• Title/Summary/Keyword: Low Power Test

Search Result 1,418, Processing Time 0.031 seconds

Stress status classification based on EEG signals (뇌파 신호 기반 스트레스 상태 분류)

  • Kang, Jun-Su;Jang, Giljin;Lee, Minho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • In daily life, humans get stress very often. Stress is one of the important factors of healthy life and closely related to the quality of life. Too much stress is known to cause hormone imbalance of our body, and it is observed by the brain and bio signals. Based on this, the relationship between brain signal and stress is explored, and brain signal based stress index is proposed in our work. In this study, an EEG measurement device with 32 channels is adopted. However, only two channels (FP1, FP2) are used to this study considering the applicability of the proposed method in real enveironment, and to compare it with the commercial 2 channel EEG device. Frequency domain features are power of each frequency bands, subtraction, addition, or division by each frequency bands. Features in time domain are hurst exponent, correlation dimension, lyapunov exponent, etc. Total 6 subjects are participated in this experiment with English sentence reading task given. Among several candidate features, ${\frac{{\theta}\;power}{mid\;{\beta}\;power}}$ shows the best test performance (70.8%). For future work, we will confirm the results is consistent in low price EEG device.

HF-Band Magnetic-Field Communication System Using Bias Switching Circuit of Class E Amplifier (E급 증폭기의 바이어스 스위칭 회로를 이용한 HF-대역 자기장 통신 시스템)

  • Son, Yong-Ho;Lee, June;Cho, Sang-Ho;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1087-1093
    • /
    • 2012
  • In this paper, we implemented a HF-band magnetic-field communication system consisting of an amplitude shift keying(ASK) transmitter, a pair of loop antennas, and an ASK receiver. Especially, we suggested a new ASK transmitter architecture, where a drain bias of class E amplifier is switched alternatively between two voltage levels with respect to input data. A maximum 5 W class E amplifier was designed using a low cost IRF510 power MOSFET at the frequency of 6.78 MHz. A measured sensitivity of the designed ASK receiver is -78 dBm, which consists of a log amplifier, a filter, and a comparator. Maximum communication range of magnetic-wave communication system with loop antennas was calculated using magnetic field equations in both near-field and far-field ranges. Also, in order to verify the calculated values, an indoor propagation loss was measured using a pair of loop antennas whose dimensions are $30{\times}30cm$. Maximum operating range is estimated about 35 m in case of transmitter's output power of 1 W and receiver sensitivity of -70 dBm, respectively. Finally, the communication field test using the designed ASK transmitter and receiver was successfully done at the distance of 5 m.

Design of logic process based 256-bit EEPROM IP for RFID Tag Chips and Its Measurements (RFID 태그 칩용 로직 공정 기반 256bit EEPROM IP 설계 및 측정)

  • Kim, Kwang-Il;Jin, Li-Yan;Jeon, Hwang-Gon;Kim, Ki-Jong;Lee, Jae-Hyung;Kim, Tae-Hoon;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.8
    • /
    • pp.1868-1876
    • /
    • 2010
  • In this paper, we design a 256-bit EEPROM IP using only logic process-based devices. We propose EEPROM core circuits, a control gate (CG) and a tunnel gate (TG) driving circuit, to limit the voltages between the devices within 5.5V; and we propose DC-DC converters : VPP (=+4.75V), VNN (-4.75V), and VNNL (=VNN/3) generation circuit. In addition, we propose switching powers, CG_HV, CG_LV, TG_HV, TG_LV, VNNL_CG, VNNL_TG switching circuit, to be supplied for the CG and TG driving circuit. Simulation results under the typical simulation condition show that the power consumptions in the read, erase, and program mode are $12.86{\mu}W$, $22.52{\mu}W$, and $22.58{\mu}W$ respectively. Furthermore, the manufactured test chip operated normally and generated its target voltages of VPP, VNN, and VNNL as 4.69V, -4.74V, and -1.89V.

Study of Serious Bacterial Infections in Febrile Infants Younger than Three Months of Age (열이 있는 3개월 이하의 영아에서 세균성 감염의 예측에 대한 연구)

  • Jeon, Myeoung Won;Lee, Ji Young;Jang, Young Taek
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.2
    • /
    • pp.215-222
    • /
    • 2003
  • Purpose : This study was to analyze serious bacterial infections in infants younger than three months of age and to review the direction of treatments for these patients. Methods : 378 febrile infants with a rectal temperature ${\geq}38.0^{\circ}C$ visited from Jan. 2001 through Dec. 2002 were retrospectively studied. Infants with the following criteria belonged to the low risk group. WBC $5,000{\sim}15,000/mm^3$, WBC negative in urine stick test and negative for nitirite test, CSF WBC < $10/mm^3$ and negative in CSF gram stain, negative chest X-ray, stool WBC <5/HFP(high power field), and focal infection. If any of the above criteria were not met, they belonged to the high risk group. SBI was defined as a positive culture of urine, blood or CSF. SI was defined as aseptic meningitis or pneumonia including above laboratory tests of SBI. SBI patients were separately compared with two groups, high risk and low risk. Results : Of the 378 infants that were tested 216(57.1%) were in the high risk group and 162(42.9%) in the low risk group. Among 105 SBI(27.8%) and 172 SI(45.5%), there were 98 urinary tract infection(25.2%), 10 bacteremia(2.6%), 2 bacterial meningitis(0.6%), and 77 aseptic meningitis(22.8%). There were 76 SBI(35.2%) from the high risk group and 29 SBI(17.9%) from the low risk group identified. The results of the sensitivity(72.4%), the specificity(48.7%), the negative predictive value(82.1%) and the positive predictive value (35.2%) were calculated. Conclusion : Even though the probability of SBI in the low risk group is insignificant, it should still be considered in febrile infants younger than 3 months of age. I believe the CSF study is necessary because of the moderate high incidence of abnormal finding in our study.

