• Title/Summary/Keyword: Low distortion

Search Result 892, Processing Time 0.025 seconds

Developement of Small 360° Oral Scanner Embedded Board for Image Processing (소형 360° 구강 스캐너 영상처리용 임베디드 보드 개발)

  • Ko, Tae-Young;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1214-1217
    • /
    • 2018
  • In this paper, we propose the development of a Small $360^{\circ}$ Oral Scanner embedded board. The proposed small $360^{\circ}$ oral scanner embedded board consists of image level and transfer method changing part FPGA part, memory part and FIFO to USB transfer part. The image level and transmission mode change unit divides the MIPI format oral image received through the small $360^{\circ}$ oral cavity image sensor and the image sensor into low power signal mode and high speed signal mode and distributes them to the port and transfers the level shift to the FPGA unit. The FPGA unit performs functions such as $360^{\circ}$ image distortion correction, image correction, image processing, and image compression. In the FIFO to USB transfer section, the RAW data transferred through the FIFO in the FPGA is transferred to the PC using USB 3.0, USB 3.1, etc. using the transceiver chip. In order to evaluate the efficiency of the proposed small $360^{\circ}$ oral scanner embedded board, it has been tested by an authorized testing institute. As a result, the frame rate per second is over 60 fps and the data transfer rate is 4.99 Gb/second

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Radiation Dose Reduction in Digital Mammography by Deep-Learning Algorithm Image Reconstruction: A Preliminary Study (딥러닝 알고리즘을 이용한 저선량 디지털 유방 촬영 영상의 복원: 예비 연구)

  • Su Min Ha;Hak Hee Kim;Eunhee Kang;Bo Kyoung Seo;Nami Choi;Tae Hee Kim;You Jin Ku;Jong Chul Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.344-359
    • /
    • 2022
  • Purpose To develop a denoising convolutional neural network-based image processing technique and investigate its efficacy in diagnosing breast cancer using low-dose mammography imaging. Materials and Methods A total of 6 breast radiologists were included in this prospective study. All radiologists independently evaluated low-dose images for lesion detection and rated them for diagnostic quality using a qualitative scale. After application of the denoising network, the same radiologists evaluated lesion detectability and image quality. For clinical application, a consensus on lesion type and localization on preoperative mammographic examinations of breast cancer patients was reached after discussion. Thereafter, coded low-dose, reconstructed full-dose, and full-dose images were presented and assessed in a random order. Results Lesions on 40% reconstructed full-dose images were better perceived when compared with low-dose images of mastectomy specimens as a reference. In clinical application, as compared to 40% reconstructed images, higher values were given on full-dose images for resolution (p < 0.001); diagnostic quality for calcifications (p < 0.001); and for masses, asymmetry, or architectural distortion (p = 0.037). The 40% reconstructed images showed comparable values to 100% full-dose images for overall quality (p = 0.547), lesion visibility (p = 0.120), and contrast (p = 0.083), without significant differences. Conclusion Effective denoising and image reconstruction processing techniques can enable breast cancer diagnosis with substantial radiation dose reduction.

A study on the rainfall management target considering inter-event time definition (IETD) (무강우 지속시간(IETD)을 고려한 빗물관리 목표량 설정 방안 연구)

  • Baek, Jongseok;Kim, Jaemoon;Park, Jaerock;Lim, Kyoungmo;Shin, Hyunsuk
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.603-611
    • /
    • 2022
  • In urban areas, the impermeable area continues to increase due to urbanization, which interferes with the surface penetrating and infiltrating of rainwater, causing most rainwater runoff to the surface, deepening the distortion of water circulation. Distortion of water circulation affects not only flood disasters caused by rainfall and runoff, but also various aspects such as dry stream phenomenon, deterioration of water quality, and destruction of ecosystem balance, and the Ministry of Environment strongly recommends the use of Low Impact development (LID) techniques. In order to apply the LID technique, it is necessary to set a rainwater management target to handle the increase in outflow after the development of the target site, and the current standard sets the rainwater management target using the 10-year daily rainfall. In this study, the difference from the current standards was analyzed through statistical analysis and classification of independent rainfall ideas using inter-event time definition (IETD) in setting the target amount of rainwater management to improve water circulation. Using 30-year rainfall data from 1991 to 2020, methods such as autocorrelation coefficient (AC) analysis, variation coefficient (VC) analysis, and annual average number of rainfall event (NRE) analysis were applied, and IETD was selected according to the target rainfall period. The more samples the population had, the more IETD tended to increase. In addition, by analyzing the duration and time distribution of independent rainfall according to the IETD, a plan was proposed to calculate the standard design rainfall according to the rainwater management target amount. Therefore, it is expected that it will be possible to set an improved rainwater management target amount if sufficient samples of independent rainfall ideas are used through the selection of IETD as in this study.

