• Title/Summary/Keyword: Low beam

Search Result 1,846, Processing Time 0.027 seconds

Experimental study of buckling-restrained brace with longitudinally profiled steel core

  • Lu, Junkai;Ding, Yong;Wu, Bin;Li, Yingying;Zhang, Jiaxin
    • Structural Engineering and Mechanics
    • /
    • v.81 no.6
    • /
    • pp.715-728
    • /
    • 2022
  • A new type of buckling-restrained braces (BRBs) with a longitudinally profiled steel plate working as the core (LPBRB) is proposed and experimentally investigated. Different from conventional BRBs with a constant thickness core, both stiffness and strength of the longitudinally profiled steel core along its longitudinal direction can change through itself variable thickness, thus the construction of LPBRB saves material and reduces the processing cost. Four full-scale component tests were conducted under quasi-static cyclic loading to evaluate the seismic performance of LPBRB. Three stiffening methods were used to improve the fatigue performance of LPBRBs, which were bolt-assembled T-shaped stiffening ribs, partly-welded stiffening ribs and stiffening segment without rib. The experimental results showed LPBRB specimens displayed stable hysteretic behavior and satisfactory seismic property. There was no instability or rupture until the axial ductility ratio achieved 11.0. Failure modes included the out-of-plane buckling of the stiffening part outside the restraining member and core plate fatigue fracture around the longitudinally profiled segment. The effect of the stiffening methods on the fatigue performance is discussed. The critical buckling load of longitudinally profiled segment is derived using Euler theory. The local bulging behavior of the outer steel tube is analyzed with an equivalent beam model. The design recommendations for LPBRB are presented finally.

X-Ray Diffraction Analysis of Various Calcium Silicate-Based Materials

  • An, So-Youn;Lee, Myung-Jin;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.22 no.3
    • /
    • pp.191-198
    • /
    • 2022
  • Background: The purpose of this study was to evaluate the composition of the crystal phases of various calcium silicate-based materials (CSMs): ProRoot white MTA (mineral trioxide aggregate) (WMTA), Ortho MTA (OM), Endocem MTA (EM), Retro MTA (RM), Endocem Zr (EN-Z), BiodentineTM (BD), EZ-sealTM (EZ), and OrthoMTA III (OM3). Methods: In a sample holder, 5 g of the powder sample was placed and the top surface of the material was packed flat using a sterilized glass slide. The prepared slides were mounted on an X-ray diffraction (XRD) instrument (D8 Advance; Bruker AXS GmbH, Germany). The X-ray beam 2θ angle range was set at 10~90° and scanned at 1.2° per minute. The Cu X-ray source set to operate at 40 kV and 40 mA in the continuous mode. The peaks in the diffraction pattern of each sample were analyzed using the software Diffrac (version 2.1). Then, the peaks were compared and matched with those of standard materials in the corresponding Powder Diffraction File (PDF-2, JCPDS International Center for Diffraction Data). A powder samples of the materials were analyzed using XRD and the peaks in diffraction pattern were compared to the Powder Diffraction File data. Results: Eight CSMs showed a similar diffraction pattern because their main component was calcium silicate. Eight CSMs showed similar diffraction peaks because calcium silicate was their main component. Two components were observed to have been added as radiopacifiers: bismuth oxide was detected in WMTA, OM, and EM while zirconium oxide was detected in RM, EN-Z, BD, EZ, and OM3. Unusual patterns were detected for the new material, OM3, which had strong peaks at low angles. Conclusion: It was caused by the presence of Brushite, which is believed to have resulted in crystal growth in a particular direction for a specific purpose.

Effect of Load Velocity on Seismic Performance of Steel Beam-column Connection (하중속도가 강구조 보-기둥 접합부 내진성능에 미치는 영향)

  • Lee, Ki-Won;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.182-192
    • /
    • 2022
  • Brittle feature is one of the fracture behaviors of structure s and has a great influence on the seismic performance of structure materials. The load velocity acts as one of the main causes of brittle fracture, and in particular, in situations such as earthquakes, a high load velocity acts on buildings. However, most of the seismic performance evaluation of the domestic and external steel connections is conducted through static experiments. Therefore, there is a possibility that brittle fracture due to factors such as degradation of material toughness and reduction of maximum deformation rate due to high load velocity during an earthquake was not sufficiently considered in the existing seismic performance evaluation. This study conducts a static test at a low load velocity according to the existing experimental method and a dynamic test at a high load velocity using a shaking table, respectively. It compares and analyzes the fracture shape and structural performance according to the results of each experiment, and finally analyzes the effect of the load velocity size on the seismic performance of the connection.

Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method

  • Nabil M. Mansour;Mohamed E. Abdelshaheed;Ahmed H. El-Sabbagh;Ahmed M. Bahaa El-Din;Young Chul Kim;Jong-Woo Choi
    • Archives of Plastic Surgery
    • /
    • v.50 no.3
    • /
    • pp.254-263
    • /
    • 2023
  • Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations: 0.18 mm; mean angular variations: 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.

Analysis of the Influence of Atmospheric Turbulence on the Ground Calibration of a Star Sensor

  • Xian Ren;Lingyun Wang;Guangxi Li;Bo Cui
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • Under the influence of atmospheric turbulence, a star's point image will shake back and forth erratically, and after exposure the originally small star point will spread into a huge spot, which will affect the ground calibration of the star sensor. To analyze the impact of atmospheric turbulence on the positioning accuracy of the star's center of mass, this paper simulates the atmospheric turbulence phase screen using a method based on a sparse spectrum. It is added to the static-star-simulation device to study the transmission characteristics of atmospheric turbulence in star-point simulation, and to analyze the changes in star points under different atmospheric refractive-index structural constants. The simulation results show that the structure function of the atmospheric turbulence phase screen simulated by the sparse spectral method has an average error of 6.8% compared to the theoretical value, while the classical Fourier-transform method can have an error of up to 23% at low frequencies. By including a simulation in which the phase screen would cause errors in the center-of-mass position of the star point, 100 consecutive images are selected and the average drift variance is obtained for each turbulence scenario; The stronger the turbulence, the larger the drift variance. This study can provide a basis for subsequent improvement of the ground-calibration accuracy of a star sensitizer, and for analyzing and evaluating the effect of atmospheric turbulence on the beam.

Characteristics of impacted mandibular third molar-related lesions

  • Dong-Min Lee;Jihye Ryu;Hyeonjin Kim;Jae-Yeol Lee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.3
    • /
    • pp.153-160
    • /
    • 2024
  • Objectives: This study identifies factors for differential diagnosis among lesions by retrospectively comparing panoramic and cone-beam computed tomography images and analyzing the characteristics of lesions associated with impacted mandibular third molars (IMTs). Materials and Methods: A retrospective cohort study was conducted in patients who simultaneously underwent IMT extraction surgery and related benign tumor resection or cyst enucleation at our institution from 2017 to 2021. To compare the characteristics of each group, two comparative analyses were conducted. The first comparison considered the most frequently observed lesions associated with IMTs: dentigerous cysts, odontogenic keratocysts (OKCs), and ameloblastoma. The second comparison involved placing dentigerous cysts, which have a relatively low recurrence rate, into group A and placing OKC, ameloblastoma, and odontogenic myxoma, which have high recurrence rates, into group B. Results: Significant differences in the size of the lesion were found in the order of ameloblastoma, OKC, and dentigerous cyst (P<0.05). The buccolingual width of ameloblastoma differed significantly from that of the other groups, with no significant difference observed between the OKCs and dentigerous cysts (P=0.083). Conclusion: Patient age and lesion size differed significantly among lesion types associated with IMTs, with younger age and larger lesions for OKCs and odontogenic tumors. OKCs are likely to have a larger mesiodistal width than dentigerous cysts. The buccolingual width of ameloblastomas was larger than those of dentigerous cysts and OKCs.

