• Title/Summary/Keyword: Low attenuation area

Search Result 52, Processing Time 0.024 seconds

Site Attenuations of an Open Area Test Site (야회시험장의 시험장감쇠량)

  • 김기채;정연춘;정정환;정낙삼
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1336-1343
    • /
    • 1990
  • In this paper the theoretical analysis of the site attenuation was made on the concept of mutual impedance of antennas and the cause of characteristic hump in the site attenuation curve below 80 MHz is explained. The deviation between the FCC site attenuatios and the experimental results of an ideal open area test site at low frequencies(below 80MHz) was found to be the mutual coupling effects of the antennas under the FCC's measurement conditions. It seems desirable that the site attenuations curve of FCC document be revicused to the theoretical curves presented in this paper is long as the FCC's measurement conditions are to the applied.

  • PDF

Hypereosinophilic Syndrome: CT Findings in Patients with Hepatic Lobar or Segmental Involvement

  • Jae Hoon Lim;Won Jae Lee;Dong Ho Lee;Kyung Jin Nam
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.98-103
    • /
    • 2000
  • Objective: The purpose of this study was to describe the CT findings of hepatic hypereosinophilic syndrome in which hepatic lobes or segments were involved. Materials and Methods: Seven patients with hypereosinophilic syndrome with hepatic lobar or segmental involvement were included in our study. In all seven, diagnosis was based on liver biopsy and the results of corticosteroid treatment. CT findings were retrospectively reviewed by three radiologists, who reached a consensus. Biopsy specimens were examined, with special reference to portal and periportal inflammation. Results: CT demonstrated well-defined, homogeneous or heterogeneous low attenuation with a straight margin limited to a hepatic lobe (n = 2), segments (n = 3), or subsegments (n = 2), particularly during the portal phase. Where there was subsegmental involvement, lesions were multiple, ovoid or wedge-shaped, and showed low attenuation. In two patients with lobar or segmental involvement, segmental portal vein narrowing was observed. Histopathologic examination disclosed eosinophilic infiltration in the periportal area, sinusoids and central veins, as well as portal phlebitis. Conclusion: Hypereosinophilic syndrome may involve the presence of hepatic lobar, segmental, or subsegmental low-attenuated lesions, as seen on CT images. Their presence may be related to damage of the liver parenchyma and to portal phlebitis.

  • PDF

Noise Attenuation Effects of Trees (수목의 소음감쇄효과)

  • Kim, Seong-Il;Oh, Dong Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.400-409
    • /
    • 1994
  • To investigate the noise attenuation effects of various vegetation configurations, noise levels on 6 study sites along relatively heavy traffic roads were measured. The differences between noise level measures at 1m and 10m spots from the road range from 10 to 15dB depending upon the attributes of the vegetation. When flat grass land was set to control plot, the maximum noise attenuation at 10m spot was measured at the densely planted shrubs with 5dB difference. The areas on upward slope from the road showed the least attenuation effects. Based on the study results, an appropriate setting for low level residential area noise buffer belt would be densely planted shrubs with at least 3m width and 2m height. To be effective, 3m width soft areas covered with grasses are needed at the front and behind sides of the belt. More than 15dB of the noise level caused by the road traffic would be attenuated with the prescription.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

Association Between Pelvic Bone Computed Tomography-Derived Body Composition and Patient Outcomes in Older Adults With Proximal Femur Fracture

  • Tae Ran Ahn;Young Cheol Yoon;Hyun Su Kim;Kyunga Kim;Ji Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.5
    • /
    • pp.434-443
    • /
    • 2023
  • Objective: To investigate the association between pelvic bone computed tomography (CT)-derived body composition and patient outcomes in older adult patients who underwent surgery for proximal femur fractures. Materials and Methods: We retrospectively identified consecutive patients aged ≥ 65 years who underwent pelvic bone CT and subsequent surgery for proximal femur fractures between July 2018 and September 2021. Eight CT metrics were calculated from the cross-sectional area and attenuation of the subcutaneous fat and muscle, including the thigh subcutaneous fat (TSF) index, TSF attenuation, thigh muscle (TM) index, TM attenuation, gluteus maximus (GM) index, GM attenuation, gluteus medius and minimus (Gmm) index, and Gmm attenuation. The patients were dichotomized using the median value of each metric. Multivariable Cox regression and logistic regression models were used to determine the association between CT metrics with overall survival (OS) and postsurgical intensive care unit (ICU) admission, respectively. Results: A total of 372 patients (median age, 80.5 years; interquartile range, 76.0-85.0 years; 285 females) were included. TSF attenuation above the median (adjusted hazard ratio [HR], 2.39; 95% confidence interval [CI], 1.41-4.05), GM index below the median (adjusted HR, 2.63; 95% CI, 1.33-5.26), and Gmm index below the median (adjusted HR, 2.33; 95% CI, 1.12-4.55) were independently associated with shorter OS. TSF index (adjusted odds ratio [OR], 6.67; 95% CI, 3.13-14.29), GM index (adjusted OR, 3.45; 95% CI, 1.49-7.69), GM attenuation (adjusted OR, 2.33; 95% CI, 1.02-5.56), Gmm index (adjusted OR, 2.70; 95% CI, 1.22-5.88), and Gmm attenuation (adjusted OR, 2.22; 95% CI, 1.01-5.00) below the median were independently associated with ICU admission. Conclusion: In older adult patients who underwent surgery for proximal femur fracture, low muscle indices of the GM and gluteus medius/minimus obtained from their cross-sectional areas on preoperative pelvic bone CT were significant prognostic markers for predicting high mortality and postsurgical ICU admission.