Structural and optical properties of Ni-substituted spinel $LiMn_2O_4$ thin films (니켈 치환된 스피넬 LiMn2O4 박막의 구조적, 광학적 성질)

  • Lee, Jung-Han;Kim, Kwang-Joo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.527-533
    • /
    • 2006
  • Spinel $LiNi_xMn_{2-x}O_4$ thin films were synthesized up to x = 0.9 by a sol-gel method employing spin-coating. The Ni-substituted films were found to maintain cubic structure at low x but to exhibit tetragonal structure for $x{\geq}0.6$. Such cubic-tetragonal phase transition indicates that $Ni^{3+}(d7)$ ions with low-spin $(t_{2g}^6,e_g^1)$ state occupy the octahedral sites of the compound, thus being subject to the Jahn-Teller distortion. By x-ray photoelectron spectroscopy both $Ni^{2+}$ and $Ni^{3+}$ ions were detected. Optical properties of the $LiNi_xMn_{2-x}O_4$ films were investigated by spectroscopic ellipsometry (SE) in the visible?ultraviolet range. The measured dielectric function spectra by SE mainly consist of broad absorption structures attributed to charge-transfer (CT) transitions, $O^{2-}(2p){\rightarrow}Mn^{4+}(3d)$ for 1.9 $(t_{2g})$ and $2.8{\sim}3.0$ eV $(e_g)$ structures and $O^{2-}(2p){\rightarrow}Mn^{3+}(3d)$ for 2.3 $(t_{2g})$ and $3.4{\sim}3.6$ eV $(e_g)$ structures. Also, sharp absorption structures were observed at about 1.6, 1.7, and 1.9 eV, interpreted as due to d-d crystal-field transitions within the octahedral $Mn^{3+}$ ion. The strengths of these absorption structures are reduced by the Ni substitution. Rapid reduction of the CT transition strength involving the eg states for x = 0.6 is attributed to the reduced wavefunction overlap between the $e_g$ and the $O^{2-}(2p)$ states due to the tetragonal extension of the lattice constant by the Jahn-Teller effect.

High-resolution computed tomography findings of lung parenchyme changes in very low birth weight infants treated with oxygen (산소 치료를 받은 극소저출생 체중아에서 폐 실질변화에 관한 고해상컴퓨터 단층촬영술 소견에 관한 연구)

  • Jin, Young Man;Chung, David Chanwook;Chang, Young Pyo;Lee, Yung Suk;Lee, En Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Purpose : The objective of this study is to observe high-resolution computed tomography (HRCT) findings of lung parenchyme in very low birth weight (VLBW) infants between the corrected age of 38-42 weeks who were treated with oxygen after birth, and to compare them to the clinical severity of bronchopulmonary dysplasia (BPD). Methods : The lungs of fourty-four VLBW infants with gestational ages of less than 32 weeks and birth weights of less than 1,500 g who were treated with oxygen after birth were examined using HRCT taken when the corrected age was between 38-42 weeks. Common findings among the infants and the frequency of their occurrences were noted. Total CT scores obtained by the summation of air trapping and actelectasis scores and the ratio of bronchus-to-pulmonary artery diameter were used to quantitatively evaluate HRCT findings and correlate them with the clinical severity of BPD as defined by Jobe-Bancalari diagnostic criteria. Results : 1) The most common findings in HRCT images of the lungs were air trapping (56%), atelectasis (70.5%), linear opacity (77%), and distortion of the bronchopulmonary bundle (65.9%). These findings were more commonly observed in infants with BPD in a mixed pattern than those without (P<0.05). However, abnormal findings were also found in HRCT images of some infants without BPD. In infants with BPD, air trapping, atelectasis and total CT scores were higher than those without BPD. Also infants with BPD had a lower bronchus-to-pulmonary artery diameter than those without BPD (P<0.05). 2) The total CT scores (r=0.799, P<0.0001) and the ratio of bronchus-to-pulmonary artery diameter (r=0.576, P<0.0001) showed a linear correlation with the clinical severity of BPD. Conclusion : HRCT findings in VLBW infants between the corrected age of 38-42 weeks who had been treated with oxygen after birth are useful in revealing pathologic changes in the lung parenchyme and show a good correlation with the clinical severity of BPD.

Frame-Layer H.264 Rate Control for Scene-Change Video at Low Bit Rate (저 비트율 장면 전환 영상에 대한 향상된 H.264 프레임 단위 데이터율 제어 알고리즘)

  • Lee, Chang-Hyun;Jung, Yun-Ho;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.127-136
    • /
    • 2007
  • An abrupt scene-change frame is one that is hardly correlated with the previous frames. In that case, because an intra-coded frame has less distortion than an inter-coded one, almost all macroblocks are encoded in intra mode. This breaks up the rate control flow and increases the number of bits used. Since the reference software for H.264 takes no special action for a scene-change frame, several studies have been conducted to solve the problem using the quadratic R-D model. However, since this model is more suitable for inter frames, the existing schemes are unsuitable for computing the QP of the scene-change intra frame. In this paper, an improved rate control scheme accounting for the characteristics of intra coding is proposed for scene-change frames. The proposed scheme was validated using 16 test sequences. The results showed that the proposed scheme performed better than the existing H.264 rate control schemes. The PSNR was improved by an average of 0.4-0.6 dB and a maximum of 1.1-1.6 dB. The PSNR fluctuation was also in proved by an average of 18.6 %.

