• 제목/요약/키워드: Low Power Test

검색결과 1,415건 처리시간 0.038초

근전도를 이용한 Sorensen 검사시 성인남녀 등 근육의 근피로도 분석 (Spectral Electromyographic Fatigue Analysis of Back Muscles in Healthy Adult Men and Women During Sorensen Test)

  • 이미선;김태영
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.63-71
    • /
    • 1998
  • Trunk holding test (Sorensen test) appear to have more value than strength test in prediction the occurrence of low back pain. Electromyographic activity of trunk extensor muscles during these test may provide clues to the etiology of neuromuscular-based low back pain. This study investigated the difference in back muscle endurance between healthy adult men and women using surface electromyographic (EMG) power spectral analysis. Thirty hea1thy subjects (15 men and 15 women) performed an unsupported trunk holding test for 60 seconds. Recording surface electrodes were placed over the erector spinae medially and laterally at vertebral levels of $L_1$ and $L_5$. Slope of total frequency was evaluated using the MP100WSW Fast Fourier Transform spectrum analysis program. The slopes of all indices of back muscle fatigue, except right $L_5$, were significantly steeper in men than in women (p<0.05). Our results indicated that the trunk holding test using EMG power spectral analysis of erector spinae muscles is useful for the evaluation of fatigue rate of these muscles. Our results also showed a higher muscle endurance in healthy adult women than in men.

  • PDF

Glass Formulations for Vitrification of Low- and Intermediate-level Waste

  • Kim, Cheon-Woo;Park, Jong-Kil;Ha, Jong-Hyun;Song, Myung-Jae;Lee, Nel-Son;Kong, Peter-C.;Anderson, Gary-L.
    • 한국세라믹학회지
    • /
    • 제40권10호
    • /
    • pp.936-942
    • /
    • 2003
  • In order to develop glass formulations for vitrifying Low-and Intermediate-Level radioactive Wastes (LILW) from nuclear power plants of Korea Hydro & Nuclear Power (KHNP) Co., Ltd., promising glass formulations were selected based on glass property model predictions for viscosity, electrical conductivity and leach resistance. Laboratory measurements were conducted to verify the model predictions. Based on the results, the models for electrical conductivity, US DOE 7-day Product Consistency Test (PCT) elemental release, and pH of PCT leachate are accurate for the LILW glass formulations. However, the model for viscosity was able to provide only qualitative results. A leachate conductivity test was conducted on several samples to estimate glass leach resistance. Test results from the leachate conductivity test were useful for comparison before PCT elemental release results were available. A glass formulation K11A meets all the KHNP glass property constraints, and use of this glass formulation on the pilot scale is recommended. Glass formulations K12A, K12B, and K12E meet nearly all of the processing constraints and may be suitable for additional testing. Based on the comparison between the measured and predicted glass properties, existing glass property models may be used to assist with the LILW glass formulation development.

Effects of the Vestibular Caloric Stimulation with Ice Water on the Autonomic Nervous System

  • Kim, Chungyoo;Kang, Jongho
    • 대한통합의학회지
    • /
    • 제4권3호
    • /
    • pp.27-30
    • /
    • 2016
  • PURPOSE : The effect of the vestibular caloric stimulation with ice water on the autonomic nervous system was investigated using pulse oximetry. METHOD : Thirty-four healthy men and women were subject to a 2-minute vestibular caloric stimulation with ice water, and autonomic nervous activities (low frequency, high frequency, and total power) were measured before and after the vestibular caloric stimulation. Data were analyzed separately for men and women. RESULT : Low frequency, high frequency, and total power in the men and low frequency in the women were statistically significantly higher after vestibular caloric stimulation. High frequency and total power in the women were higher but not significantly different after vestibular caloric stimulation. CONCLUSION : Vestibular caloric stimulation with ice water increases autonomic nervous activities, with the variation being within the normal range. The test can be considered safe for use.

Master-Slave 기법을 적용한 System Operation의 동작 검증 (Verification of System using Master-Slave Structure)

  • 김인수;민형복
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.199-202
    • /
    • 2009
  • Scan design is currently the most widely used structured Design For Testability approach. In scan design, all storage elements are replaced with scan cells, which are then configured as one or more shift registers(also called scan chains) during the shift operation. As a result, all inputs to the combinational logic, including those driven by scan cells, can be controlled and all outputs from the combinational logic, including those driving scan cells, can be observed. The scan inserted design, called scan design, is operated in three modes: normal mode, shift mode, and capture mode. Circuit operations with associated clock cycles conducted in these three modes are referred to as normal operation, shift operation, and capture operation, respectively. In spite of these, scan design methodology has defects. They are power dissipation problem and test time during test application. We propose a new methodology about scan shift clock operation and present low power scan design and short test time.

전력기기용 Al/Cu 복합 부스바의 통전용량 설계 및 특성 평가 (Transport Capacity Design and Characteristics Evaluation of Al/Cu Composite Busbar for Power Equipments)

  • 배준한;김해준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.628-632
    • /
    • 2006
  • This paper deals with the electric and thermal characteristics of the composite busbar composed of aluminum and copper. When AC current is flowing in Cu busbar used widely in conservative equipments like power cable, transformer, and switchgear & controlgear most current is concentrated on the surface of the busbar by the skin effect. Therefore, if the Cu region in the busbar having low current density is replaced with aluminum, we can largely reduce the product cost and weight of the busbar. To conform the performance of the composite busbar, we designed and fabricated a test Al/Cu composite busbar. Maximun temperature rise of the busbar was $35^{\circ}C$ when 1600 Arms of AC current was applied to the test composite busbar($120mm{\times}10mm$). Based on test results, we can expect to make the low-priced and light power equipments using the Al/Cu composite busbar.