Hydrochemistry of an alluvial aquifer in the Cheonan area: role of the pyrite oxidation on denitrification

  • Kim, Kyoung-Ho;Yun, Seong-Taek;Chae, Gi-Tak;Heo, Chul-Ho;Kim, Hyoung-Soo;Rhee, Chul-Woo;Kim, Kangjoo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.287-290
    • /
    • 2002
  • To examine the denitrification process in an alluvial aquifer in the Cheonan site, hydrological and hydrogeochemical studies were carried out. Elevated levels of NO$_3$ (maximum 77.6 mg/L) were observed in shallow groundwaters of the area, as a result of poultry and agricultural activity. However, the nitrate concentrations were found to be consistently attenuated down to very low levels (<1.0 mg/L). The abrupt removal of nitrate coincided with the pattern of redox change and indicated that denitrification is the most plausible process. The hydrochemistry and mass balance approach using geochemical modeling (phreeqc 2.0) and redox chemistry indicated that chemo-autotrophic denitrification via pyrite oxidation is the key Process to control the nitrate attenuation in the study area.

  • PDF

Impact of Model-Based Iterative Reconstruction on the Correlation between Computed Tomography Quantification of a Low Lung Attenuation Area and Airway Measurements and Pulmonary Function Test Results in Normal Subjects

  • Kim, Da Jung;Kim, Cherry;Shin, Chol;Lee, Seung Ku;Ko, Chang Sub;Lee, Ki Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1187-1195
    • /
    • 2018
  • Objective: To compare correlations between pulmonary function test (PFT) results and different reconstruction algorithms and to suggest the optimal reconstruction protocol for computed tomography (CT) quantification of low lung attenuation areas and airways in healthy individuals. Materials and Methods: A total of 259 subjects with normal PFT and chest CT results were included. CT scans were reconstructed using filtered back projection, hybrid-iterative reconstruction, and model-based IR (MIR). For quantitative analysis, the emphysema index (EI) and wall area percentage (WA%) were determined. Subgroup analysis according to smoking history was also performed. Results: The EIs of all the reconstruction algorithms correlated significantly with the forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) (all p < 0.001). The EI of MIR showed the strongest correlation with FEV1/FVC (r = -0.437). WA% showed a significant correlation with FEV1 in all the reconstruction algorithms (all p < 0.05) correlated significantly with FEV1/FVC for MIR only (p < 0.001). The WA% of MIR showed the strongest correlations with FEV1 (r = -0.205) and FEV1/FVC (r = -0.250). In subgroup analysis, the EI of MIR had the strongest correlation with PFT in both eversmoker and never-smoker subgroups, although there was no significant difference in the EI between the reconstruction algorithms. WA% of MIR showed a significantly thinner airway thickness than the other algorithms ($49.7{\pm}7.6$ in ever-smokers and $49.5{\pm}7.5$ in never-smokers, all p < 0.001), and also showed the strongest correlation with PFT in both ever-smoker and never-smoker subgroups. Conclusion: CT quantification of low lung attenuation areas and airways by means of MIR showed the strongest correlation with PFT results among the algorithms used, in normal subjects.

