• Title/Summary/Keyword: Low magnetic field

Search Result 798, Processing Time 0.026 seconds

Magnetic Characteristics of CoNbZr amorphous Films with Pd addition

  • Song, J.S.;Wee, S.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.90-95
    • /
    • 2003
  • The present paper is to investigate the phase stability and soft magnetic properties of amorphous CoNbZr films when Pd is added as a substitution for CoNbZr alloys. The films were prepared by a RF magnetron sputtering method. The CoNbZrPd films deposited on Si wafers exhibited amorphous structures being independent upon the amount of Pd added in the films. On the addition of 4.34% Pd, the excellent soft magnetic characteristics of the films were observed with a coercive force of 0.54 Oe and an anisotropy field of 11 Oe, whereas a coercive force of 1 Oe and an anisotropy field of 3.5 Oe were shown in the film without the addition of Pd. The increased anisotropy field and low coercive force of the films may be attributed to the occupancy of Pd in the preferred sites parallel to the external magnetic field applied on the deposition process. A permeability of about 1100 was kept constant in the operation frequency ranging up to 100 MHz, which can be explained by the Landau-Lifshitz formula.

  • PDF

Soft Magnetic Properties of CoNbZr amorphous Films with Pd addition

  • Song, J.S,;Wee, S.B,
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.54-58
    • /
    • 2002
  • The present paper is to investigate the phase stability and soft magnetic properties of amorphous CoNbZr films when Pd is added as a substitution for CoNbZr alloys. The films were prepared by a RF magnetron sputtering method. The CoNbZrPd films deposited on Si wafers exhibited amorphous structures being independent upon the amount of Pd added in the films. On the addition of 4.34% Pd, the excellent soft magnetic characteristics of the films were observed with a coercive force of 0.54 Oe and an anisotropy field of 11 Oe, whereas a coercive force of 1 Oe and an anisotropy field of 3.5 Oe were shown in the film without the addition of Pd. The increased anisotropy field and low coercive force of the films may be attributed to the occupancy of Pd in the preferred sites parallel to the external magnetic field applied on the deposition process. A permeability of about 1100 was kept constant in the operation frequency ranging up to 100 MHz, which can be explained by the Landau-Lifshitz formula.

  • PDF

Corrosion behavior and mechanism of CLAM and 316L steels in flowing Pb-17Li alloy under magnetic field

  • Xiao, Zunqi;Liu, Jing;Jiang, Zhizhong;Luo, Lin;Huang, Qunying
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.1962-1971
    • /
    • 2022
  • The liquid lead-lithium (Pb-17Li) blanket has many applications in fusion reactors due to its good tritium breeding performance, high heat transfer efficiency and safety. The compatibility of liquid Pb-17Li alloy with the structural material of blanket under magnetic field is one of the concerns. In this study, corrosion experiments China low activation martensitic (CLAM) steel and 316L steel were carried out in a forced convection Pb-17Li loop under 1.0 T magnetic field at 480 ℃ for 1000 h. The corrosion results on 316L steel showed the characteristic with a superficial porous layer resulted from selective leaching of high-soluble alloy elements and subsequent phase transformation from austenitic matrix to ferritic phase. Then the porous layers were eroded by high-velocity jet fluid. The main corrosion mechanism of CLAM steel was selective dissolution-base corrosion attack on the microstructure boundary regions and exclusively on high residual stress areas. CLAM steel performed a better corrosion resistance than that of 316L steel. The high Ni dissolution rate and the erosion of corroded layers are the main causes for the severe corrosion of 316L steel.

A Study on the Design of Valve Mode MR Damper using Permanent Magnet (영구자석을 이용한 밸브모드 MR 감쇠기 설계에 관한 연구)

  • Kim, Jung-Hoon;Oh, Jun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.69-76
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectiories.

  • PDF

Analysis on the Magnetic Field Distribution of Low-Tc Superconducting Power Supply Using Finite Element Method (유한요소법을 이용한 저온초전도전원장치의 자기장분포 해석)

  • Bae, Duck-Kweon;Yoon, Yong-Soo;Kim, Ho-Min;Ahn, Min-Cheol;Kim, Yeong-Sik;Han, Tae-Su;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.739-741
    • /
    • 2001
  • Magnetic field distribution of rotating flux type Low-Tc superconducting (LTS) power supply with respect to the applied current on exciters is investigated in detail by using Finite Element Method (FEM). LTS power supply consists of two exciters, a rotor, a stator and superconductor foil attached to the inner surface of the stator and LTS load. The current pumping of LTS power supply is induced by partial-quenching and recovery of superconductor foil. For this reason, magnetic flux density on superconductor foil must be sufficiently greater than the its critical magnetic density. In this analysis, the normal spot on superconductor foil appears more than 10A of excitation current. The results of this analysis are calculated and compared with the experimental results.

