• Title/Summary/Keyword: Low magnetic field

Search Result 792, Processing Time 0.024 seconds

A study on the characteristics of axially magnetized capacitively coupled radio frequency plasma (축 방향 자장이 인가된 용량 결합형 라디오 주파수 플라즈마의 특성 연구)

  • Lee, Ho-Jun;Yi, Dong-Yung;Tae, Heung-Sik;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1066-1068
    • /
    • 1999
  • Magnetic field is commonly used in low temperature processing plasmas in order to obtain high density. E $\times$ B magnetron or surface multipole configuration were most popular. However, the properties of capacitively coupled rf plasma confined by axially applied static magnetic fields have rarely been studied. In this paper, the effects of magnetic field on the characteristics of 13.56MHz/40KHz argon plasma will be reported. Ion saturation current, electron temperature and plasma potential were measured by Langmuir probe and omissive probe. At low pressure region ($\sim$10mTorr), ion current was increased by a factor of 3 - 4 due to reduction of diffusion loss of charged particles to the wall. It was observed that magnetic field induces large time variation of the plasma potential. The experimental result was compared with particle-in-cell simulation. It was also observed that electron temperature tend to decrease with increasing magnetic induction level for 40KHz discharge.

  • PDF

Biological Effects of Static Magnetic Fields and ELF-Electromagnetic Field on Microcirculation in Animals

  • Ohkubo, Chiyoji;Okano, Hidyuki;Xu, Shenzhi;Gmitrov, Jraj
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 1999.07a
    • /
    • pp.117-129
    • /
    • 1999
  • Acute effects of locally applied of static magnetic field (SMF) and extremely low frequency electromagnetic field(ELF-EMF) to the cutaneous tissue within a rabbit ear chamber (REC)were evaluated under conscious conditions. Rabbits with the REC were subjected to intravital microscopical investigation by use of microphotoelectric plethysmography(MPPG). There was no dose-response relationship between the extent of vasomotion changes and frequencies(0,20,50, 100Hz)or power levels (1, 5, 10, 25, 50, 100, 200 mT). Under low vascular tone the both fields induce vasodilatation. The effects of SMF (1 mT) on the cutaneous microcirculatory system induced the vasodilatation with enhanced vasomotion under nor-adrenaline-induced high vascular tone as well as the vasoconstriction with reduced vasomotion under acetylcholine-induced low vascular tone. This suggests that the SMF can modulate vascular tone due to the modification of vasomotion biphasically in the cutaneous tissue.

  • PDF

EQUIVALENT CIRCUIT REPRENSENTATION OF MAGNETIC FIELDS BASED ON FINITE ELEMENT MODELLING

  • Y. Kagawa;N. Wakatsuki;Kim, A. ura
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.205-208
    • /
    • 2001
  • A lumped electrical circuit is an approximate representation of the field within a curtain frequency range. The finite element modelling is a synonym of the equivalent circuit. The electric conduction field and electric potential wave field have been modelled by an admittance network and an LC low-pass filter network. Here in the present paper, the equivalent magnetic circuit representation is created for a magnetostatic field by the finite element modelling in two dimension.

  • PDF

Simulations of Ferromagnetic Resonance Spectra Excited in Magnetic Bilayers (이층 자성막에서 여기되는 강자성 공명신호의 모의실험)

  • 김약연;한기평;유성초
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.238-246
    • /
    • 2003
  • We have performed the simulation of ferromagnetic resonance spectra on the exchange coupled bilayer thin films at perpendicular configuration. Variables considered in spectrum calculation were the interfacial exchange constants per unit area, the layer thickness, and the surface anisotropy constants. In case of antiferromagnetic coupling, variation of exchange constant gave a great effect to the absorption spectra of the low and the high magnetization layer. Variation of thickness in low magnetization layer did nt nearly influenced the resonated field of the high magnetization layer. Also, the increase of negative surface anisotropy increased the resonance field of the low and the high magnetization layer.

Positioning sensor system for mobile robots using magnetic markers (마그네틱 마커를 이용하는 이동로봇을 위한 위치인식 센서 시스템)

  • Kim, Eui-Sun;Kim, Won-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.221-229
    • /
    • 2010
  • In recent studies, many methods have been studied for mobile robot using magnetic markers on its pathway. This is not influenced by the weather conditions, and makes possible to develop controller with low level processors and simple algorithms. However, the interval between magnets is restricted by the magnetic field intensity and it is impossible to get road information ahead. This paper suggests a method of widening markers and expressing the road information ahead using magnetic markers, and explains a sensor arrangement considering suggested methods. Also, magnetic field analysis was done to investigate the effects of widening magnetic markers with various environments. A small mobile robot was made to figure out the performance of suggested methods, and driving experiments were performed on the straight and curved road with magnetic markers. The results show that the robot moved the prearranged pathway with 0.5 cm lateral displacements and stopped at a stop line using magnetic information on the road.