Comparison of the seismic performance of Reinforced Concrete-Steel (RCS) frames with steel and reinforced concrete moment frames in low, mid, and high-rise structures

  • Jalal Ghezeljeh;Seyed Rasoul Mirghaderi;Sina Kavei
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.249-263
    • /
    • 2024
  • This article presents a comparative analysis of seismic behavior in steel-beam reinforced concrete column (RCS) frames versus steel and reinforced concrete frames. The study evaluates the seismic response and collapse behavior of RCS frames of varying heights through nonlinear modeling. RCS, steel, and reinforced concrete special moment frames are considered in three height categories: 5, 10, and 20 stories. Two-dimensional frames are extracted from the three-dimensional structures, and nonlinear static analyses are conducted in the OpenSEES software to evaluate seismic response in post-yield regions. Incremental dynamic analysis is then performed on models, and collapse conditions are compared using fragility curves. Research findings indicate that the seismic intensity index in steel frames is 1.35 times greater than in RCS frames and 1.14 times greater than in reinforced concrete frames. As the number of stories increases, RCS frames exhibit more favorable collapse behavior compared to reinforced concrete frames. RCS frames demonstrate stable behavior and maintain capacity at high displacement levels, with uniform drift curves and lower damage levels compared to steel and reinforced concrete frames. Steel frames show superior strength and ductility, particularly in taller structures. RCS frames outperform reinforced concrete frames, displaying improved collapse behavior and higher capacity. Incremental Dynamic Analysis results confirm satisfactory collapse capacity for RCS frames. Steel frames collapse at higher intensity levels but perform better overall. RCS frames have a higher collapse capacity than reinforced concrete frames. Fragility curves show a lower likelihood of collapse for steel structures, while RCS frames perform better with an increase in the number of stories.

Impact of dental imaging on pregnant women and recommendations for fetal radiation safety: A systematic review

  • Thiago Oliveira Gamba;Fernanda Visioli;Deise Renata Bringmann;Pantelis Varvaki Rados;Heraldo Luis Dias da Silveira;Isadora Luana Flores
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: This study was conducted to investigate the safety of dental imaging in pregnant women with respect to fetal health. Materials and Methods: Searches were conducted of the PubMed, Scopus, and Web of Science databases in May 2023. The inclusion criteria encompassed cross-sectional and longitudinal studies that focused on the analysis of diagnostic dental imaging in pregnant women, as well as studies utilizing phantoms to simulate imaging examinations. The exclusion criteria consisted of reviews, letters to the editor, book chapters, and abstracts from scientific conferences and seminars. Results: A total of 3,913 articles were identified. Based on a review of the titles and abstracts, 3,892 articles were excluded, leaving 21 articles remaining for full-text review. Of these, 18 were excluded, and 4 additional articles were included as cross-references. Ultimately, 7 articles underwent quantitative-qualitative analysis. Three retrospective studies were focused on pregnant women who underwent dental imaging procedures. The remaining 4 studies utilized female phantoms to simulate imaging examinations and represent the radiation doses absorbed by the uterus or thyroid. Conclusion: Few dental radiology studies have been conducted to determine the safe radiation threshold for pregnant women. Additionally, the reviewed articles did not provide numbers of dental examinations, by type, corresponding to this dose. Dental imaging examinations of pregnant women should not be restricted if clinically indicated. Ultimately, practitioners must be able to justify the examination and should adhere to the "as low as diagnostically acceptable, being indication-oriented and patient-specific" (ALADAIP) principle of radioprotection.

The Study of Dose Change by Field Effect on Atomic Number of Shielding Materals in 6 MeV Electron Beam (6 MeV 전자선의 차폐물질 원자번호와 조사야 크기에 따른 선량변화 연구)