Analysis of Ground Vibration Characteristics by Test Blasting in Southern Region of Jeju (제주 남부지역의 시험발파에 의한 지반진동 특성 분석)

  • Kim, Seung Hyun;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.419-429
    • /
    • 2019
  • The characteristics of ground vibration have been analyzed by test blasting in southern region of Jeju (layered ground consisting of basalt and clinker). By grasping the principal component of ground vibration and depriving the prediction equations of ground vibration, the propagation characteristics of ground vibration have been compared to the domestic design guidelines. Ground vibration in layered ground has a small amplitude at a short distance. However, it has been confirmed that the vibration energy is transmitted further by virtue of the low attenuation of the ground vibration as it goes to a longer distance. Moreover, the frequency has been confirmed to be low frequency band. The outcome has been defined that it resulted because the clinker layer with a large pore transforms the blasting energy seismic wave with high frequency into a low frequency wave having a long waveform period. In addition, the limits of design guidelines were identified by comparing the ground vibration of Jeju and other bedrock areas. Thus, the necessity of the development of the prediction equations of ground vibration utilized in design that reflect the characteristics of the area has been suggested.

천안.원주 불량매립지의 침출수 저감연구

  • Lee Jin-Yong;Yun Hui-Seong;Lee Seong-Sun;Cheon Jeong-Yong;Gwon Hyeong-Pyo;Kim Jong-Ho;Kim Chang-Gyun;Park Jeong-Gu
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.398-401
    • /
    • 2006
  • Two landfills of this study containing municipal wastes without any bottom liner and leachate treatment system have different landfill age, waste volume and most importantly different hydrogeologic settings. The one (Cheonan) is situated in an open flat area while the other (Wonju) is located in a valley. In the interior of the landfills, typical anaerobic conditions revealed by low DO and ${NO_3}^-$ concentrations, negative ORP values, high $NH_3$, alkalinity and $Cl^-$ concentrations were observed. Generally higher levels of contaminants were detected in the dry season while those were greatly lowered in the wet season. Significantly large decrease of Cl concentration in the wet season indicates that the dilution or mixing is one of dominant attenuation mechanisms of leachate. But detailed variation behaviors in the two landfills are largely different and they were most dependent on permeability of surface and subsurface layers. The intermediately permeable surface of 1.he landfills receives part of direct rainfall infiltration but most rainwater is lost to fast runoff. The practically impermeable surface of clayey silt (paddy field) at immediately adjacent to the Cheonan landfill boundary prevented direct rainwater infiltration and hence redox condition of the groundwaters were largely affected by that of the upper landfill and the less permeable materials beneath the paddy fields prohibited dispersion of the landfill leachate into downgradient area. In the Wonju landfill, there exist three different permeability divisions, the landfill region, the sandy open field and the paddy field. Roles of the landfill and paddy regions are very similar to those at the Cheonan. The very permeable sandy field receiving a large amount of rainwater infiltration plays a key role in controlling redox condition of the downgradient area and contaminant migration.

  • PDF

Optical Properties of Ocean Water and Marine Primary Production -A Study on the Oligotrophic Zone in the Eastern Tropical Atlantic Ocean- (해수의 광학적 성질과 해양기초생산 -동열대 대서양 Oligotrophic zone을 중심으로-)

  • YOON Hong-Joo;RYU Cheong-Ro;KIM Ki-Tae;KIM Hyeon-Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.174-182
    • /
    • 1995
  • Using the optical data from the EUMELI 3 and 4 missions, the optical properties are discussed in relation to primary production in the oligotrophic zone of the Eastern Atlantic Ocean. The depth of euphotic layer $(Z_{eu})$, the total accumulated concentration of pigment $(C_{TOT})$ and the concentration of pigment (C) are 88m, $12.4mgm^{-2}\;and\;0.14mgm^{-3}$, respectively for the EUMELI 3 mission and 101.7m, $10.0mgm^{-2}\;and\;0.10mgm^{-3}$, respectively for the EUMELI 4 mission. The concentration of pigment is higher in autumn (EUMELI 3) than in spring (EUMELI 4). This indicates that the concentration of photosynthetic pigment has a close correlation with vertical attenuation coefficient $(K(\lambda))$ that changes seasonally in the euphotic layer. While the spectral distributions of downward Irradiance$(E_d)$ for the wave length of 470nm increase with depth, those of upward irradiance $(E_u)$ for the wave length range between 410nm and 490nm are constant, because the study area is covered with the blue and clear oceanic deep waters. The vertical attenuation coefficients of downward irradiance $(K_d)$ and upward irradiance $(K_u)$ have low values between 0.02 and $0.06m^{-1}$ due to the low absorption and scattering by the photosynthetic pigment of phytoplankton. Therefore this zone has the characteristics of the case 1 waters with low concentrations of photosynthetic pigment, and can be classifed into IB.

  • PDF