• Title/Summary/Keyword: Low energy building

Search Result 533, Processing Time 0.025 seconds

Response of circular footing on dry dense sand to impact load with different embedment depths

  • Ali, Adnan F.;Fattah, Mohammed Y.;Ahmed, Balqees A.
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.323-336
    • /
    • 2018
  • Machine foundations with impact loads are common powerful sources of industrial vibrations. These foundations are generally transferring vertical dynamic loads to the soil and generate ground vibrations which may harmfully affect the surrounding structures or buildings. Dynamic effects range from severe trouble of working conditions for some sensitive instruments or devices to visible structural damage. This work includes an experimental study on the behavior of dry dense sand under the action of a single impulsive load. The objective of this research is to predict the dry sand response under impact loads. Emphasis will be made on attenuation of waves induced by impact loads through the soil. The research also includes studying the effect of footing embedment, and footing area on the soil behavior and its dynamic response. Different falling masses from different heights were conducted using the falling weight deflectometer (FWD) to provide the single pulse energy. The responses of different soils were evaluated at different locations (vertically below the impact plate and horizontally away from it). These responses include; displacements, velocities, and accelerations that are developed due to the impact acting at top and different depths within the soil using the falling weight deflectometer (FWD) and accelerometers (ARH-500A Waterproof, and Low capacity Acceleration Transducer) that are embedded in the soil in addition to soil pressure gauges. It was concluded that increasing the footing embedment depth results in increase in the amplitude of the force-time history by about 10-30% due to increase in the degree of confinement. This is accompanied by a decrease in the displacement response of the soil by about 40-50% due to increase in the overburden pressure when the embedment depth increased which leads to increasing the stiffness of sandy soil. There is also increase in the natural frequency of the soil-foundation system by about 20-45%. For surface foundation, the foundation is free to oscillate in vertical, horizontal and rocking modes. But, when embedding a footing, the surrounding soil restricts oscillation due to confinement which leads to increasing the natural frequency. Moreover, the soil density increases with depth because of compaction, which makes the soil behave as a solid medium. Increasing the footing embedment depth results in an increase in the damping ratio by about 50-150% due to the increase of soil density as D/B increases, hence the soil tends to behave as a solid medium which activates both viscous and strain damping.

Evaluation of the Physical Properties for Lightweight Bricks Made from Sewage Sludge and Wasted Glass (하수슬러지로 제조한 경량 벽돌의 물성평가)

  • Jeong, Jae-Ah;Son, Yeong-Geum;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.781-784
    • /
    • 2013
  • Ocean dumping of sewage sludge is banned. Therefore, it is needed to develop alternative treatment method. Sewage sludge and waste glass are used to prepare lightweight brick. Large amount of energy is consumed to prepare building material, because of its high preparation temperature, or above $1,200^{\circ}C$. We study to prepare lightweight brick, using sewage sludge and waste glass as raw materials in this research. Lightweight brick was made at low temperature of below $800^{\circ}C$ to reduce $CO_2$ emission by geopolymer technique. Calcination temperature, mixing ratio of sewage sludge/waste glass and water glass/water were discussed to evaluate their effect on the brick prepared. In this study, the optimal conditions for preparing bricks was $750^{\circ}C$ of firing temperature, 1.5 of mixing ratio for water glass/water and 10 : 90 wt% of sewage sludge/waste glass. At this condition, compressive strength and specific gravity of brick prepared were 5.1 MPa and 0.46, respectively. These values satisfy the criteria on a lightweight brick.

A Study on the Criteria for Demarcating Ecological Types of Urban Areas by the Affection of Ecosystems - Case Study in Gangdong-Gu, Seoul - (시가화지역 생태적 유형구분을 위한 관련지표 특성 연구 - 서울시 강동구를 사례로 -)

  • Hong, Suk-Hwan;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.2
    • /
    • pp.24-31
    • /
    • 2008
  • Studies for demarcation of urban areas by ecological type have been developed, but the demarcation of urban areas by ecological perception is thus far dependent on artificial land use. Therefore, the purpose of this study is to find factors that account for the urban area ecosystems by surveying a variety of ecosystem factors. By land use type, the urban area of Gangdong District, Seoul was defined. Then ecological factors in each polygon were surveyed. Ecological factors are associated with energy use(building coverage ratio, floor area ratio and ground temperature), water circulation(biotope area factors and impermeable pave ratio) and biological diversity(bird appearance index and green area ratio). The correlation between each factor was analyzed. The results indicate that urban ground temperature is divided into three groups(high, middle and low) by the biotope area factor. The bird population is divided into two groups(abundant and scarce) by the green area ratio. Therefore, demarcating the urban areas by ecological type is applicable to the biotope area factor and green area ratio.

