• 제목/요약/키워드: Low flow

검색결과 6,294건 처리시간 0.041초

An Improved Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling

  • Young Min Kwon;Soon Heung Chang
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.552-557
    • /
    • 1997
  • Based on the bubble coalescence adjacent to the heated wall as a flow structure for CHF condition, Chang and Lee developed a mechanistic critical heat flux (CHF) model for subcooled flow boiling. In this paper, improvements of Chang-Lee model are implemented with more solid theoretical bases for subcooled and low-quality flow boiling in tubes. Nedderman-Shearer's equations for the skin friction factor and universal velocity profile models are employed. Slip effect of movable bubbly layer is implemented to improve the predictability of low mass flow. Also, mechanistic subcooled flow boiling model is used to predict the flow quality and void fraction. The performance of the present model is verified using the KAIST CHF database of water in uniformly heated tubes. It is found that the present model can give a satisfactory agreement with experimental data within less than 9% RMS error.

  • PDF

리어가이더 시작각 변화가 횡류홴 성능에 미치는 영향 (Effects of Starting Angles of a Rearguider on the Performance of a Cross-Flow Fan)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1981-1986
    • /
    • 2004
  • A cross-flow fan relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there exists a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, it is difficult to analyze the reciprocal relations of the cross-flow fan because each parameter is independent. Numerical analyses are conducted with different starting angles of the rearguider. Two-dimensional, unsteady governing equations are solved, using FVM, PISO algorithm, sliding grid system and ${\kappa}-{\varepsilon}$ standard turbulence model.

  • PDF

임펠러 직경비 및 리어가이더 형상변화가 횡류홴 성능에 미치는 실험적 연구 (Experimental Study on the Performance of a Cross-Flow Fan with Various Diameter Ratios of Impeller and Rearguider Shapes)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.391-396
    • /
    • 2003
  • A cross-flow fan relatively produces higher dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. The performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, and 15% by the heat exchanger. At the low flow rate, there exist a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. The purpose of this study is to investigate the reciprocal relation among each parameter Experiments are conducted to study the effects of a rearguider and a diameter ratio of impeller on the performance analysis of a cross-flow fan. Comparing with the rearguider of radial type, the Archimedes type shows excellent results for various diameter ratios.

  • PDF

21AFR 희박연료모듈의 저압 및 고압 연소성능시험 (Performance Test of 21AFR Lean Fuel Module at Low and High Operating Conditions)

  • 한영민;고영성;양수석;이대성
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1132-1137
    • /
    • 2002
  • In this paper, the test results of the combustion for 2 IAFR lean fuel models are described. The need for the low emission combustor has been issued from the concern on the increase of green house and the destruction of ozone layer. To evaluate the flow and combustion performance of newly designed 21AFR lean modules, the hydraulic tests in stereolithographic airflows models, the low pressure combustion tests in three injectors model for weak extinction and ignition and the high pressure combustion tests in single sector for NOx, SAE and efficiency are performed. The low pressure tests reveal that the governing parameters in weak extinction and ignition at atmospheric condition are prefilmer length, swirl flow rotation direction, secondary swirl angle and flow split. As a result of combustion test at high pressure, the efficiency and smoke level are satisfied with performance targets, but EINOx of 17.8 is higher than target value of 13.1 The high pressure tests show that the main parameters influenced on NOx are primary swirl angle, swirl flow rotation direction, heatshield exit angle and liner mixing hole location.

Transient energy flow in ship plate and shell structures under low velocity impact

  • Liu, Z.S.;Swaddiwudhipong, S.;Lu, C.;Hua, J.
    • Structural Engineering and Mechanics
    • /
    • 제20권4호
    • /
    • pp.451-463
    • /
    • 2005
  • Structural members commonly employed in marine and off-shore structures are usually fabricated from plates and shells. Collision of this class of structures is usually modeled as plate and shell structures subjected to dynamic impact loading. The understanding of the dynamic response and energy transmission of the structures subjected to low velocity impact is useful for the efficient design of this type of structures. The transmissions of transient energy flow and dynamic transient response of these structures under low velocity impact are presented in the paper. The structural intensity approach is adopted to study the elastic transient dynamic characteristics of the plate structures under low velocity impact. The nine-node degenerated shell elements are adopted to model both the target and impactor in the dynamic impact response analysis. The structural intensity streamline representation is introduced to interpret energy flow paths for transient dynamic response of the structures. Numerical results, including contact force and transient energy flow vectors as well as structural intensity stream lines, demonstrate the efficiency of the present approach and attenuating impact effects on this type of structures.

