• 제목/요약/키워드: Low Power Test

검색결과 1,422건 처리시간 0.03초

인버터 구동형 저압 유동전동기의 절연특성 분석 (Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters)

  • 박도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

유전가열에 의한 고강도-저발포 스티로폼 개발 II (Development of low foamed-high strengthen styrofoam by dielectric heating II)

  • 한두희
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2001년도 춘계학술대회 발표논문집
    • /
    • pp.281-283
    • /
    • 2001
  • The low foamed high strengthen styrofoam samples made by dielectric heating are discussed. We used the oscillator which have the frequency of 13.6MHz and the Power of 7kW. 3 times expanded beads by steaming method were used in our foam-molding test. Internal fusion properties and density of internal structure were improved by dielectric foaming process. At the temperature of 105-110$^{\circ}C$, the internal fusion property was maximally improved.

1D AND 3D ANALYSES OF THE ZY2 SCIP BWR RAMP TESTS WITH THE FUEL CODES METEOR AND ALCYONE

  • Sercombe, J.;Agard, M.;Struzik, C.;Michel, B.;Thouvenin, G.;Poussard, C.;Kallstrom, K.R.
    • Nuclear Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.187-198
    • /
    • 2009
  • In this paper, three power ramp tests performed on high burn-up Re-crystallized Zircaloy2 - UO2 BWR fuel rods (56 to 63 MWd/kgU) within the SCIP project are simulated with METEOR and ALCYONE 3D. Two of the ramp tests are of staircase type up to Linear Heat Rates of 420 and 520 W/cm and with long holding periods. Failure of the 420 W/cm fuel rod was observed after 40 minutes. The third ramp test consisted of a more standard ramp test with a constant power rate of 80 W/cm/min up to 410 W/cm with a short holding time. The tests were first simulated with the METEOR 1D fuel rod code, which gave accurate results in terms of profilometry and fission gas releases. The behaviour of a fuel pellet fragment and of the cladding piece on top of it was then investigated with ALCYONE 3D. The size and the main characteristics of the ridges after base irradiation and power ramp testing were recovered. Finally, the failure criteria validated for PWR conditions and fuel rods with low-to-medium burn-ups were used to analyze the failure probability of the KKL rodlets during ramp testing.

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구 (Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 이용성;김정윤;이정용;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

임펄스전압에 대한 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages)

  • 이복희;장석훈;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

Turbine Performance Experiments for the Turbopump of a Liquid Rocket Engine

  • Lee, Hanggi;Shin, Juhyun;Jeong, Eunhwan;Choi, Changho
    • International Journal of Aerospace System Engineering
    • /
    • 제3권1호
    • /
    • pp.25-29
    • /
    • 2016
  • This paper highlights the performance of an impulse turbine which is a part of turbopump in a liquid rocket first stage engine. The turbopump, currently under development at Korea Aerospace Research Institute, has an impulse type turbine with 12 nozzles and a single rotor. The impulse turbine can archive high specific power with the low gas flow rates. The supersonic impulse turbine with a single rotor can make a simple structure. High-pressure gases are converted into the dynamic energy with flows through the 12 nozzles and drive the rotor to make the power for the pumps. The turbine test was performed in the high-pressured turbine test facility with air gas instead of burned gas. A hydraulic dynamometer was used to absorb the power from the turbine and control the rotational speed and torque. The test points were at several pressure ratios with 7 different rotational speeds. Results showed the efficiency was highest at the design pressure ratio. The efficiency was insensitive to the pressure ratio variation than the rotational speed. It was a typical characteristic in an impulse turbine.

BIST 환경에서의 천이 억제 스캔 셀 구조 (Transition Repression Architecture for scan CEll (TRACE) in a BIST environment)

  • 김인철;송동섭;김유빈;김기철;강성호
    • 대한전자공학회논문지SD
    • /
    • 제43권6호
    • /
    • pp.30-37
    • /
    • 2006
  • 본 논문은 테스트 수행 중 발생하는 전력 소모를 줄이기 위한 변경된 스캔 셀 구조를 제안하고 있다. 이는 스캔 이동 중에 조합 회로 부분에서 발생하는 천이를 억제할 뿐 아니라 동시에 스캔 체인 내에서 발생하는 천이도 감소시킨다. 뿐만 아니라 캡쳐 싸이클에서 발생하는 천이 또한 제한시킨다. 제안하는 방식은 test-per-scan BIST 구조에 적합하고 싱글 스캔 구조 뿐 아니라 멀티 스캔 구조에도 적응 가능하다. 실험 결과는 제안하는 방법이 기존의 방법들과 비슷한 수준의 고장 검출율을 가지면서 보다 적은 전력을 소모한다는 것을 보여준다.

가동 철심형 용접기와 정현파를 출력하는 디지털 용접기의 3점식 굽힘시험을 이용한 용접성 비교 분석 (Comparative analysis of weldability using a three-point bending test of a movable iron core welder and a digital welder that outputs a sine wave)

  • 김종식;이광호;주이환;고종철;윤경열
    • 문화기술의 융합
    • /
    • 제9권1호
    • /
    • pp.605-611
    • /
    • 2023
  • 본 연구에서는 자연환경에 영향을 주는 에너지를 절감하기 위해 피복아크용접에서 가동철심형 용접기와 전력사용량이 적은 디지털 용접기(인버터 방식)를 비교하여 전력 사용은 적으며 용접성은 동일한 조건을 갖춰야 하는 부분을 확인하고자 한다. 가동철심형 용접기는 정현파를 출력하는 교류를 사용하며 디지털 용접기 또한 정현파 교류를 발생시켜 동일 조건을 갖추고 전력사용량은 적으며 같은 용접성을 갖추어야 한다. 다만 용접성은 다양하게 검증할 수 있으나 국가기술자격 용접 분야의 자격시험으로 한정하여 분석하고자 한다.

터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여- (A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop-)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제6권1호
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF

성조숙 증상을 보이는 여아들의 HRV의 특성 연구 (A Study of the Characteristics of the HRV of the Girl Showing a Precocious Puberty)

  • 양승정;박경미;조성희
    • 대한한방부인과학회지
    • /
    • 제29권3호
    • /
    • pp.10-22
    • /
    • 2016
  • Objectives: The aim of the study was to investigate the characteristics of the autonomic innervation of the heart in Precocious Puberty (PP) Girls.Methods: We studied 87 girls visiting Dongshin University Suncheon Oriental Medicine hospital from first Januarty 2013 to 31th December 2015. Among the 87 girls who were selected 14 people under the age of 8. The subjects were categorized in two groups, 2 PP girls and 12 healthy controls. We studied the difference of Heart rate variability (HRV) between two groups by Independent samples T-test using SPSS for windows (version 22.0).Results: The Standard deviation of all normal R-R intervals (SDNN), The spuare root of the sum of the spuare of difference between adjacent normal R-R intervals (RMS-SD) of PP group was non-significantly lower than non-PP group. Total power (TP), Very low frequency power (VLF), High frequency power (HF), Low frequency power (LF) of PP group was non-significantly lower than non-PP group, LF/HF ratio of PP group was significantly higher than non-PP group. Normalized high frequency power (HF norm) of PP group was non-significantly lower than non-PP group. Normalized low frequency power (LF norm) of PP was non-signficantly higher than non-PP group.Conclusion: The results suggest that imbalance of sympathetic and parasympathetic nervous system from girls of precocious puberty can be seen.