Test Results on the Type of Beam-to-Column Connection using SHN490 Steel (SHN490강종의 보-기둥 접합부 형태에 따른 실험적 연구)

  • Kim, So Yeong;Byeon, Sang Min;Lee, Ho;Shin, Kyung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.311-321
    • /
    • 2015
  • In this study, an experimental study to evaluate the seismic performance of beam-to-column connection for medium and low-rise building was conducted. Five connections using SHN490 steel were made with test variables such as flange welded or bolted, web welded or bolted. Specimen SHN-W-W is web welded and flange welded type. Specimen SHN-W-B is web welded and flange bolted type. Specimen SHN-B-W is web bolted and flange welded type. Specimen SHN-B-B is web bolted and flange bolted type. Specimen SHN-EP is a connection with the end plate to the beam ends. Cyclic loadings was applied at the tip of beam following KBC2009 load protocol. The load vs rotation curves for different connection are shown and final failure mode shapes are summarized. The connections are classified in terms of stiffness and strength as semi-rigid or rigid connection. Energy dissipation capacities for seismic performance evaluation were compared.

Effects of Milk Replacer and Ambient Temperature on Growth Performance of 14-Day-Old Early-Weaned Pigs

  • Heo, K.N.;Odle, J.;Oliver, W.;Kim, J.H.;Han, In K.;Jones, E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.908-913
    • /
    • 1999
  • This experiment was conducted in three trials to evaluate optimal ambient temperature for a novel milk replacer feeding system designed for early-weaned pigs, compared to commercial dry diets fed within a conventional hot nursery. A total of 165 PIC genotype pigs were weaned at $13.89{\pm}0.7$ days of age and allotted to one of two dietary treatments in three trials based on weight and litter origin. Each trial consisted of pigs fed dry diets (DD) and pigs fed milk replacer (MR) which was offered in one of 3 different ambient temperatures. Pigs fed milk replacer were housed in a specialized nursery building in which one half of each pen contained an enclosed hover that was thermostatically maintained at $32^{\circ}C$ while the exterior ambient temperature (where milk was fed) was set at either 17 (trial 1), 24 (trial 2) or $32^{\circ}C$ (trial 3). Pigs fed dry diets with the conventional nursery were maintained at $30^{\circ}C$ for each trial. From d 21 to d 49, all pigs were fed DD within a standardized hot nursery environment. During the first week (d 14-21), pigs fed MR showed increased ADG from 214% to 228% over control pigs fed DD (p<0.001), regardless of ambient temperature. As ambient temperature was increased from 17 to 24 to $32^{\circ}C$, ADG of MR-fed pigs was increased by 214%, 220% and 228% over those of pigs fed DD, respectively. ADFIs of MR-fed pigs at $17^{\circ}C$, $24^{\circ}C$, and $32^{\circ}C$ compared with pigs fed DD were increased by 108%, 139% and 164% from d 14 to d 21, respectively. Fed efficiency (G/F) of MR-fed pigs at $17^{\circ}C$, $24^{\circ}C$, and $32^{\circ}C$ compared with pigs fed DD were 199%, 162% and 139% of those of pigs fed DD, respectively. As ambient temperature increased, diarrhea scores showed a slight tendency to increase. The advantage of MR feeding was greater when the ambient temperature was higher, but G/F was impaired with increased ambient temperature. We conclude that ambient temperature within the specialized nursery influenced behavior, MR feed intake, and probably piglet energy expenditure. There were no differences between MR-fed and DD-fed pigs for ADG, ADFI and G/F in the subsequent growth period (d 21 to d 49, p>0.05). Maximal advantage of MR feeding was obtained at the intermediate ($24^{\circ}C$) ambient temperature during the overall period (p<0.05). Results from this experiment indicate that a milk replacer feeding system utilized in the early postweaning period can maximize pig growth performance, and that ADG, ADFI and G/F were affected by different ambient temperatures within MR-fed pigs. The high or low temperatures could not support the maximal growth of pigs fed MR.

