Low-dose Epidermal Growth Factor Receptor (EGFR)-Tyrosine Kinase Inhibition of EGFR Mutation-positive Lung Cancer: Therapeutic Benefits and Associations Between Dosage, Efficacy and Body Surface Area

  • Hirano, Ryosuke;Uchino, Junji;Ueno, Miho;Fujita, Masaki;Watanabe, Kentaro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.785-789
    • /
    • 2016
  • A key drug for treatment of EGFR mutation-positive non-small cell lung cancer is epidermal growth factor receptor-tyrosine kinase inhibitor (EGFR-TKI). While the dosage of many general anti-tumor drugs is adjusted according to the patient body surface area, one uniform dose of most TKIs is recommended regardless of body size. In many cases, dose reduction or drug cessation is necessary due to adverse effects. Disease control, however, is frequently still effective, even after dose reduction. In this study, we retrospectively reviewed the characteristics of 26 patients at Fukuoka University Hospital between January 2004 and January 2015 in whom the EGFR-TKI dose was reduced with respect to progression free survival and overall survival. There were 10 and 16 patients in the gefitinib group and the erlotinib group, respectively. The median progression-free survival in the gefitinib group and the erlotinib group was 22.4 months and 14.1 months, respectively, and the median overall survival was 30.5 months and 32.4 months, respectively. After stratification of patients by body surface area, the overall median progression-free survival was significantly more prolonged in the low body surface area (<1.45 m2) group (25.6 months) compared to the high body surface area (>1.45 m2) group (9.7 months) (p=0.0131). These results indicate that low-dose EGFR-TKI may sufficiently control disease without side effects in lung cancer patients with a small body size.

Determination of Environmental Radiation Dose Rate in the Southeastern Korea (우리나라 남동지방(南東地方)의 환경방사선(環境放射線) 선량율(線量率)의 결정(決定)(1980년도(年度)))

  • Rho, Chae-Shik;Lee, Hyun-Duk
    • Journal of Radiation Protection and Research
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1980
  • A portable count-ratemeter and a thermoluminescent detector ($CaSO_4:Dy$) have been used to obtain total gamma dose rates at approximately 50 locations during the course of several survey trips in the southeastern Korea. The purposes of these measurement were to provide a future reference data and to establish the approximate range of population exposure to the natural environmental radiation. The natural levels encountered ranged from a low of 14.6 microroentgen per hour to a high of 18.9 microroentgen per hour with a mean of $16.3{\pm}1.0$ microroentgen per hour. Among these results are the relatively high natural dose rate levels in the Masan area and Yangsan-Tongdosa area with the relatively low natural dose rate levels in the Gyeongsan-Cheongdo area and the Samrangjin-Jinyeong-Gimhae area.

  • PDF

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

A Comparison between Effects of Anorexia Induced by Consecutive Low-Dose Cisplatin and High-Dose Cisplatin on Hindlimb Muscles of Rats (시스플라틴에 의해 유발된 식욕부진이 쥐의 뒷다리근에 미치는 영향: 저용량 연속투여요법과 고용량 투여요법 간의 비교)

  • Kim, Jin-Il;Choe, Myoung-Ae
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.1
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effects of anorexia induced by consecutive low-dose and high-dose of cisplatin (CDDP) on the hindlimb muscles of rats. Methods: Male Sprague-Dawley rats were assigned to three groups: Control group (C) received a saline (the same dose and duration as the low CDDP group), the high-dose cisplatin (High CDDP) group received a single 5 mg/kg dose of cisplatin, the consecutive low-dose cisplatin (Low CDDP) group had 1 mg/kg of cisplatin administered for five consecutive days. On the 8th day the soleus and gastrocnemius muscles were dissected. Body weight, food intake, activity, muscle weight, Type I, II fiber cross-sectional area (CSA) of the dissected muscles were measured. Results: Body weight, food intake, muscle weight and Type I, II fiber CSA of the High CDDP and Low CDDP groups were significantly less than the C group. The High CDDP group showed significant decreases, compared to the Low CDDP group, in body weight, food intake, activity score, muscle weight and Type I, II fiber CSA. Conclusion: Hindlimb muscle atrophy occurs due to anorexia induced by both consecutive low-dose and high-dose cisplatin. The muscle atrophy induced by consecutive low-dose cisplatin is less apparent than high-dose cisplatin.

