• Title/Summary/Keyword: Low bypass

Search Result 287, Processing Time 0.026 seconds

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Clinical Study of 80 Cases of Mitral Valve Operations Via Extended Transseptal Approach (확장시킨 경중격 절개방식을 통한 승모판 수술의 80례 임상 분석)

  • 김학제;황재준;최영호;손영상;김욱진;김태식;김현구
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1037-1042
    • /
    • 1998
  • Background: Among the various techniques for the adequate exposure of the mitral valve, the extended transseptal approach is the essential prerequisite for accurate repair or replacement of the mitral apparatus. But the efficacy and safty of the extended transseptal approach has not determined in Korea yet. Materials and methods: Retrospective data of 80 consecutive patients, operated from September 1992 to July 1997 were reviewed. Seventy- eight patients underwent mitral valve replacement and 2 patients underwent excision of left atrial myxoma. Thirty-eight of 78 patients had other concomitant procedures such as aortic valve replacement(n=22), tricuspid annulopasty(n=14), coronary artery bypass graft(n=1) and closure of ventricular septal defect(n=1). Mean follow up was 23.3±15.0 months and total follow up was 1792 patient-months. Results: The hospital mortality rate was 3.8%(3 patients). Two deaths were due to low cardiac output and one due to postoperative bleeding of coagulopathy. Among the 46 patients who had atrial fibrillation preoperatively, 45 had atrial fibrillation postoperatively and 1 converted to sinus rhythm. All 34 patients who were in normal sinus rhythm preoperatively remained in sinus rhythm after the operation. Mean aortic cross clamping time was 62 minutes for isolated mitral procedure and 90 minutes for concomitant procedures. There were no specific complications related to this approach. Conclusions: We suggest that the extended transseptal approach is an easy and good method for mitral valve surgery, especially in patients with small sized left atrium.

  • PDF

Dual Grafting of Left Internal Thoracic Artery and Saphenous Vein to Left Anterior Descending Artery (좌내흉동맥편과 복재정맥편을 좌전하행지에 동시에 문합한 관상동맥 우회로술의 임상적 결과)

  • 최종범;양현웅;한재오;최순호
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.709-714
    • /
    • 1999
  • Background: When internal thoracic artery (ITA) and saphenous vein graft are anastomosed to the same coronary artery, the patency rate of the internal thoracic artery graft with relatively narrow diameter may be decreased owing to competition of pressure and flow rate. We evaluate the clinical outcome and the patency of the ITA graft in patients undergoing dual grafting to the same coronary artery. Material and Method: In 14 patients with the ITA graft having relatively low flow, the ITA and saphenous vein graft were anastomosed to the same coronary artery. During the mean follow-up period of 33.5 months, coronary angiography was performed in 6 patients who complained of recurrent angina, needed confirmation of graft flow, or showed postoperative Q wave. Result: In all 6 patients, the ITA and saphenous vein grafts were patent without stenosis or obstruction. Two patients showed good flow in both grafts, 2 showed competitive flow in the ITA graft, and the remaining 2 showed poor flow in the ITA graft. Conclusion: Early operative closure When saphenous vein grafting was added to the same coronary artery that the internal thoracic artery was anastomosed to, the perfusion to the coronary artery was satisfied and the dual grafting did not affect the short-term and mid-term patency rate of the ITA.

  • PDF

Early Outcomes of Sutureless Aortic Valves

  • Hanedan, Muhammet Onur;Mataraci, Ilker;Yuruk, Mehmet Ali;Ozer, Tanil;Sayar, Ufuk;Arslan, Ali Kemal;Ziyrek, Ugur;Yucel, Murat
    • Journal of Chest Surgery
    • /
    • v.49 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was $71.15{\pm}8.60years$. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was $56.9{\pm}9.93$. The CPB time was $96.51{\pm}41.27minutes$ and the cross-clamping time was $60.85{\pm}27.08minutes$. The intubation time was $8.95{\pm}4.19hours$, and the intensive care unit and hospital stays were $2.89{\pm}1.42days$ and $7.86{\pm}1.42days$, respectively. The mean quantity of drainage from chest tubes was $407.69{\pm}149.28mL$. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was $687.24{\pm}24.76days$. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation

  • Ahn, Chi Bum;Kang, Yang Jun;Kim, Myoung Gon;Yang, Sung;Lim, Choon Hak;Son, Ho Sung;Kim, Ji Sung;Lee, So Young;Son, Kuk Hui;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.49 no.3
    • /
    • pp.145-150
    • /
    • 2016
  • Background: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation. Methods: Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement. To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous $O_2$ saturation, and lactate were measured. Results: The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used. Conclusion: After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow.

Study on Variable Systems for Compressor and Turbine and its Control Scheme (압축기 정익, 터빈 노즐 가변 메카니즘 및 제어기법 연구)

  • Kim, Sangjo;Kim, Donghyun;Bae, Kyoungwook;Kim, Dae-il;Son, Changmin;Kim, Kuisoon;Lee, Daewoo;Go, Jeungsang;Choi, Dong-Whan;Kim, Myungho;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.1-14
    • /
    • 2015
  • In case of a gas turbine engine for supersonic operation, the engine have a wide range of operating inlet mass flow rate and required high performance such as thrust and fuel consumption. Therefore, variable system and its optimal control logic are essentially needed. In this work, a method for performance prediction of a gas turbine engine with variable system compressor and its control scheme were developed. Conceptual design of compact acuation system for the operation of the variable system was also conducted. The performance of a low-bypass ratio mixed flow turbofan engine was analyzed, and it was observed that the surge margin of the engine is improved at off-design condition by applying the control scheme.