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

원심형, 사류형, 축류형 펌프단에서 살펴본 이차유동의 수치적 고찰 (Numerical Investigation of Secondary Flow in 3 Pump Stages: Centrifugal Multistage/Mixed-flow Stage/ Axial-flow Stage)

  • 오종식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.359-364
    • /
    • 2005
  • Centrifugal pump shows the strongest secondary flow. Wake is formed near pressure surface close to hub at impeller exit for centrifugal pump impeller. Pressure gradient drives secondary flow in the inducer region, while in the remaining region the following sources drive together: > Pressure gradient > Coriolis force Low-momentum fluid near suction surface hub moves toward pressure surface hub in mixed-flow pump impeller. Tip leakage vortex dominate secondary flow in axial-flow pump impeller. Tip leakage vortex dominate secondary flow in axial-flow in axial-flow pump impeller

  • PDF

유량지속곡선을 이용한 수문특성별 한강수계 총량관리 단위유역의 오염기여도 추정 (Estimation of Pollution Contribution TMDL Unit Watershed in Han-River according to hydrological characteristic using Flow Duration Curve)

  • 김동영;윤춘경;이한필;최재호;황하선
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.497-509
    • /
    • 2019
  • After the Total Maximum Daily Loads(TMDLs) was applied, it became beyond the limit of concentration management. However, it does not adequately reflect the characteristics of various watersheds, and causes problems with local governments because of the standard flow set. Thus, in this study, the Han River system is organized into four groups in estimating the Pollution Contribution by applying the Flow Duration Curve(FDC) created by the daily flow of data from the HSPF. And the method of this study is expected to be valuable as basic data for the TMDLs. As a result, Group I contains the main watersheds with no large hydraulic structures and tributary watersheds. There is no specificity in the FDC and the Pollution Contribution is estimated as rainfall runoff. Group II contains watersheds near the city where the FDC is maintained above a certain level during the Low Flow Conditions and the Pollution Contribution is estimated as the discharge flow of large scale point pollution facilities. Group III contains the main watersheds in which the large hydraulic structures are installed and FDC is curved in the Low Flow Conditions. So the Pollution Contribution is estimated as the water quality of the large hydraulic structures. Group IV contains the upstream in mainstream watersheds in which the large hydraulic structures are installed and the FDC is disabled before the Low Flow Conditions. As the flow is concentrated in the High Flow Conditions, the non-point pollution sources are estimated as the Pollution Contribution.

복단면인 직선수로 내 사행 저수로의 형태에 따른 흐름특성 연구 (A Study on Flow Characteristics according to Meandering Low Flow Channel Shape in the Compound Cross Section Typed Straight Channel)

  • 김성환;최계운
    • 한국습지학회지
    • /
    • 제19권4호
    • /
    • pp.484-490
    • /
    • 2017
  • 복단면 형태를 이루는 직선하도 내 사행하는 저수로의 형태에 따른 흐름 특성을 파악하기 위해, 국내 대표적인 하도 형태를 상정해 실내 수리모형을 실시해서 3차원 수치모의의 유효성을 확인하고, 이를 바탕으로 다른 유형의 하도 형태에 대해서도 수치모의로 검토를 실시하였다. 본 연구결과, 수리모형 실험에서 관측한 수심별 유속값을 이용하여 수치모형의 검정을 수행한 결과, 수치모의 결과와 충분히 일치하는 것으로 확인하였다. 이를 토대로, 추가적인 저수로 형태 변화에 따른 유동장에 대해 분석한 바에 따르면, 선행 연구들에서 검토된 이차류 현상이 발생하였음을 확인한 한편, 고수부지 내 유수단면적 확대에 따라 최고유속분포 지점이 이동하는 현상을 확인할 수 있었다. 궁극적으로 저수로 폭 변화가 흐름에 영향을 끼쳐 궁극적으로 하천설계에 중요한 요소인 수충부의 위치와 그 영향 정도를 파악하는 것이 필요하다고 판단된다.

저수로 물길 복원을 통한 서식처 공간 변화 연구 (A Case Study of the Habitat Changes due to the Restoration of Low-Flow Channel)

  • 최종근;최흥식;최병웅
    • Ecology and Resilient Infrastructure
    • /
    • 제6권1호
    • /
    • pp.58-68
    • /
    • 2019
  • 본 연구는 저수로 물길 복원 조성을 통한 복원이 어류 서식처에 미치는 영향을 파악하기 위하여 원주천을 대상으로 물리서식처 분석을 수행하였다. 대상 어종은 원주천 중 상류에 서식하는 우점종인 참갈겨니를 대상으로 하였다. 흐름 분석은 2차원 모형인 River2D 모형을 사용하였으며, 서식처 분석은 서식처 적합도 곡선을 이용하여 서식처의 양과 질을 산정하는 서식처 적합도 모형을 사용하였다. 먼저 저수로 복원을 위하여 대상 구간의 강턱유량을 통하여 저수로 물길을 확인하고, 이를 통해 수리학적으로 유리한 저수로 단면을 설계하였다. 또한, 저수로 구간에 거석, 여울/소 구조, 그리고 단면 확폭을 통하여 다양한 복원기법을 적용하였다. 그 결과 수리학적으로 유리한 저수로 물길 복원 조성의 경우 현상태의 하폭보다 감소하였기 때문에 서식처가 악화되는 것으로 나타났다. 그러나 다양한 복원 기법을 적용하였을 때 서식처는 약 11% 정도 향상되는 것으로 나타났다.