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

Effect of Chromium Picolinate on Glucose Tolerance and Insulin Sensitivity in the Type I and II Diabetic Rats (1형과 2형 당뇨모델 흰쥐에서 Chromium Picolinate의 당내성과 인슬린 감수성에 대한 영향)

  • 신현진;홍정희;고현철;신인철;강주섭;최호순;김태화;김동선;엄애선
    • Biomolecules & Therapeutics
    • /
    • v.9 no.4
    • /
    • pp.277-281
    • /
    • 2001
  • Chromium is an essential nutrient and participates in glucose and lipid metabolism in human beings and animals. The present study was conducted to assess the effects of chromium picolinate (Cr-pic) on glucose tolerance and insulin sensitivity in type I and ll diabetic rats. The experimental groups were type I diabetic (streptozotocin-induced: 40 mg/kg, i.p.) and type II diabetic (Goto-Kakizaki rats) models. Each group was subdivided into control. low-dose and high-dose of Cr-pic treated groups. The Cr-pic was orally administered with Cr-pic (100 mg/kg for low dose group and 200 mg/kg for high dose group) for 4 weeks. And then we performed intraperitoneal glucose tolerance test (IPGTT) and insulin sensitivity test (ITT). The glucose tolerance test was carried out by inection of glucose (2 g/kg, i.p.). The peripheral insulin sensitivity test was con- ducted by injection of insulin (5 units/kg, s.c.) and glucose. We performed determining of blood glucose concentration at 0, 10, 30, 60, 90, and 120 min using automated glucose analyzer. The plasma insulin concentration was determined by rat insulin EIA kit. Administration of Cr-pic improved weight gain in all group s with higher significant in the low-dose group. There was no significance between the control and the Cr-pic treated groups in the area under the blood glucose curve and serum insulin concentration plots of IPGTT and peripheral ITT in type I diabetic rats. But Cr-pic treated groups showed significantly lower levels of the area under the blood glucose currie during IPGTT and ITT and the high-dose group showed less effects compared with the low-dose group in the type II diabetic rats. The plasma insulin concentration of both diabetic groups was not influenced by Cr-pic supplementation. We can conclude that chromium picolinate may improve the endogenous and exogenous insulin action and peripheral insulin sensitivity in type II diabetic rats.

  • PDF

Evaluation of Radiation Dose according to Aneurysm Size and Location during Cerebral Aneurysm Coil Embolization (뇌동맥류 코일 색전술 시술 시 동맥류 크기 및 위치에 따른 방사선량 평가)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.407-412
    • /
    • 2022
  • Cerebral aneurysm coil embolization has the advantages of accurate, low patient burden, and fast recovery time, but efforts are needed to reduce dose due to the burden of exposure radiation dose during interventional procedures. In this study, the area dose product(DAP/Gy·cm2) and fluoro time(min) according to the size of the aneurysm and the location of aneurysm were investigated according to insurance recognition regulations aneurysm classification cerebral aneurysm coil embolization. According to the research method, classification according to the size and location of the aneurysm is first, the size of the aneurysm is divided into less than 4mm, more than 4mm to less than 8mm, and more than 8mm, and second, the dose to the area based on the location site (DAP/Gy·cm2) and fluoro time(min) based on the location site were observed. As a result, the location of the cerebral aneurysm procedure was found to be the Paraclinoid site. During cerebral aneurysm coil embolization, the area dose was 107 Gy·cm2 and fluoro time was 47.41 minutes, showing lower results than domestic studies, and when comparing the area dose product with foreign studies, the area dose product results were similar to that of Turkey and Saudi Arabia. It is expected that it can be used as an objective analysis indicator to establish diagnostic reference levels (DRLs) and patient radiation defense guidelines according to the size of cerebral aneurysm and location of cerebral aneurysm procedures during interventional procedures.

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose

  • Hee Jong Ki;Bum-soo Kim;Jun-Ki Kim;Jai Ho Choi;Yong Sam Shin;Yangsean Choi;Na-Young Shin;Jinhee Jang;Kook-jin Ahn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.256-263
    • /
    • 2022
  • Objective: This study aimed to evaluate the image quality and dose reduction of low-dose three-dimensional (3D) rotational angiography (RA) for evaluating intracranial aneurysms. Materials and Methods: We retrospectively evaluated the clinical data and 3D RA datasets obtained from 146 prospectively registered patients (male:female, 46:100; median age, 58 years; range, 19-81 years). The subjective image quality of 79 examinations obtained from a conventional method and 67 examinations obtained from a low-dose (5-seconds and 0.10-μGy/frame) method was assessed by two neurointerventionists using a 3-point scale for four evaluation criteria. The total image quality score was then obtained as the average of the four scores. The image quality scores were compared between the two methods using a noninferiority statistical testing, with a margin of -0.2 (i.e., score of low-dose group - score of conventional group). For the evaluation of dose reduction, dose-area product (DAP) and air kerma (AK) were analyzed and compared between the two groups. Results: The mean total image quality score ± standard deviation of the 3D RA was 2.97 ± 0.17 by reader 1 and 2.95 ± 0.20 by reader 2 for conventional group and 2.92 ± 0.30 and 2.95 ± 0.22, respectively, for low-dose group. The image quality of the 3D RA in the low-dose group was not inferior to that of the conventional group according to the total image quality score as well as individual scores for the four criteria in both readers. The mean DAP and AK per rotation were 5.87 Gy-cm2 and 0.56 Gy, respectively, in the conventional group, and 1.32 Gy-cm2 (p < 0.001) and 0.17 Gy (p < 0.001), respectively, in the low-dose group. Conclusion: Low-dose 3D RA was not inferior in image quality and reduced the radiation dose by 70%-77% compared to the conventional 3D RA in evaluating intracranial aneurysms.