• Title/Summary/Keyword: Low beam

Search Result 1,839, Processing Time 0.027 seconds

Effect of Kinetic Parameters on Simultaneous Ramp Reactivity Insertion Plus Beam Tube Flooding Accident in a Typical Low Enriched U3Si2-Al Fuel-Based Material Testing Reactor-Type Research Reactor

  • Nasir, Rubina;Mirza, Sikander M.;Mirza, Nasir M.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.700-709
    • /
    • 2017
  • This work looks at the effect of changes in kinetic parameters on simultaneous reactivity insertions and beam tube flooding in a typical material testing reactor-type research reactor with low enriched high density ($U_3Si_2-Al$) fuel. Using a modified PARET code, various ramp reactivity insertions (from $0.1/0.5 s to $1.3/0.5 s) plus beam tube flooding ($0.5/0.25 s) accidents under uncontrolled conditions were analyzed to find their effects on peak power, net reactivity, and temperature. Then, the effects of changes in kinetic parameters including the Doppler coefficient, prompt neutron lifetime, and delayed neutron fractions on simultaneous reactivity insertion and beam tube flooding accidents were analyzed. Results show that the power peak values are significantly sensitive to the Doppler coefficient of the system in coupled accidents. The material testing reactor-type system under such a coupled accident is not very sensitive to changes in the prompt neutron life time; the core under such a coupled transient is not very sensitive to changes in the effective delayed neutron fraction.

Investigation of LC Alignment Using Ion-beam and Overcoat Layer (이온빔 에너지와 유기절연막 사용에 의한 액정 배향 연구)

  • Kim, Byoung-Yong;Park, Hong-Gyu;Lee, Kang-Min;Oh, Byeong-Yun;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Kim, Jong-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.370-370
    • /
    • 2007
  • The liquid crystal (LC) aligning capabilities treated on the Organic overcoat thin film surfaces by ion beam irradiation and rubbing method was successfully studied for the first time. The Organic overcoat layer was coated by spin-coating. In order to characterize the LC alignment, the microscope, pretilt angle, thermal stress, and atomic force microscopy (AFM) image was used. The good LC aligning capabilities treated on the Organic overcoat thin film surfaces with ion beam exposure of $45^{\circ}$ above ion beam energy density of 1200 eV can be achieved. But, the alignment of defect of NLC on the Organicovercoat surface at low energy density of 600 eV was measured. The pretilt angle of NLC on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min at energy density of 1800eV was measured about 1.13 degree. But, low pretilt angles of NLC on the Organic overcoat thin film surface with ion beam exposure at energy density of 600, 1200, 2400, and 3000 eV was measured. Also, the pretilt angle of NLC on the rubbed Organic overcoat thin film surfaces was measured about 0.04 degrees. Finally, the good thermal stability of LC alignment on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min can be measured.

  • PDF

Ultrasonic Examination of Thick Austenitic Stainless Steel Welds and Factors Influence the Sensitivity

  • Palaniappan, M.;Subbaratnam, R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.372-379
    • /
    • 2003
  • The problems encountered by ultrasonic testing of austenitic stainless steel weld joints are discussed in the paper. Due to low thermal conductivity and the occurrence of single phase between the melting point and the room temperature, coarse and oriented grains are formed in such weld metals more in thick sections. This leads to higher scattering at the grain boundaries and low signal to noise ratio, and extensive beam skewing. Experimental results to understand these problem are explained.

Changes of SDS-PAGE Pattern of Pork Myofibrillar Proteins Induced by Electron Beam Irradiation

  • Whang Key;Jeong, Dong-Kwan;Kim, Hyuk-Il
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.4
    • /
    • pp.378-381
    • /
    • 2005
  • Actin and myosin solutions and fresh ground pork were irradiated with the electron beam (e-beam) at a dose of 0, 1.5, 3.0, 5.0 and 10 kGy. The changes in SDS-PAGE pattern of 2 proteins and the salt-soluble proteins extracted from ground pork after e-beam irradiation were monitored. When the myosin solution was irradiated with e-beam, myosin was degraded completely. Complete myosin degradations were observed even with the lowest dose (1.5 kGy) of e-beam treatment. Actin was degraded with the irradiation, but to a less extent than myosin was. The degradation of actin increased as the e-beam treatment increased from 1.5 to 10.0 kGy. Among the salt-soluble proteins extracted from ground pork, myosin was degraded gradually when the e-beam dose increased from 1.5 up to 10.0 kGy. Similar gradual increase in the degradation of actin also occurred with the increase of irradiation. Increases of 2 low molecular weight compounds (<29 kDa) were observed when the irradiation dose increased from 1.5 to 10.0 kGy. These 2 molecules are thought to be the breakdown products produced from the degradation of major salt-soluble proteins, myosin and actin. The salt-soluble protein content of ground pork did not change with the e-beam irradiation.

