• Title/Summary/Keyword: Low energy building

Search Result 535, Processing Time 0.027 seconds

Policy Directions to Build on Nature-Friendly Park Facilities - Based on an Evaluation on the Nature-Friendliness of Park Facilities in National Parks - (자연친화적인 공원시설 설치를 위한 정책방향 - 국립공원 공원시설의 자연친화성 평가를 근거로 -)

  • Park, Chang-Sug;Bae, Min-Ki;Kim, Tae-Jin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.1-12
    • /
    • 2009
  • The purpose of this research was to propose policy directions for the design and construction of nature-friendly park facilities (PF) in national parks. In order to do that, nature-friendliness evaluation indicators(NEIs) used in green building rating systems and related articles were reviewed. After the initial literature review was complete, NEIs for park facilities based on location, design, construction, operation, and management sectors were developed. Data was obtained through a questionnaire completed by 79 managers at 19 national parks in Korea in 2008. The answers were analyzed using descriptive statistical methods, a t-test, a multi-dimensional analysis, and a factor analysis. This research found that: 1) The results indicated that based on relative weight calculation, the location condition was evaluated as the most important; 2) The evaluation results regarding the degree of nature-friendliness of park facilities showed that location condition was ranked higher than design and construction--in addition, the evaluated values of indicators related to energy efficiency were ranked the lowest; 3) the level of nature-friendliness of shelter was given the highest level, but resting facility was the lowest level; 4) Overall, park facilities at Mt. Seorak, Mt. Odae, and Taean Coast national parks showed high levels of nature-friendliness. But park facilities at Mt. Gyeongju and Mt. Songni national parks showed low levels of nature-friendliness. The results of this research shall contribute to the establishment of tailor-made management policies, the development of detailed guidelines for increased energy efficiency and visitor satisfaction, and the preservation of ecosystems and natural resources in Korea's national parks.

Numerical Simulation of Flow Characteristics behind a Circular Patch of Vegetation using a Two-Dimensional Numerical Model (2차원 수치모형을 이용한 원형군락 하류의 흐름특성 수치모의)

  • Kim, Hyung Suk;Park, Moonhyeong
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.11
    • /
    • pp.891-903
    • /
    • 2015
  • This paper presents numerical simulations of flow around a circular patch of vegetation using a depth-averaged two-dimensional numerical model which is capable of simulating flow structure in vegetated open channel. In order to account for vegetation effect, drag force terms are included in governing equations. Numerical simulations are conducted with various solid volume fractions (SVF). Flow passes through a circular patch and low velocity region, which is called wake region, is formed downstream of the patch. When SVF is larger than 0.08, a recirculation is observed. The location of the recirculation is moved further downstream as SVF decreases. Von-$K{\acute{a}}rm{\acute{a}}n$ vortex street is developed beyond the wake region due to interaction between two shear layers induced by a circular patch of vegetation. The vortex is developed as SVF is larger than 0.08, and the location of the vortex is consistent with the maximum of turbulence kinetic energy. The location of the peak of turbulence kinetic energy is moved further downstream as SVF decreases.

Purity of γ-Dicalcium Silicate with Synthetic and Raw Materials Conditions (합성 및 원료 조건에 따른 γ-C2S의 순도)

  • Lee, Seok-Hee;Cho, Hyeong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.2
    • /
    • pp.123-128
    • /
    • 2020
  • γ-dicalcium silicate(γ-C2S) is known as a polymorphism of belite. Due to its high CO2 fixing capacity and the production process with low CO2 emission, γ-C2S has attracted more attention of researchers. For the further development of γ-C2S applications in construction industry, this study aims to investigate the method for synthesizing high purity of γ-C2S. The influence of raw materials and calcination temperatures on the purity of γ-C2S was evaluated. Several Ca bearing materials were selected as the calcium source, the materials which's main component is SiO2 were used as the silicon source. Raw materials were mixed and calcined under different temperatures. The results revealed that the highest purity could be obtained using Ca(OH)2 and SiO2 powder as raw materials. In addition, a relatively economic synthesis method using natural mineral materials-limestone and silica sand as raw materials were developed for the practical application. The purity of synthetic γ-C2S was recorded up to 77.6%.

Examining Diurnal Thermal Variations by Urban Built Environment Type with ECOSTRESS Land Surface Temperature Data: Evidence from Seoul, Korea (도시 건조환경 유형에 따른 서울시 주간 지표면 온도 변동성 분석: ECOSTRESS 데이터의 활용)

  • Gyuwon Jeon;Yujin Park
    • Journal of the Korean Regional Science Association
    • /
    • v.40 no.2
    • /
    • pp.107-130
    • /
    • 2024
  • Urban land surface temperature (LST) change is a major environmental factor that affects the thermal comfort, energy consumption, and health of urban residents. Most studies that explored the relationship between LST and urban built-environment form analyzed only midday LST. This study explores the diurnal variation of summertime LST in Seoul using ECOSTRESS data, which observes LST at various times of the day and analyzes whether the LST variation differs by built environment type. Launched in 2018, ECOSTRESS operates in a non-sun-synchronous orbit, observing LST with a high resolution of 70 meters. This study collected data from early morning (6:25) to evening (17:26) from 2019 to 2022 to build time-series LST. Based on greenery, water bodies, and building form data, eight types of Seoul's built environment were derived by hierarchical clustering, and the LST fluctuation characteristics of each cluster were compared. The results showed that the spatial disparity in LST increased after dawn, peaked at noon, and decreased again, highlighting areas with rapid versus stable LST changes. Low-rise and high-rise compact districts experienced fast, high temperature increases and high variability, while low-density apartments experienced moderate LST increases and low variability. These results suggest urban forms that can mitigate rapid daytime heating.

