• Title/Summary/Keyword: Low loading sewage

Search Result 21, Processing Time 0.029 seconds

Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall (강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향)

  • Oa, Seongwook;Kim, Geonha;Son, Bongho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.

The Effect of Organic Loading and Seeding Rate to Biodegradibility of Food Waste (음식물쓰레기의 유기물 부하 및 식종율 변화가 생분해도에 미치는 영향)

  • 박남배;정용현;양병수
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.25-31
    • /
    • 1999
  • Energy recovery technology from municipal solid waste has been increasingly established in many countries. Anaerobic treatment of municipal sewage sludge has low digestion efficiency because of low organic loading rate of sewage sludge. The purpose of this study was to evaluate anaerobic biodegradability of food waste which was based on organic loading rate and seeding rate. From the results of anaerbic biodegration, the optimum condition for seeding rate was turn out over 40%, which did not inhibition of methane production.

  • PDF

The Study on denitrification of low organic loading sewage by pre-denitrification process (유기물부하가 낮은 하수의 전달탈질공법에 의한 탈질방안)

  • Lee, Cheol Seung;Seo, Jong Hwan;Kim, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.779-878
    • /
    • 2004
  • This study was conducted to analyze the operating conditions of predenitrification process to improve the treatment efficiency in low organic loading sewage plant in use today, and to investigate the treatment efficiency of pilot plant added night soil as well as the nitrogen removal characteristics of pilot plant added carbon sources. In the operation under the condition of $BOD_{5}$ sludge load 0.03-0.28kg $BOD_{5}$/kg VSS/d and oxic ammoniac nitrogen sludge load 0.02-0.24 $kgNH_{4}^{+}$-N/kg MLVSS/d, nitrification efficiency is higher than 95%. In order to achieve 70% nitrogen removal at the T-N sludge loading 0.06kg T-N/kg VSSㆍd and the SRT 6~11 days, optimum operating factors were revealed to $CODc_{r}$/T-N ratio 9, recycle ratio 2.6, and denitrification volume ratio 0.33. At this time, denitrification capacity was approximately 0.09 kg $NO_{3}^{-}$-N/kg $CODc_{r}$; specific nitrification rate was 3.4mg $NH_{4}^{+}$-N/g MLVSS/hr; and specific denitrification rate was 4.8mg $NO_{3}^{-}$-N/g MLVSS/hr.

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer (오수관 설계유량 산정법이 설계유속에 미치는 영향)

  • Hyun, In-hwan;Won, Seung-hyun;Kim, Hyung-jun;Lee, Che-in
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

The Feasibility of Co-Incineration for Municipal Solid Waste and Sewage Sludge through the Change of Heat Loading and Atmospheric Pollutants Loading (하수슬러지와 생활폐기물 혼합소각시 열부하 변화 및 대기오염물질 부하 변화를 통한 혼합소각 가능성에 관한 연구)

  • Cho, Jae-Beom;Kim, Woo-Gu;Yeon, Kyeong-Ho;Shin, Jung-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.583-589
    • /
    • 2012
  • The various promotion countermeasures such as solidification, carbonization, and the creation of cement materials have been considered to existing treatment methods such as incineration and the creation of composts, since direct landfill was prohibited for encouraging the recycling based on the sludge treatment on land. The Main objective of this study is to investigate the feasibility of co-incineration for MSW (Municipal Solid Waste) and SS (Sewage Sludge) through the change of heat and atmospheric pollutants. In this study, LHV (Low Heating Value) is 100~300 kcal/kg because the MC (Moisture Content) of de-hydrated sewage sludge is approximately 80%. From the results, we knew the feasibility of co-incineration for MSW (80%) and SS (20%). As the co-incineration rate of SS up to 20% became higher, the loading of heat and atmospheric pollutants was not influenced.

The Influence of the Sewage in Jinju City on the Water Pollution of the Nam River (진주시(晉州市) 생활하수(生活下水)가 남강(南江) 수질오염(水質汚染)에 미치는 영향(影響))

  • Ha, Ho-Sung;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.2
    • /
    • pp.90-97
    • /
    • 1983
  • Water pollution status of the sewage in Jinju City was investigated to provide the basic information for the conservation of the Nam River. Physicochemical characteristics of the sewage were examined at five sites of sewage ditches, Jinyang Lake and Nam River. The results are as follows; 1) Average value of analyzed components of the sewage at five sampling sites were pH 7.1, DO 2.3 ppm, BOD 126.2 ppm, COD 123.7 ppm, turbidity 22.3 ppm, $NH_4^+-N 9.30 ppm$, alkalinity 121 ppm, hardness 121 ppm, Cl 44.3 ppm, $SO_4--$ 88.9 ppm, Pb 0.0052 ppm, Zn 0.0079 ppm, Cu 0.0124 ppm, Mn 0.0050 ppm, respectively. 2) Discharged amount of sewage in Jinju City was $38,720 m^3/day$. BOD loading of the Nam River discharged from the sewage ditches was 4.93 ton/day, and her BOD loading discharged from the Jinyang Lake was 6.94 ton/day. 3) Heavy metals content of the sewage were comparatively low, and then it would not influence the water quality of the Nam River. But $NH_4+$ contents were very high at all sewage ditches. Therefore, the sewage would not suitable for the agricultural irrigation water.

  • PDF

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

The Evaluation of Water Quality in Coastal Sea of Incheon Using a Multivariate Analysis (다변량 해석기법을 이용한 인천연안해역의 수질평가)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1017-1025
    • /
    • 2006
  • This study was conducted to evaluate characteristic of water duality in coastal sea of Incheon using a multivariate analysis. The analysis data in coastal sea of Incheon was aquired by the NFRDI data which was surveyed from March 1997 to November 2003. Eleven water quality parameters were determined on each survey The results were summarized as follow : Water quality in Incheon coastal sea could be explained up to 64.62% by three factors which were included in loading of fresh water and nutrients by the land(36.98%), seasonal variation(16.19%), and internal metabolism (11.24%). The results of time series analysis by factor score, in case of factor 1, station 1 influenced by Han river was shown to high factor score and station 3 located by outer sea was shown to low factor score. In case of factor 2, station 1 was appeared to high variation and station 3 was appeared to low variation. The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, station 1 which affected by Han river and station 4 which affected by sewage treatment plant was appeared to considerable water quality characteristics against other station. In yearly cluster analysis, three group was classified and water quality in 2003 years due to high precipitation was different to another year. It could be suggested from these results that it is important to control discharge of fresh water by Han rivet and sewage treatment plant for water quality management of coastal sea of Incheon.