• 제목/요약/키워드: Low Voltage Capacitor

검색결과 529건 처리시간 0.02초

Analysis of an Interleaved Resonant Converter for High Voltage and High Current Applications

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1632-1642
    • /
    • 2014
  • This paper presents an interleaved resonant converter to reduce the voltage stress of power MOSFETs and achieve high circuit efficiency. Two half-bridge converters are connected in series at high voltage side to limit MOSFETs at $V_{in}/2$ voltage stress. Flying capacitor is used between two series half-bridge converters to balance two input capacitor voltages in each switching cycle. Variable switching frequency scheme is used to control the output voltage. The resonant circuit is operated at the inductive load. Thus, the input current of the resonant circuit is lagging to the fundamental input voltage. Power MOSFETs can be turn on under zero voltage switching. Two resonant circuits are connected in parallel to reduce the current stress of transformer windings and rectifier diodes at low voltage side. Interleaved pulse-width modulation is adopted to decrease the output ripple current. Finally, experiments are presented to demonstrate the performance of the proposed converter.

수동형 필터 적용시 무효전력의 변화에 관한 연구 (Study on the Variation of Reactive Power When Applying the Passive Filter)

  • 김지명;김종겸
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

A Control Technique for 120Hz DC Output Ripple-Voltage Suppression Using BIFRED with a Small-Sized Energy Storage Capacitor

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.190-197
    • /
    • 2005
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still maintains generally good performance such as low THD of input line current and a high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and smaller size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

Single-Ended High-Efficiency Step-up Converter Using the Isolated Switched-Capacitor Cell

  • Kim, Do-Hyun;Jang, Jong-Ho;Park, Joung-Hu;Kim, Jung-Won
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.766-778
    • /
    • 2013
  • The depletion of natural resources and renewable energy sources, such as photovoltaic (PV) energy, has been highlighted for global energy solution. The PV power control unit in the PV power-generation technology requires a high step-up DC-DC converter. The conventional step-up DC-DC converter has low efficiency and limited step-up ratio. To overcome these problems, a novel high step-up DC-DC converter using an isolated switched capacitor cell is proposed. The step-up converter uses the proposed transformer and employs the switched-capacitor cell to enable integration with the boost inductor. The output of the boost converter and isolated switched-capacitor cell are connected in series to obtain high step-up with low turn-on ratio. A hardware prototype with 30 V to 40 V input voltage and 340 V output voltage is implemented to verify the performance of the proposed converter. As an extended version, another novel high step-up isolated switched-capacitor single-ended DC-DC converter integrated with a tapped-inductor (TI) boost converter is proposed. The TI boost converter and isolated-switched-capacitor outputs are connected in series to achieve high step-up. All magnetic components are integrated in a single magnetic core to lower costs. A prototype hardware with 20 V to 40 V input voltage, 340 V output voltage, and 100 W output power is implemented to verify the performance of the proposed converter.

High Efficiency High-Step-up Single-ended DC-DC Converter with Small Output Voltage Ripple

  • Kim, Do-Hyun;Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1468-1479
    • /
    • 2015
  • Renewable energy resources such as wind and photovoltaic power generation systems demand a high step-up DC-DC converters to convert the low voltage to commercial grid voltage. However, the high step-up converter using a transformer has limitations of high voltage stresses of switches and diodes when the transformer winding ratio increases. Accordingly, conventional studies have been applied to series-connect multioutput converters such as forward-flyback and switched-capacitor flyback to reduce the transformer winding ratio. This paper proposes new single-ended converter topologies of an isolation type and a non-isolation type to improve power efficiency, cost-effectiveness, and output ripple. The first proposal is an isolation-type charge-pump switched-capacitor flyback converter that includes an extreme-ratio isolation switched-capacitor cell with a chargepump circuit. It reduces the transformer winding number and the output ripple, and further improves power efficiency without any cost increase. The next proposal is a non-isolation charge-pump switched-capacitor-flyback tapped-inductor boost converter, which adds a charge-pump-connected flyback circuit to the conventional switched-capacitor boost converter to improve the power efficiency and to reduce the efficiency degradation from the input variation. In this paper, the operation principle of the proposed scheme is presented with the experimental results of the 100 W DC-DC converter for verification.

보조 권선형 능동 스너버를 적용하여 낮은 스위치 서지 전압 특성을 갖는 유사 공진형 컨버터에 관한 연구 (A Study on Quasi Resonant Converter with Low Switching Surge Voltage Characteristics by Applying Auxiliary Winding Type Active Snubber)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.56-61
    • /
    • 2018
  • In this paper, a new type of active snubber was proposed to lower the excessive rated voltage of the clamp capacitor which was a problem in the conventional circuit by applying auxiliary winding into the active snubber. A simplified equivalent circuit of the proposed snubber was derived by applying it to QR flyback converter, and the equivalent circuits for each switch state was shown under the steady-state condition. In addition, the maximum voltage of the clamp capacitor as well as the main switch was found by using the steady-state equations. In particular, it was found that the clamp capacitor voltage could be controlled by the auxiliary winding ratio. In order to verify the utility and practicality of the proposed converter with auxiliary winding type active snubber circuit, a prototype with an output voltage of 19V and a maximum load current of 6A was produced and the results were reported.

순간적인 전압강하 및 순간 전압 융기 발생시 전력용 커패시터의 특성 해석 (Characteristics Analysis of Power Capacitor at Sag & Swell)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.21-28
    • /
    • 2009
  • 전력용 커패시터는 유도성 부하의 갖은 역율을 보상하기 위해 사용되지만, 전력변환장치 등에 의해 발생하는 고조파를 저감하기 위해 리액터와 함께 사용하기도 한다. 전기품질은 대부분이 전압품질에 관련된 것으로서 부하의 안정적인 동작에 매우 중요하지만, 순간적인 전압강하 또는 순간 전압 융기 발생시와 같이 전압의 크기가 일시적으로 변할 경우 커패시터에 전기적인 스트레스로 작용할 수 있다. 본 연구에서는 순간적인 전압강하 및 순간 전압 융기 발생시 커패시터에서의 전압, 전류 및 용량의 변화를 해석하였으며, 커패시터에 리액터를 설치할 경우 순간적인 전압 강하시는 문제가 되지 않지만, 순간 전압 융기 발생 영역에서는 커패시터에 상당한 스트레스를 줄 수 있다는 것을 확인할 수 있었다.

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계 (A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads)

  • 이우철;이택기
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

A Novel High Step-Up Converter with a Switched-Coupled-Inductor-Capacitor Structure for Sustainable Energy Systems

  • Liu, Hongchen;Ai, Jian;Li, Fei
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.436-446
    • /
    • 2016
  • A novel step-up DC-DC converter with a switched-coupled-inductor-capacitor (SCIC) which successfully integrates three-winding coupled inductors and switched-capacitor techniques is proposed in this paper. The primary side of the coupled inductors for the SCIC is charged by the input source, and the capacitors are charged in parallel and discharged in series by the secondary windings of the coupled inductor to achieve a high step-up voltage gain with an appropriate duty ratio. In addition, the passive lossless clamped circuits recycle the leakage energy and reduce the voltage stress on the main switch effectively, and the reverse-recovery problem of the diodes is alleviated by the leakage inductor. Thus, the efficiency can be improved. The operating principle and steady-state analyses of the converter are discussed in detail. Finally, a prototype circuit at a 50 kHz switching frequency with a 20-V input voltage, a 200-V output voltage, and a 200-W output power is built in the laboratory to verify the performance of the proposed converter.