Performance and Manufacture of the Apparatus Generating Artificial Magnetic Field of 3-axis Type (3축형 인공자장발생장치의 제작과 성능에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • The objects of this study were to discuss the performance of its using magnetic compass and to do a trial manufacture of the apparatus generating artificial magnetic field of 3-axis type to assess the performance of compass using terrestrial magnetism in the various magnetic field. The results obtained were summarized as follows: The magnetic field of each axis showed the linearly increase in accordance with the increase of electrical current. Average range difference between measured and calculated values was 0.33∼1.93μT and there were no big difference. The magnitude and direction of magnetic field showed some change in the edge of Helmholtz coil, but it appeared to stabilize in the center. In the horizontal magnetic force of 0.30gauss and 0.40gauss, the measured and calculated values of the damping characteristic of magnetic compass showed a good agreement. However, the confidence level was low at the horizontal magnetic force of 0.50gauss.

Analysis and Improvement of Shielding Effect of Electromagnetic Field in Extremely Low Frequency System (극저주파 시스템에서 전자장 차폐효과 해석 및 개선 방안)

  • Kim, Sang-Hon;Choi, Hong-Soon;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.978-979
    • /
    • 2006
  • Recently, Peoples are exposed the ELF(Extremely Low Frequency) magnetic fields in the vicinity of underground transmission lines, and there are the generally accepted opinion that the magnetic fields affect the human body and there are possibility of the disease. Also in relation to this problem, technical solution methods and research are advanced for reducing the magnetic fields. In this paper, to practically understand the magnetic fields underground transmission lines, We analyze the electromagnetic field distribution in the underground transmission lines by means of FEM(Finite Element Methods) and present that improvement of the effective shielding methods by applying cable arrangements and shielding materials, eddy current problem to the underground transmission lines by means of the numerical analysis Tool.

  • PDF

Mini-review on fabrication of nitrogen vacancy center in diamond and its application to NMR

  • Oh, Sangwon
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.3
    • /
    • pp.73-80
    • /
    • 2019
  • Nitrogen-vacancy (NV) is one of the most popular solid-state spin systems for quantum sensing. NV has been used for vector magnetometry with nanometer spatial resolution and sensors for nuclear magnetic resonance (NMR) in samples with small volume, less than 10 pL. Various studies are in progress to make NV a complementary sensor for current NMR technique. Fabricating and improving diamond itself are one of the research topics. This mini-review contains recent develops in diamond fabrication and treatment for higher NV yield. Additionally, we briefly introduce the development status of NV in NMR.

Magnetoelectric Characteristics on Layered Fe78B13Si9/PZT/Fe78B13Si9 Composites for Magnetic Field Sensor (자기센서용 Fe78B13Si9/PZT/Fe78B13Si9 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.181-187
    • /
    • 2015
  • The magnetoelectric characteristics on layered $Fe_{78}B_{13}Si_9/PZT$ and $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9$($t_m=0.017$, 0.034mm) composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range and resonance frequency range. The optimal bias magnetic field $H_{dc}$ of these samples was about 23~63 Oe range. The Me coefficient of $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9(t_m=0.034mm)$ composites reaches a maximum of $186mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, f=50 Hz and a maximum of $1280mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, resonance frequency $f_r=95.5KHz$. The output voltage shows linearity proportional to ac fields $H_{ac}$ and is about U=0~130.6 mV at $H_{ac}=0{\sim}7Oe$, f=50 Hz, U=0~12.4 V at $H_{ac}=0{\sim}10Oe$, $f_r=95.5KHz$(resonance frequency). The optimal frequency(f=50 Hz) of this sample is around the utility ac frequency(f=60 Hz). Therefore, this sample will allow for ac magnetic field sensor at utility frequency and low bias magnetic fields $H_{dc}$.

The design of low-power MR damper using permanent magnet (영구자석을 이용한 저전력형 MR 감쇠기의 설계)

  • Kim, Jung-Hoon;Oh, Jun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.433-439
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption and small size. To design a MR damper that has a large maximum dissipating torque and a low damping coefficient, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectories.

  • PDF