A Study on the Minimum Engine Propulsion Power Required for Safe Navigation of Small and Medium Ships (중소형 선박의 안전항해를 위한 주기관 최소출력에 관한 연구)

  • Kang, Suk-Young;Ahn, Young-Joong;Kim, Seung-Yeon;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.415-420
    • /
    • 2018
  • The Energy Efficiency Design Index (EEDI) introduced by the Marine Environment P rotection Committee(MEPC) in International Maritime Organization(IMO) has significantly assisted in regulating CO2 emissions. However, in adverse weather conditions, it can lead to accidents due to slow steaming of vessels and low engine propulsion power. In response to this issue, the MEPC presented guidelines for the minimum propulsion power of the main engine for maintaining the course of vessels in adverse weather conditions. However, the guidelines are only applicable for vessels with a deadweight of 20,000 tons, leaving out small and medium ships. This study evaluated vessels subject to the guidelines of minimum propulsion power and proposed revised guidelines. In addition, relevant cases of marine accidents were investigated with the aim of investigating the minimum propulsion power of main engine for medium and small ships not covered by the guidelines. In order to achieve this, engine propulsion power was analyzed according to the size of the affected vessels. The results obtained from this study could be used as a minimum power criterion that can be considered for ship building to reduce marine accidents in adverse weather for small and medium ships.

Quantification of the CO2 Footprint in Residential Construction

  • Don Mah;Juan D. Manrique;Haitao Yu;Mohamed Al-Hussein;Reza Nasseri
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.525-536
    • /
    • 2009
  • The current residential process adheres to a traditional method of construction involving wood framing on-site on poured concrete foundations which has been widely applied in North America. A conventional residential construction process can include seventeen distinct stages ranging from stake-out to pre-occupancy inspection. The current practice possesses short comings including high construction material wastes, long scheduling timelines, adverse weather conditions, poor quality, low efficiencies and negative environmental impacts from transportation and equipment use. Over CAN $5 billion dollars was spent in the construction sector during 2007 in Canada. Previous findings in CO2 emissions during the construction process of a conventional dwelling emphasize more than 45 tonnes of CO2 emissions. Hence, in Alberta alone during 2007, almost 50,000 residential units would release more than two million tonnes of CO2. These numbers demonstrate the economical and environmental impact in building construction and its relationship with CO2 emissions. The aim of this paper is to quantify the CO2 emissions from the current residential construction process in order to establish the baseline for CO2 emission reduction opportunities. The quantification collection methodology will be approached by identifying the seventeen various stages of construction and quantifying the contributions of CO2 from specific activities and their impacts of work for each stage. The approach of separating these into separate stages for collection will allow for independent opportunities for analysis from various independent contractors from the entire scope of work. The use of BIM will be implemented to efficiently quantify CO2 emissions. Based on the CO2 quantification baseline, emission reduction opportunities such as an industrialized construction process will be introduced that allows homebuilders to reduce the environmental and economical impact of home construction while enabling them to produce higher quality, more energy efficient homes in a safer and shorter period of time.

  • PDF

Operational Ship Monitoring Based on Multi-platforms (Satellite, UAV, HF Radar, AIS) (다중 플랫폼(위성, 무인기, AIS, HF 레이더)에 기반한 시나리오별 선박탐지 모니터링)

  • Kim, Sang-Wan;Kim, Donghan;Lee, Yoon-Kyung;Lee, Impyeong;Lee, Sangho;Kim, Junghoon;Kim, Keunyong;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.379-399
    • /
    • 2020
  • The detection of illegal ship is one of the key factors in building a marine surveillance system. Effective marine surveillance requires the means for continuous monitoring over a wide area. In this study, the possibility of ship detection monitoring based on satellite SAR, HF radar, UAV and AIS integration was investigated. Considering the characteristics of time and spatial resolution for each platform, the ship monitoring scenario consisted of a regular surveillance system using HFR data and AIS data, and an event monitoring system using satellites and UAVs. The regular surveillance system still has limitations in detecting a small ship and accuracy due to the low spatial resolution of HF radar data. However, the event monitoring system using satellite SAR data effectively detects illegal ships using AIS data, and the ship speed and heading direction estimated from SAR images or ship tracking information using HF radar data can be used as the main information for the transition to UAV monitoring. For the validation of monitoring scenario, a comprehensive field experiment was conducted from June 25 to June 26, 2019, at the west side of Hongwon Port in Seocheon. KOMPSAT-5 SAR images, UAV data, HF radar data and AIS data were successfully collected and analyzed by applying each developed algorithm. The developed system will be the basis for the regular and event ship monitoring scenarios as well as the visualization of data and analysis results collected from multiple platforms.