The Performance Comparison of the MMA and SCA Algorithm for Self Adaptive Equalization (자기 적응 등화를 위한 MMA와 SCA 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.159-165
    • /
    • 2012
  • This paper deals with the performance comparison of adaptive equalization algorithm, MMA and SCA, that is used for the minimization of the distortion and noise effect in the communication channel.. The transmitting signal will be distorted and received due to the nonlinearties of magnitude and phase transfer characteristics of communication channel, the compensation of it by using the self adaptive equalizer. The constant modulus has important metric in the self adaptive equalizer, the MMA uses the 2nd and 4th high order statistics of transmitting signal, the SCA uses the 2nd order statistics of transmitting signal only in order to the calculation of it. We compared to the compensation performance of the MMA and SCA by the computer simulation that are possible to the compensation of the two kinds of transfer characteristics at same times by the relatively simple arithmatic operation. We used to the recovered constellation, residual isi and MSE, SER that are the essential index for the comparison of the adaptive equalizer. The result of performance comparison of algorithms, the MMA which uses the high order statistics of transmitting signal has good performance in the MSE and SER compared to the SCA which is using the low order statistics. But in the recovered costellation and residual isi, the SCA has a good than the MMA.

Feature-based Matching Algorithms for Registration between LiDAR Point Cloud Intensity Data Acquired from MMS and Image Data from UAV (MMS로부터 취득된 LiDAR 점군데이터의 반사강도 영상과 UAV 영상의 정합을 위한 특징점 기반 매칭 기법 연구)

  • Choi, Yoonjo;Farkoushi, Mohammad Gholami;Hong, Seunghwan;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.453-464
    • /
    • 2019
  • Recently, as the demand for 3D geospatial information increases, the importance of rapid and accurate data construction has increased. Although many studies have been conducted to register UAV (Unmanned Aerial Vehicle) imagery based on LiDAR (Light Detection and Ranging) data, which is capable of precise 3D data construction, studies using LiDAR data embedded in MMS (Mobile Mapping System) are insufficient. Therefore, this study compared and analyzed 9 matching algorithms based on feature points for registering reflectance image converted from LiDAR point cloud intensity data acquired from MMS with image data from UAV. Our results indicated that when the SIFT (Scale Invariant Feature Transform) algorithm was applied, it was able to stable secure a high matching accuracy, and it was confirmed that sufficient conjugate points were extracted even in various road environments. For the registration accuracy analysis, the SIFT algorithm was able to secure the accuracy at about 10 pixels except the case when the overlapping area is low and the same pattern is repeated. This is a reasonable result considering that the distortion of the UAV altitude is included at the time of UAV image capturing. Therefore, the results of this study are expected to be used as a basic research for 3D registration of LiDAR point cloud intensity data and UAV imagery.

Comparison of characteristics of silver-grid transparent conductive electrodes for display devices according to fabrication method (제조공법에 따른 디스플레이 소자용 silver-grid 투명전극층의 특성 비교)

  • Choi, Byoung Su;Choi, Seok Hwan;Ryu, Jeong Ho;Cho, Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2017
  • Honeycomb-shaped Ag-grid transparent conductive electrodes (TCEs) were fabricated using two different processes, high density plasma etching and lift-off, and the optical and electrical properties were compared according to the fabrication method. For the fabrication of the Ag-grid TCEs by plasma etching, etch characteristics of the Ag thin film in $10CF_4/5Ar$ inductively coupled plasma (ICP) discharges were studied. The Ag etch rate increased as the power increased at relatively low ICP source power or rf chuck power conditions, and then decreased at higher powers due to either decrease in $Ar^+$ ion energy or $Ar^+$ ion-assisted removal of the reactive F radicals. The Ag-grid TCEs fabricated by the $10CF_4/5Ar$ ICP etching process showed better grid pattern transfer efficiency without any distortion or breakage in the grid pattern and higher optical transmittance values of average 83.3 % (pixel size $30{\mu}m/line$ width $5{\mu}m$) and 71 % (pixel size $26{\mu}m/line$ width $8{\mu}m$) in the visible range of spectrum, respectively. On the other hand, the Ag-grid TCEs fabricated by the lift-off process showed lower sheet resistance values of $2.163{\Omega}/{\square}$ (pixel size $26{\mu}m/line$ width $18{\mu}m$) and $4.932{\Omega}/{\square}$ (pixel size $30{\mu}m/line$ width $5{\mu}m$), respectively.