An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation (노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가)

  • Lee, Jeongmin;So, Wonho;Cho, Kyungchan;Choi, Dongnyeok;Lee, Kwon-yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.287-297
    • /
    • 2020
  • This study examined ways of improving the internal insulation performance of aging university buildings, and to enhance the convenience of occupants in university buildings and the insulation effect of aging buildings. This research was conducted to solve the problem of continuous requests for improving the insulation performance of office workers in the Nehemiah Hall building of Handong University. The results showed that the internal temperature of Nehemiah Hall was low compared to the internal temperature of the adjacent building. Considering the characteristics of the building, the university chose insulating materials under the theme of internal insulation. The experiment was conducted by installing internal wall insulation used in the market by producing a model room that miniaturized the university professor's office. Based on the experimental results, an economic evaluation was conducted to analyze the insulation effect by measuring the heating time and actual heat transmission coefficient. An economic evaluation was conducted by experiment and theory and on a winter and summer basis. According to the research, when an Isopink (30 T) was introduced as an internal insulation material in 60 offices of Nehemiah Hall, it could save up to 1,071,600 won in total during the winter season and 109,200 won during the summer season.

A Case Study on Electronic Recognition Sensor for Underground Facility Management System (지중 매설물 이력 관리 시스템 개발을 위한 전자인식기의 현장 적용성 검증 연구)

  • Jung, YooSeok;Kim, Soullam;Kim, Byungkon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.777-785
    • /
    • 2021
  • Many utility lines are buried underground to provide various functions of the city. Because historical records are not managed systematically, damage has occurred during excavation. In addition, the demand for an underground facility management system is increasing as the aerial underground project is progressing. By attaching an electronic recognition sensor to an underground facility, such as pipelines, the management history and site conditions can be carefully managed. Therefore, in this study, electronic recognition sensors, such as BLE Beacon, UHF RFID, geomagnetic sensor, and commercial marker, were tested to analyze the strengths, weaknesses, and field applicability through a pilot project. According to the limited research results collected through two pilot projects, the installation depth is most important to demonstrate the performance of the electronic reader. In addition, because it should be used in urban areas, the influence of environmental interference should be minimized, and there should be no performance degradation over time. In the case of the geomagnetic recognizer, the effect of environmental interference was large, and performance degradation occurred over time using the BLE Beacon. In the field situation, where the installation depth can be controlled to less than 40cm, the utility of the battery-free UHF RFID was the best.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis (비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가)

  • Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.9-20
    • /
    • 2014
  • Steel intermediate moment frames (IMFs) have been generally used as seismic load resisting systems (SLRSs) of a building to provide resistances against strong ground shaking. However, most of low and mid-rise steel buildings in Korea were constructed during pre-seismic code era or before the introduction of well-organized current seismic codes. It has been recognized that the seismic performance of these steel IMFs is still questionable. In order to respond to such a question, this study quantitatively investigates the seismic capacities of steel IMFs. Prototype models are built according to the number of stories, the levels of elastic seismic design base shear and the ductilities of structural components. Also, the other prototype models employing hysteretic energy dissipating devices (HEDDs) are considered. The collapse mechanism and the seismic performance of the prototype models are then described based on the results obtained from nonlinear-static and incremental-dynamic analyses. The seismic performance of the prototype models is assessed from collapse margin ratio (CMR) and collapse probability. From the assessment, the prototype model representing new steel IMFs has enough seismic capacities while, the prototype models representing existing steel IMFs provide higher collapse probabilities. From the analytic results of the prototype models retrofitted with HEDDs, the HEDDs enhance the seismic performance and collapse capacity of the existing steel IMFs. This is due to the energy dissipating capacity of the HEDDs and the redistribution of plastic hinges.

Development of a Movable Drawer Type Light-Shelf with Adjustable Depth of the Reflector (반사판의 폭 조절이 가능한 서랍형 타입의 가동형 광선반 개발 연구)

  • Kim, Dasom;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.343-349
    • /
    • 2016
  • Due to the recent increase in lighting energy consumption in buildings, there are a growing number of studies seeking solutions this problem. The effectiveness of light-shelves as natural lighting systems to solve this problem has been recognized, and various studies regarding such systems are being carried out currently. However, the lighting efficiency of light-shelves decreases if illumination intensity is low-such as at night time, and it also obstructs the views of building occupants. Therefore, the purpose of this study is to examine a movable drawer type light-shelf which allows for the width of the reflector to be adjusted and verify its performance through a simulated test-bed. The following conclusions were reached. 1) The purpose of this study is to solve the problem previously associated with the light-shelf system- of obstructed views-by responding to external environments and minimizing the width of the light-shelf at night time when the efficiency of the light-shelf declines. 2) The proper variables of the movable drawer type light-shelf which enables the width adjustment of the reflector were ascertained in this study according to four solar terms : a width of 0.6 m at an angle of $20^{\circ}$, a width of 0.4m with an angle of $20^{\circ}$, and a width of 0.1 m with an angle of $20^{\circ}$ were determined for the summer solstice, fall/spring equinoxes, and winter solstice respectively; revealing that width adjustment of the light-shelf is a significant factor. 3) The movable drawer type light-shelf which enables${\backslash}$width adjustment of the reflector suggested in this study can reduce the lighting energy consumption by 18.7% and 14.3% in comparison to previous light-shelves with a fixed width of 0.3 m and 0.6m, indicating that it is effective for saving energy.