Estimation of Domestic Greenhouse Gas Emission of Refrigeration and Air Conditioning Sector adapting 2006 IPCC GL Tier 2b Method (국내 냉동 및 냉방부문 온실가스 배출량 산정 - 2006 IPCC GL Tier 2b 적용 -)

  • Shin, Myung-Hwan;Lyu, Young-Sook;Seo, Kyoung-Ae;Lee, Sue-Been;Lim, Cheolsoo;Lee, Sukjo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2012
  • The Government of South Korea has continued its effort to fixate virtuous circle of economic growth and climate change response to cope with international demands and pressure to commitment for greenhouse gas reduction effectively. Nationally, Korean Government has established "Enforcement of the Framework Act on Low carbon, Green Growth"(2010. 4. 13) to implement national mid-term GHG mitigation goal(30% reduction by 2020 compare to BAU), which established the foundation for phased GHG mitigation by setting up the sectoral and industrial goal, adopting GHG and Energy Target Management System. Also, follow-up measures are taken such as planning and control of mid-term and short-term mitigation target by detailed analysis of potential mitigation of sector and industry, building up the infrastructure for periodic and systematic analysis of target management. Likewise, it is required to establish more accurate, reliable and detailed sectoral GHG inventory for successfully establishment and implement the frame act. In comparison to the $CO_2$ emission, Especially fluorinated greenhouse gases (HFCs, PFCs, $SF_6$) are lacking research to build the greenhouse gas inventories to identify emissions sources and collection of the applicable collection activities data. In this study, with the refrigeration and air conditioning sector being used to fluorine refrigerant(HFCs) as the center, greenhouse gas emission estimation methodology for evaluating the feasibility of using this methodology look over and mobile air conditioning, fixed air conditioning, household refrigeration equipment, commercial refrigeration equipment for the greenhouse gas emissions were calculated. First look at in terms of methodology, refrigeration and air conditioning sector GHG emissions in developing country-specific emission factors and activity data of the industrial sector the construction of the DB is not enough, it's 2006 IPCC Guidelines Tier 2a (emission factor approach) rather than the Tier 2b (mass balance approach) deems appropriate, and each detail by process, sectoral activity data more accurate, if DB is built Tier 2a (emission factor approach) can be applied will also be judged. Refrigeration and air conditioning sector in 2009 due to the use of refrigerant greenhouse gas emissions ($CO_2eq.$) assessment results, portable air conditioner 1,974,646 ton to year, fixed-mount air conditioner 1,011,754 ton to year, household refrigeration unit 4,396 ton to year, commercial refrigeration equipment 1,263 ton to year was estimated to total 2,992,037 tons.

Nutrition Survey in Koje Island (거제도(巨濟島) 주민(住民)의 영양실태조사(營養實態調査))

