저속풍동실험 및 유동해석을 통한 고속전철 판토그라프의 유동소음 해석 (Prediction of Aeroacoustics Noise of Pantograph via Low Speed Wind Tunnel Test and Flow Simulation)

  • 조운기;이종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1207-1214
    • /
    • 2001
  • The paper deals with the computational approach in analysis and design of pantograph panhead strips of high-speed railway in aerodynamic and aeroacoustic concerns. Pantograph is an equipment such that the electric power is supplied from catenary system to train. Due to the nature of complexity in high-speed fluid flow, turbulence and downstream vortices result in the instability in the aerodynamic contact between panhead strips and catenary system, and consequently generate the considerable levels of flow-induced sound. In this paper, based on the preceding low speed wind-tunnel test and simulations, the aerodynamic and aeroacoustic characteristics in low speed are analyzed.

  • PDF

굴착잔토를 재활용한 지중 전력케이블 유동성 뒤채움재의 열저항 특성 (Thermal Resistant Characteristics of Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities)

  • 오기대;김대홍
    • 한국지반환경공학회 논문집
    • /
    • 제11권10호
    • /
    • pp.15-24
    • /
    • 2010
  • 지중전력선은 연성관을 다발로 지하에 매설함으로 관의 하단부 다짐효율이 낮아 파손 등과 같은 구조적 문제점에 항상 노출되어 있고 이러한 문제점을 해결하기 위해서 다양한 방법들이 강구되어 왔으며 그중 하나가 유동성이 뛰어난 저강도 콘크리트의 개발이다. 그러나 지중전력선 뒤채움재는 이러한 구조적 안정성 뿐만 아니라 전력선에서 발생하는 열을 효율적으로 외부로 배출시키는 우수한 열적 특성도 동시에 요구된다. 따라서 본 연구에서는 급결성 유동성 뒤채움재의 물리, 역학적 조건에 따른 열 저항특성을 파악하고자 한다. 국내 토질조건을 고려하여 풍화토, 자갈, 점토를 혼합한 혼합토 총 17종류의 다양한 토양에 대해서 고화재를 적용하여 물리, 역학적 특성(함수비, 단위 중량, 간극비, 양생 시간)에 따른 열저항 특성을 파악하고, 현장의 적용성을 확인하고자 실증실험을 수행하였다. 연구결과, 실제 지반조건과 유사한 17종 혼합토에 대해서 수축팽창, 양생조건을 고려한 실내실험과 현장토에 대해서 실험을 수행한 결과, 다양한 현장조건에 대해서 $85^{\circ}C\;cm/W$ 이하 열 저항성 값으로 우수한 열특성을 나타냈다.

회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구 (A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler)

  • 박성제;홍용주;김효봉;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF

고출력 마이크로파 Resonant Ring (High Power Microwave Resonant Ring)

  • 박성수;박상욱;김상희;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1275-1277
    • /
    • 1995
  • We designed and constructed an extremly high power s-band traveling wave resonator for the test of high power microwave components using 80MW pulsed klystron with $4{\mu}s$ pulse width. The 10dB directional coupler for the input power coupling was used, and the ring consists of phase shifter, tuner, H-band, and other microwave components. The designed total electrical length of the system is 10 times of the waveguide wavelength, ${\lambda}_g$=15.3cm, and the measured total insertion loss is 0.15dB. The low power test measurment showed the power multiplication of 14.69. The design goal is to achieve the peak power of 300MW, pulse width $4{\mu}s$ with 30 pulse repetition rate. In this article we discuss the treveling wave resonant ring constructed at the PAL laboratory together with the test results.

  • PDF

내관(內關)-공손(公孫) 자침이 스트레스 상태의 정상성인 자율신경계에 미치는 영향 (Effects of Acupuncture on Autonomic Nervous System in Normal Subjects under Mental Stress)

  • 박성욱;정우상;문상관;박정미;고창남;조기호;김영석;배형섭
    • 대한한의학회지
    • /
    • 제29권2호
    • /
    • pp.107-115
    • /
    • 2008
  • Objectives: The objective of this study was to assess the effects of acupuncture applied at PC6 and SP4 points on heart rate variability (HRV) in normal subjects under mental stress Methods: 24 healthy male subjects were recruited and randomized to a treatment group (12 subjects) or a control group (12 subjects). Both groups performed a mental arithmetic stress test and then acupuncture needles were inserted on PC6 and SP4 for the study group. In the control group, they took sham acupuncture as a control. Heart rate variability (HRV) was measured during the whole study period by FM-150 (digital Holter ECG recorder). Results: In the both groups, low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) was significantly increased after mental stress. Acupuncture induced significant decrease in low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) which were increased after mental stress test. But sham acupuncture induced no changes. Results: In both groups, low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) significantly increased after mental stress. Acupuncture induced significant decrease in low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) which increased after mental stress test. In contrast, sham acupuncture induced no changes. Conclusions: Acupuncture on PC6 and SP4 could be useful to decrease sympathetic activity and balance autonomic nervous system for those who are under stress.