  • PDF

Superconducting high gradient magnetic separation for magnetic substance at sludge powder of hot rolled coolant

  • Kwon, Jun-Mo;Ha, Dong-Woo;Kim, Tae-Hyung;Cho, Mun-Dak;Choi, Woo-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.353-353
    • /
    • 2009
  • It is an important task to construct a recycling society with a low damage on the environment in our century. Magnetic separation is expected to be applied for the industrial waste treatment as an important supporting technology. In the magnetic separation of dry condition, the cohesive force between particles is strong compared with that in the wet condition's magnetic separation. The use of high magnetic field by the superconducting magnet enhances the powder's magnetic substance capture ability of the magnetic separation. In this study, the POSCO's coolant sludge of hot rolled steel was used for the superconducting magnetic separation of dry condition. Cryo-cooled NB-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF

EM Algorithm-based Segmentation of Magnetic Resonance Image Corrupted by Bias Field (바이어스필드에 의해 왜곡된 MRI 영상자료분할을 위한 EM 알고리즘 기반 접근법)

  • 김승구
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.305-319
    • /
    • 2003
  • This paper provides a non-Bayesian method based on the expanded EM algorithm for segmenting the magnetic resonance images degraded by bias field. For the images with the intensity as a pixel value, many segmentation methods often fail to segment it because of the bias field(with low frequency) as well as noise(with high frequency). Our contextual approach is appropriately designed by using normal mixture model incorporated with Markov random field for noise-corrective segmentation and by using the penalized likelihood to estimate bias field for efficient bias filed-correction.

Transport Loss Characteristics of a Bi-2223 Tape in External AC Magnetic Fields (외부 교류지장에 대한 Bi-2223테이프의 통전손실 특성)

  • Ryu, Kyung-Woo;Kim, Chang-Wan;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.290-295
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic fields was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. A serous increase of the transport loss due to external AC magnetic field is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the external fields.

  • PDF

A study on Dynamic Characteristics of an Eddy Current Damping (와전류감쇠기의 동특성에 관한 연구)

  • Park, Jungsam;Bae, Jaesung;Hwang, Jaihyuk;Kang, Kukjeong
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.3
    • /
    • pp.24-28
    • /
    • 2008
  • Eddy current are induced when a nonmagnetic, conductive material is moving as the result of being subjected to the magnetic field, or if it is placed in a time-varying magnetic field. These currents circulate in the conductive material and are dissipated, causing a repulsive force between the magnet and conductor. Using this concept, eddy current damping can be used as a form of viscous damping. This paper investigated analytically and experimentally the characteristics of an eddy current damping when a permanent magnet is placed in a conductive tube. The theoretical model of the eddy current damping is developed from electromagnetics and is verified from Maxwell program and experiments. From these comparisons, although predictability is not accurate at high excitation frequencies, the present model can be used to predict damping force at low excitation frequencies. In order to improve the prediction of the characteristics of an eddy current damping, the induced magnetic flux densities have to be considered in following researches.

  • PDF

Effect of Alternating Magnetic Field on Ion Activation in Low Temperature Polycrystalline Silicon Technology

  • Hwang, Jin Ha;Lim, Tae Hyung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2004
  • Statistical design of experiments was successfully employed to investigate the effect of alternating magnetic field on activation of polycrystalline Si (p-Si) doped as n-type using $\textrm{PH}_3$, by full factorial design of three factors with two levels. In this design, the input variables are graphite size, alternating current, and activation time. The output parameter, sheet resistance, is analyzed in terms of the primary effects and multi-factor interactions. Notably, the three-factor interaction is calculated to be a dominant interaction. The interaction between graphite size and activation time and the main effect of current are important effects compared to the other variables and relevant interactions. Alternating magnetic flux activation is proved a significantly beneficial processing technique.

  • PDF