  • Oh, Seoung-Ho;Chang, Soo-Kyung;Park, Michael Myung-Yun
    • Journal of Nutrition and Health
    • /
    • v.10 no.4
    • /
    • pp.43-58
    • /
    • 1977
  • Kojedo is the second largest island in Korea and a total population of 115,500 is living on the island of 394.69 sq. km. Under the direction of three nutrition professors, nutrition surveys in two villages in Kojedo, namely Siljun Ri in Hachung Myon and Soowol Ri in Shinhyun Myon, were carried by 30 college senior students majoring in nutrition from August to 20 August 1977. From a total of 176 households of the two villages, 67 households were randomly selected and 390 family members of the households were subjcets of the nutrition surveys. The precise weighing method was used in evaluating the kinds of foods and nutrient intakes of the subjects for three consecutive days. Thirty-seven pre-school children aged between 3 to 6 years and 27 fertile women were examined for biochemical findings and physical status. The main purposes of the surveys are to provide baseline data on nutrition in Kojedo Island for the Kojedo Community Development Project and to compare the nutritional status of the villages of Siljun Ri and Soowol Ri. Siljun Ri is located in the pilot project area of the Koiedo Community Health Project sponsored since December 1970 by the Christian Medical Commission of the World Council of Churches. While Soowol Ri is a control village for comparison. The results obtained are summarized as follows: Food Intake The average food intake per person per day in Siljun Ri, 1064 grams (91.7% in vegetable foods and 7.6% in animal foods) was 90 grams more than that of Soowol Ri, 974 grams (92.8% in vegetable foods and 5.9% in animal foods). However, the food intake per pre-school child in Siljun Ri, 485 grams (92.6% from vegetable foods and 6.4% from animal foods) was 21 grams lower than that of the Soowol Ri, 506 grams (88.5% from vegetable foods and 6.5% from animal foods). The average intake of beans was 16 grams(1.5% out of the total food intake) in Siljun Ri and 21 grams(2.2% of the total food intake)in Soowol Ri. The villagers should be guided for more consumption of soybeans to improve the quality of protein intake from vegetable foods. Nutrient Intake The adult intake in Siljun Ri and Soowol Ri were 2,529 kcal and 2,511 kcal respectively. The average energy intake of pre-school childen in Siljun Ri was 948 kcal and that for adult and 1,500 kcal for childen aged between 4 to 6 years-given by the Korea FAO Association, the diets in both villages were not adequate. Average daily protein intake of the subjected adult in Siljun Ri was 78.4 grams and that of Soowol Ri was 76.2 grams, while pre-school children took 30.7 grams in the former village and 31.7 grams in the latter village per child per day. The protein intake in both villages were lower than the recommended allowances, 80 grams for adult and 45 grams for $4{\sim}6$ years childen, and animal protein intake of the all subjects was very much lower than the RDA. The main charecter of the diet has been found low in quality of protein and high in carbohydrate. The calcium intakes of the pre-school children in both villages, 251.9 milligrams in Siljun Ri and 218.8 milligrams in Soowol Ri, were very much lower than the recommended allowance of 500 milligrams per day. It is apparent that the diet for children should be supplemented with calcium. Among the vitamin group, the daily average intakes of vitamin A and $B_{2}$(thiamine), $B_{2}$(riboflavin), C(ascorbic acid), and niacin were not adequate for the children in both villages. Especially the intake of riboflavin, 0.4 milligrams in both village children, was much lower than the RDA, 0.9 milligrams per day. Physical Characteristics Average height, weight, chest and head circumference of the pre-school children in both villages were similar to those of the Korean standard given by the Korean Paediatrics Association except that the average height of pre-school boys in Siljun Ri was 8 cm higher than the Korean standard of 105 cm. The mean values of upper arm circumference and skinfold thickness of pre-school boys in both villages were the same, 15.4 cm for upper arm circumference and 6.8 mm for skinfold thickness, but the mean values of those of the girls in Siljun Ri were higher than those of pre-school grils in Soowol Ri. Biochemical Findings Avera ge hemogobin value of boys and girls in both villages was the same, 11.1 grams per 100 ml of blood. The incidence of anemia (Hb value below 11g/100ml) was similar in both viltagesr 36.4% for boys and 50% for girls in Siljun Ri and 37.5% for boys and 50% for girls in Soowol Ri. Average hemoglobin values of fertile women were 10.7g% in Siljun Ri and 10.8% in Soowor Ri. The incidences of anemia(Hb valre brlow 12g/100ml) were 100% in Siljun Ri and 86.7% in Soowol Ri. The anemia of these subjects may be caused mainty low intake of good quality protein and iron intake from vegetable food. Recommendation In general, the nutritional status of a community health pilot village is not higher than that of control village due to the lack of nutrition improvement guldance services. Nutrition education should be delivered to the villagers as a main part of the health education artivities. The emphasis should be on building better health through bttter food habits and better food production as well as on preventing malnutrition and diseasrs. It can be an invaluable part of community developnent. Since nutrition is considered to be at least one-half of MCH care, no village or home visits should be made without careful provision for teaching and demoastrating something simple and practical on nutrition. The nurse, midwife, and village health worker should be the chief promoters of nutrition.

  • PDF