저궤도위성의 전력계 및 자세제어계 고장 관리 설계 검증시험 (Fault Management Design Verification Test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit Satellite)

  • 이상록;전현진;전문진;임성빈
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.14-23
    • /
    • 2013
  • 위성 운용 중 발생할 수 있는 오류에 대한 대비를 고장 관리 설계라고 한다. 고장 관리 설계는 위성에 이상 현상이 나타나는 경우 감지하고 고립시키며, 지상에서 위성과 접속한 이후 오류 사항을 파악하고 대응책을 마련할 때까지 위성을 안전한 상태로 유지하는 기능을 포함한다. 안전 모드 운용은 정상 운용과는 다르게 비행 소프트웨어를 탑재한 탑재 컴퓨터와 전력 제어 및 분배 장치 주관 하에 지상국의 접속 없이 이루어진다. 오류 발생 시 고장 관리 설계에 따라 자동화된 동작이 이루어지는 만큼 지상 시험 단계에서 고장 관리 로직 및 관련 하드웨어가 설계된 대로 동작하는지를 철저하게 검증해야 한다. 또한 실제와 유사한 오류를 위성에 손상 없이 인가해야 한다. 고장 관리 설계 검증시험은 위성을 구성하는 다양한 부분체에 대해서 수행되나 본 논문에서는 저궤도 위성의 비행 모델을 대상으로 수행된 자세제어계와 전력계 시험의 설계에 대해 서술하고 결과에 대해 정리하였다.

원자력발전소용 Motor Control Center의 내진검증시험 (Seismic Qualification Test on Motor Control Center for Use in Nuclear Power Plants)

  • 김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.217-224
    • /
    • 1997
  • The safety related equipments for use in nuclear power plants should be subjected to the seismic qualification in order to insure the safety of the nuclear power plant. This paper summarizes the seismic qualification test on the Low Voltage Motor Control Centers(MCC's) for use in Wolsong Nuclear Power Plants, Units 2, 3 and 4. The seismic qualification test was performed on the two prototype MCC's(a two-bay wide unit for Phase #1 Test and a five-bay wide unit for Phase #2 Test). The specimens were electrically powered and monitored during the test process. It was demonstrated that the specimens possessed sufficient structural and electrical integrity to withstand the required seismic conditions.

  • PDF

야생식생군락 생태계 모니터링을 위한 사물인터넷 기반의 저전력 무선 센서네트워크 시스템에 관한 연구 (Study on Internet of Things Based Low-Power Wireless Sensor Network System for Wild Vegetation Communities Ecological Monitoring)

  • 김내수;이계선;류재홍
    • 한국IT서비스학회지
    • /
    • 제14권1호
    • /
    • pp.159-173
    • /
    • 2015
  • This paper presents a study on the Internet of Things based low-power wireless sensor networks for remote monitoring of wildlife ecosystem due to climate change. Especially, it is targeting the wild vegetation communities ecological monitoring. First, we performed a pre-test and analysis for selecting the appropriate frequency for the sensor network to collect and deliver information reliably in harsh propagation environment of the forest area, and selected for sensors for monitoring wild vegetation communities on the basis of considerations for selecting the best sensor. In addition, we have presented the platform concept and hierarchical function structures for effectively monitoring, analyzing and predicting of ecosystem changes, to apply the Internet of Things in the ecological monitoring area. Based on this, this paper presents the system architecture and design of the Internet of Things based low-power wireless sensor networks for monitoring the ecosystem of the wild vegetation communities. Finally, we constructed and operated the test-bed applied to real wild trees, using the developed prototype based on the design.

저전력 테스트를 고려한 효율적인 테스트 데이터 압축 방법 (An Efficient Test Data Compression/Decompression for Low Power Testing)

  • 전성훈;임정빈;김근배;안진호;강성호
    • 대한전자공학회논문지SD
    • /
    • 제42권2호
    • /
    • pp.73-82
    • /
    • 2005
  • 스캔 테스트를 위한 테스트 데이터의 양과 파워 소모는 SoC 테스트에서의 최근의 직면한 가장 큰 문제들이다. 따라서 본 논문에서는 저전력 테스트를 고려한 새로운 테스트 데이터 압축 방법을 제안한다. 제안하는 압축 방법은 테스트 데이터 압축을 위해 압축율, 전력 소모 감소율과 하드웨어 오버헤드를 고려하여 최대 효율을 가지도록 하는데 기초하고 있다. 압축율과 전력 감소율을 높이기 위해서 본 논문에서는 IR (Input Reduction) 기법과 MSCIR (Modified Statistical Code using Input Reduction) 압축 코드을 사용하며, 뿐만아니라 이를 위한 사전 작업인 새로운 스캔 플립플롭 순서 재조합 기법 및 테스트 패턴 순서 재조합 방법을 제안한다. 기존의 연구와는 달리 CSR 구조를 사용하지 않고 원래의 테스트 데이터 $T_D$를 사용하여 압축하는 방법을 사용한다. 이렇게 함으로써 제안하는 압축 방법은 기존의 연구에 비해 훨씬 높은 압축율을 가지며 낮은 하드웨어 오버헤드의 디컴프레션 구조와 적은 전력 소모를 가진다. ISCAS '89 벤치 회로에 대찬 기존의 연구와의 비교로서 그 결과를 알 수 있다.