the crossover diameter.

PAGAN I: MULTI-FREQUENCY POLARIMETRY OF AGN JETS WITH KVN

  • KIM, JAE-YOUNG;TRIPPE, SASCHA;SOHN, BONG WON;OH, JUNGHWAN;PARK, JONG-HO;LEE, SANG-SUNG;LEE, TAESEOK;KIM, DAEWON
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.285-298
    • /
    • 2015
  • Active Galactic Nuclei (AGN) with bright radio jets offer the opportunity to study the structure of and physical conditions in relativistic outflows. For such studies, multi-frequency polarimetric very long baseline interferometric (VLBI) observations are important as they directly probe particle densities, magnetic field geometries, and several other parameters. We present results from first-epoch data obtained by the Korean VLBI Network (KVN) within the frame of the Plasma Physics of Active Galactic Nuclei (PAGaN) project. We observed seven radio-bright nearby AGN at frequencies of 22, 43, 86, and 129 GHz in dual polarization mode. Our observations constrain apparent brightness temperatures of jet components and radio cores in our sample to > 108.01 K and > 109.86 K, respectively. Degrees of linear polarization mL are relatively low overall: less than 10%. This indicates suppression of polarization by strong turbulence in the jets. We found an exceptionally high degree of polarization in a jet component of BL Lac at 43 GHz, with mL ~ 40%. Assuming a transverse shock front propagating downstream along the jet, the shock front being almost parallel to the line of sight can explain the high degree of polarization.