A Multiphase DLL Based on a Mixed VCO/VCDL for Input Phase Noise Suppression and Duty-Cycle Correction of Multiple Frequencies (입력 위상 잡음 억제 및 체배 주파수의 듀티 사이클 보정을 위한 VCO/VCDL 혼용 기반의 다중위상 동기회로)

  • Ha, Jong-Chan;Wee, Jae-Kyung;Lee, Pil-Soo;Jung, Won-Young;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.11
    • /
    • pp.13-22
    • /
    • 2010
  • This paper proposed the dual-loops multiphase DLL based mixed VCO/VCDL for a high frequency phase noise suppression of the input clock and the multiple frequencies generation with a precise duty cycle. In the proposed architecture, the dual-loops DLL uses the dual input differential buffer based nMOS source-coupled pairs at the input stage of the mixed VCO/VCDL. This can easily convert the input and output phase transfer of the conventional DLL with bypass pass filter characteristic to the input and output phase transfer of PLL with low pass filter characteristic for the high frequency input phase noise suppression. Also, the proposed DLL can correct the duty-cycle error of multiple frequencies by using only the duty-cycle correction circuits and the phase tracking loop without additional correction controlled loop. At the simulation result with $0.18{\mu}m$ CMOS technology, the output phase noise of the proposed DLL is improved under -13dB for 1GHz input clock with 800MHz input phase noise. Also, at 1GHz operating frequency with 40%~60% duty-cycle error, the duty-cycle error of the multiple frequencies is corrected under $50{\pm}1%$ at 2GHz the input clock.

Control Algorithm Characteristic Study of Cooling System for Automotive Fuel Cell Application. (차량용 연료전지 냉각시스템 제어 알고리즘 특성 연구)

  • Han, Jae Young;Park, Ji Soo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • Thermal management of a fuel cell is important to satisfy the requirements of durability and efficiency under varying load conditions. In this study, a linear state feedback controller was designed to maintain the temperature within operating conditions. Due to the nonlinearity of automotive fuel cell system, the state feedback controller results in marginal stable under load condition from $0.5A/cm^2$ to $0.7A/cm^2$. A PWM (Pulse Width Modulation) and the modified state feedback controller are applied to control the temperature under the load condition from $0.5A/cm^2$ to $0.7A/cm^2$. The cooling system model is composed of a reservoir, radiator, bypass valve, fan, and a water pump. The performance of the control algorithm was evaluated in terms of the integral time weighted absolute error (ITAE). Additionally, MATLAB/SIMULINK$^{(R)}$ was used for the development of the system models and controllers. The modified state feedback controller was found to be more effective for controlling temperature than other algorithms when tested under low load conditions.

Hydrogeochemical study of a watershed in Pocheon area: controls of water chemistry

  • Kim, Kyoung-Ho;Yun, Seong-Taek;Chae, Soo-Ho;Jean, Jong-Wook;Lee, Jeong-Ho;Kweon, Hae-Woo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.121-121
    • /
    • 2004
  • The groundwater in the Pocheon area occurs from both a fractured bedrock aquifer in igneous and metamorphic rocks and an alluvial aquifer with a thickness of <50 m, and forms a major source of domestic and agricultural water supply. In this study, we performed a hydrogeochemical study in order to identify the control of geochemical processes on groundwater quality. For this study, groundwater level and physicochemical parameters (EC, Eh, pH, alkalinity) were monitored once a month from a total of 150 groundwater wells between June 2003 to August 2004. A total of 153 water samples (13 surface water, 66 alluvial groundwater, 74 bedrock groundwater) were also collected and analyzed in February 2004. Groundwater chemistry in the study area is very complex, depending on a number of major factors such as geology, degree of chemical weathering, and quality of recharge water. Hydrochemical reactions such as the leaching of surficial and near-solace soil salts, dissolution of calcite, cation exchange, and weathering of silicate minerals are proposed to explain the chemistry of natural groundwater. Alluvial groundwaters locally have very high TDS concentrations, which are characterized by their chloride(nitrate)-sulfate-bicabonate facies and low Na/Cl ratio. Their grondwater levels are highly fluctuated according to rainfall event. We suggest that high nitrate content and salinity in such alluvial groundwaters originates from the local recharge of sewage effluents and/or fertilizers. Likewise, high concentrations of nitrate were also locally observed in some bedrock groundwaters, suggesting their effect of anthropogenic contamination. This is possibly due to the bypass flow taking place through macropores. Tile degree of the weathering of silicate minerals seems to be a major control of the distribution of major cations (sodium, calcium, magnesium, potassium) in bedrock groundwaters, which show a general increase with increasing depth of wells. Thermodynamic interpretation of groundwater chemistry shows that the groundwater in the study area is in chemical equilibrium with kaolinite and Na-montmorillonite, which indicates that weathering of plagioclase to those minerals is a major control of hydrochemistry of bedrock groundwater. The interpretation of the molar ratios among major ions, as well as the mass balance calculation, also indicates the role of both dissolution/precipitation of calcite and Ca-Na cationic exchange as bedrock groundwaters evolves progressively.

  • PDF