  • Lee, Seung Hoon;Kwak, Keun Tak;Park, Ju Kyeong;Gim, Yang Soo;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: In this study, we analyzed how the dose change by field size effects on atomic number of shielding materials while using 6 MeV election beam. Materials and Methods: The parallel plate chamber is mounted in $25{\times}25cm^2$ the phantom such that the entrance window of the detector is flush with the phantom surface. phantom was covered laterally with aluminum, copper and lead which thickness have 5% of allowable transmission and then the doses were measured in field size $6{\times}6$, $10{\times}10$ and $20{\times}20cm^2$ respectively. 100 cGy was irradiated using 6 MeV electron beam and SSD (Source Surface Distance) was 100 cm with $10{\times}10cm^2$ field size. To calculate the photon flux, electron flux and Energy deposition produced after pass materals respectively, MCNPX code was used. Results: The results according to the various shielding materials which have 5% of allowable transmission are as in the following. Thickness change rate with field size of $6{\times}6cm^2$ and $20{\times}20cm^2$ that compared to the field size of $10{\times}10cm^2$ found to be +0.06% and -0.06% with aluminum, +0.13% and -0.1% with copper, -1.53% and +1.92% with lead respectively. Compare to the field size $10{\times}10cm^2$, energy deposition for $6{\times}6cm^2$ and $20{\times}20cm^2$ had -4.3% and +4.85% respectively without shielding material. With aluminum it had -0.87% and +6.93% respectively and with lead it had -4.16% and +5.57% respectively. When it comes to photon flux with $6{\times}6cm^2$ and $20{\times}20cm^2$ of field sizes the chance -8.95% and +15.92% without shielding material respectively, with aluminum the number -15.56% and +16.06% respectively and with copper the chance -12.27% and +15.53% respectively, with lead the number +12.36% and -19.81% respectively. In case of electron flux in the same condition, the number -3.92% and +4.55% respectively without shielding material respectively, with aluminum the number +0.59% and +6.87% respectively, with copper the number -1.59% and +3.86% respectively, with lead the chance -5.15% and +4.00% respectively. Conclusion: In this study, we found that the required thickness of the shielding materials got thinner with low atomic number substance as the irradiation field is increasing. On the other hand, with high atomic number substance the required thickness had increased. In addition, bremsstrahlung radiation have an influence on low atomic number materials and high atomic number materials are effected by scattered electrons.

  • PDF

The Results and Prognostic Factors of Postoperative Radiation Therapy in the Early Stages of Endometrial Cancer (초기 자궁내막암의 수술 후 방사선치료의 결과와 예후인자)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.149-159
    • /
    • 2008
  • Purpose: To evaluate the results and prognostic factors for postoperative adjuvant radiation therapy in patients at stages I and II of endometrial cancer. Materials and Methods: Between January 1991 and December 2006, 35 patients with FIGO stages I and II disease, who received adjuvant radiation therapy following surgery for endometrial cancer at Ewha Womans University Hospital, were enrolled in this study. A total of 17 patients received postoperative pelvic external beam radiation therapy; whereas, 12 patients received vaginal brachytherapy alone, and 6 patients received both pelvic radiation therapy and vaginal brachytherapy. Results: The median follow-up period for all patients was 54 months. The 5-yr overall survival and disease-free survival rates for all patients were 91.4% and 81.7%, respectively. The 5-yr overall survival rates for low-risk, intermediate-risk, and high-risk groups were 100%, 100% and 55.6%, respectively. In addition, the 5-yr disease-free survival rates were 100%, 70.0%, and 45.7%, respectively. Although no locoregional relapses were identified, distant metastases were observed in 5 patients (14%). The most common site of distant metastases was the lung, followed by bone, liver, adrenal gland, and peritoneum. A univariate analysis revealed a significant correlation between distant metastases and risk-group (p=0.018), pathology type (p=0.001), and grade (p=0.019). A multivariate analysis also revealed that distant metastases were correlated with pathology type (p=0.009). Papillary, serous and clear cell carcinoma cases demonstrated a poor patient survival rate compared to cases of endometrioid adenocarcinoma or adenosquamous carcinoma. The most common complication of pelvic external beam radiation therapy was enteritis (30%), followed by proctitis, leucopenia, and lymphedema. All these complications were of RTOG grades 1 and 2; no grades 3 and 4 were observed. Conclusion: For the low-risk and intermediate-risk groups (stages 1 and 2) endometrial cancer, pelvic control, and overall survival rate was free of severe toxicity when pelvic radiation therapy or vaginal brachytherapy was performed. In the high-risk group, pelvic control rate was excellent, but the survival rate was poor due to distant metastases, in spite of the pelvic radiation therapy. The combined modality of chemotherapy and radiation therapy is recommended for high-risk groups. For the intermediate-risk group, a prospective randomized study is required to compare the efficacy between whole pelvic radiation therapy and vaginal brachytherapy.