Transient thermo-mechanical response of a functionally graded beam under the effect of a moving heat source

  • Al-Huniti, Naser S.;Alahmad, Sami T.
    • Advances in materials Research
    • /
    • v.6 no.1
    • /
    • pp.27-43
    • /
    • 2017
  • The transient thermo-mechanical behavior of a simply-supported beam made of a functionally graded material (FGM) under the effect of a moving heat source is investigated. The FGM consists of a ceramic part (on the top), which is the hot side of the beam as the heat source motion takes place along this side, and a metal part (in the bottom), which is considered the cold side. Grading is in the transverse direction, with the properties being temperature-dependent. The main steps of the thermo-elastic modeling included deriving the partial differential equations for the temperatures and deflections in time and space, transforming them into ordinary differential equations using Laplace transformation, and finally using the inverse Laplace transformation to find the solutions. The effects of different parameters on the thermo-mechanical behavior of the beam are investigated, such as the convection coefficient and the heat source intensity and speed. The results show that temperatures, and hence the deflections and stresses increase with less heat convection from the beam surface, higher heat source intensity and low speeds.

Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography (전자빔 가공기의 진공제어 밸브설계 및 특성평가)

  • Lee Chan-Hong;Lee Hu-Sang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

Development and Evaluation of an Electron Beam Source for Microscopy and Its Applications

  • Ahn, Seung-Joon;Oh, Tae-Sik;Kim, Ho-Seob;Ahn, Seong-Joon
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.127-130
    • /
    • 2010
  • We have developed an efficient electron beam (e-beam) source, a microcolumn, that can be used as a source module for of microscopy and its applications. To obtain a low operating voltage, a very sharp cold field electron emitter was developed by electrochemically etching a tungsten wire. Laser diffraction was used for the fabrication of high-quality electron lenses and for their precise alignment. The measurement of the e-beam currents, and SEM images captured by the microcolumn confirmed the potential of the device as a very good e-beam source.

Evaluation of an applicability of lattice girders for the tunnel support (터널지보재로서 격자지보(Lattice Girder)의 현장적용성 평가 연구)

  • 문홍득;이성원;배규진
    • Tunnel and Underground Space
    • /
    • v.6 no.2
    • /
    • pp.122-130
    • /
    • 1996
  • Generally the NATM technique uses shotcrete, rock bolts, H-beam steel ribs, and concrete lining for the tunnel support in Korea. Among them, H-beam steel ribs are extremely heavy and difficult for workers to handle. Therefore, especially in Europe, lattice girders are being used instead of H-beam steel ribs for tunnel support. Lattice girders have basically the same function as H-beam steel ribs in tunnelling. The main advantages of using lattice girders compared to H-beam steel rib supports are as follows: 1) lattice girders have relatively a low weight enough to be easily lifted and installed by labors and 2) they create a more effective bond with the shotcrete. The purpose of this study is to evaluate the effectiveness and applicability of lattice girders compared to H-beam steel ribs used in construction tunnel sites and to show that lattice girders can be adequately applied in domestic tunnel construction sites as a new tunnel support system.

  • PDF

Heat Treatment Using a Laser Beam or an Electron Beam (레이저 및 전자빔을 이용한 표면 열처리)

  • 김홍준;최우천;권영각
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.427-432
    • /
    • 1995
  • Surface heat treatment using a laser beam or an electron beam is studied through numerical analyses and experiments. For the surface heat treatment process, a theoretical model is developed to predict the effects of laser beam power, travel speed and properties of a workpiece on the depth and width of the heat affected zone(HAZ). The shape of HAZ and the hardness of heat-treated surface are experimentally obtained using an electron beam. Three materials(SS41, S45C and S55C) are selected as workpiece materials. The hardness of HAZ is increased up to 3 times for materials of a low carbon content. The results of the numerical analysis are compared with those of experiments. The comparison shows that the numerical model predicts larger depths and widths.

The Control of Flexible Beam using Nonlinear Compensator with Dual-Input Describing Function (쌍입력 기술함수를 갖는 비선형 보상기를 이용한 유연한 빔의 제어)

  • 권세현;이형기;최부귀
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.5
    • /
    • pp.644-650
    • /
    • 1998
  • In this paper , a state space model for flexible beam is presented using the assumed-modes approach. The state space equation is derived for a flexible beam in which one end is connected to a motor and is driven by a torque equation and the other end is free. Many of the transfer function proposed thus far use the torque to the flexible beam as the input and the tip deflection of the flexible beam as the output. The Technique for the analysis and synthesis of the dual-input describing function(DIDF) is introduced here and the construction of a non-linear compensator, based on this technique, is proposed. This non-linear compensator, properly connected in the direct path of a closed-loop linear or non-linear control system. The above non-linear network is used to compensate linear and non-linear systems for instability, limit cycles, low speed of response and static accuracy. The effectiveness of the proposed scheme is demonstrated through computer simulation and experimental results.

  • PDF