  • PDF

Shaking table test and numerical analysis of nuclear piping under low- and high-frequency earthquake motions

  • Kwag, Shinyoung;Eem, Seunghyun;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi;Chang, Sungjin;Jeon, Bubgyu
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3361-3379
    • /
    • 2022
  • A nuclear power plant (NPP) piping is designed against low-frequency earthquakes. However, earthquakes that can occur at NPP sites in the eastern part of the United States, northern Europe, and Korea are high-frequency earthquakes. Therefore, this study conducts bi-directional shaking table tests on actual-scale NPP piping and studies the response characteristics of low- and high-frequency earthquake motions. Such response characteristics are analyzed by comparing several responses that occur in the piping. Also, based on the test results, a piping numerical analysis model is developed and validated. The piping seismic performance under high-frequency earthquakes is derived. Consequently, the high-frequency excitation caused a large amplification in the measured peak acceleration responses compared to the low-frequency excitation. Conversely, concerning relative displacements, strains, and normal stresses, low-frequency excitation responses were larger than high-frequency excitation responses. Main peak relative displacements and peak normal stresses were 60%-69% and 24%-49% smaller in the high-frequency earthquake response than the low-frequency earthquake response. This phenomenon was noticeable when the earthquake motion intensity was large. The piping numerical model simulated the main natural frequencies and relative displacement responses well. Finally, for the stress limit state, the seismic performance for high-frequency earthquakes was about 2.7 times greater than for low-frequency earthquakes.

30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석 (Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System)

  • 박재범;김미성;노대석
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

대형직접전단시험과 대형삼축시험을 통한 석산골재의 전단거동 특성 비교 (Comparison of Shear Behavior for Quarry Blasted Rocks Based on Large Scale Direct Shear Test and Large Scale Triaxial Test)

  • 이대수;김경열;오기대
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.5-14
    • /
    • 2008
  • 국내 석산에서 생산되는 골재를 사용하여 대형삼축시험과 대형직접전단시험을 동시에 수행한 후 전단특성을 비교하였다. 비교를 위하여 시험조건을 가능한 일치시켰으며, 상대밀도를 50%, 70%, 90%의 세 가지로 변화시켜 시험을 수행하였다. 시험결과 응력-변형률 거동은 두 가지 시험에서 동일하게 나타나며, 전단강도는 상대밀도의 크기에 따라 시험방법별로 추세가 달라진다. 즉, 낮은 상대밀도에서는 대형직접전단시험의 내부마찰각이 대형삼축압축시험 결과 값에 비하여 작게 나타나고, 높은 상대밀도에서는 이 현상이 역전됨을 확인하였다.

IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험 (Field Test on IEC60364-4-44 for the Application in Korean distribution system)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

영상기기와 무선통신이 가능한 저전력 구동의 이너탭 검사시스템 개발 (Development of Low Power Driven Inner Tap Inspection System capable of Wireless Communication with Video Equipment)

  • 안성수
    • 한국멀티미디어학회논문지
    • /
    • 제21권6호
    • /
    • pp.649-658
    • /
    • 2018
  • In this paper, we propose a mechanical contact inner tap inspection system that can inspect the defect of the inner tap immediately after inner tap is processed within the machining center. The inspection module has the collet chuck structure, so it can mounted on the main spindle of the machining center during inspection. It was developed with a focus on inspection for tap having 20 mm depth which is primarily fabricated in automotive parts and has a double sided PCB-type control system including sensing function based on Zigbee module, micom and IR sensor for wireless transmission of measured data with low power operation, and also a battery for supplying electric power. The current consumption is 46.8mA in the inspection operation mode and 0.0268mA in the power saving mode for 3.7V of the applied power source, so that 30,000 times or more inspection can be performed with assumed 5 seconds inspection time for one tap. Experiments in test jig system and actual machining center confirm that the proposed inner tap inspection system can be applied to the batch process of simultaneous inspection after tapping in the machining center.