  • PDF

Biological effects of a semiconductor diode laser on human periodontal ligament fibroblasts

  • Choi, Eun-Jeong;Yim, Ju-Young;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.3
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: It has been reported that low-level semiconductor diode lasers could enhance the wound healing process. The periodontal ligament is crucial for maintaining the tooth and surrounding tissues in periodontal wound healing. While low-level semiconductor diode lasers have been used in low-level laser therapy, there have been few reports on their effects on periodontal ligament fibroblasts (PDLFs). We performed this study to investigate the biological effects of semiconductor diode lasers on human PDLFs. Methods: Human PDLFs were cultured and irradiated with a gallium-aluminum-arsenate (GaAlAs) semiconductor diode laser of which the wavelength was 810 nm. The power output was fixed at 500 mW in the continuous wave mode with various energy fluencies, which were 1.97, 3.94, and 5.91 $J/cm^2$. A culture of PDLFs without laser irradiation was regarded as a control. Then, cells were additionally incubated in 72 hours for MTS assay and an alkaline phosphatase (ALPase) activity test. At 48 hours post-laser irradiation, western blot analysis was performed to determine extracellular signal-regulated kinase (ERK) activity. ANOVA was used to assess the significance level of the differences among groups (P<0.05). Results: At all energy fluencies of laser irradiation, PDLFs proliferation gradually increased for 72 hours without any significant differences compared with the control over the entire period taken together. However, an increment of cell proliferation significantly greater than in the control occurred between 24 and 48 hours at laser irradiation settings of 1.97 and 3.94 $J/cm^2$ (P<0.05). The highest ALPase activity was found at 48 and 72 hours post-laser irradiation with 3.94 $J/cm^2$ energy fluency (P<0.05). The phosphorylated ERK level was more prominent at 3.94 $J/cm^2$ energy fluency than in the control. Conclusions: The present study demonstrated that the GaAlAs semiconductor diode laser promoted proliferation and differentiation of human PDLFs.

Extension of Low Temperature Combustion Regime by Turbocharging Using Diesel and Biodiesel Fuels (과급에 의한 디젤 및 바이오디젤의 저온연소 운전영역 확장에 관한 연구)

  • Jang, Jae-Hoon;Oh, Seung-Mook;Lee, Yong-Gyu;Lee, Sun-Youp
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1065-1072
    • /
    • 2012
  • Due to its oxygen (O) content, biodiesel (BD) is advantageous in that it lowers PM emissions in CI engines. Therefore, BD is considered one of the best candidates for low temperature combustion (LTC) operation because its use can extend the regime for simultaneous reduction of PM and $NO_x$. Thus, in this study, LTC operation was realized using BD and diesel with a 5~7% $O_2$ fraction. Engine test results show that the use of BD increased the efficiency and reduced emissions such as PM, THC, and CO; furthermore, IMEP reduced by 10~12% owing to the lower LHV of the fuel. In particular, smoke was suppressed by up to 90% because O atoms in the BD enhanced the soot oxidation reaction. To compensate the IMEP loss, turbocharging (TC) was then tested, and the results showed that the power output increased and PM was reduced further. Moreover, TC in BD engine operation allowed a similar level of reduction in both $NO_x$ and PM at 11~12% $O_2$ fraction, suggesting that there is a potential to widen the operating range by the combination of TC and BD.

The Study on the On-line Sales Fitness of Small-sized Companies' Product Categories by the Integration of SEC and FCB Framework (SEC와 FCB골격 의 통합적 접근방법을 통한 중소기업 제품군의 인터넷 판매 적합성에 대한 연구)

  • Park, Seong-Yong
    • Journal of Global Scholars of Marketing Science
    • /
    • v.16 no.3
    • /
    • pp.169-189
    • /
    • 2006
  • The product categories that can be sold on-line are expanding. It is interesting to see which product categories have more sales possibilities on internet. Small-sized firms' products have low distribution coverage, low brand recognition, bigger dispersion in the perception on the values which consist of quality vs. price, and higher possibilities of perceived purchase risks. Since on-line shopping is supposed to provide opportunities to small-sized firms that have low distribution and brand power, it is quite necessary to evaluate the fitness of on-line sales for small-sized firms' product categories. There are virtually no research studies on the on-line sales for small-sized firms' product categories. In this study, based on the integration of SEC, FCB, and related concepts, we develop new theoretical framework and test the fitness of on-line sales for small-sized firms' product categories by conducting empirical analysis. The empirical results on 17 product categories show that SEC, FCB, purchase risks, brand factors are somewhat related. Unlike previous studies, since the fitness of SEC and on-line sales are not clearly shown, we need to consider those problems within inter-related multiple frameworks. That is, it is necessary to evaluate the fitness of on-line sales after defining the product categories within the integrated multiple frameworks rather than within the single framework.

  • PDF

Static Fluid-Structure Coupled Analysis of Low-Pressure Final-Stage Turbine Blade (발전용 저압터빈 최종단 블레이드의 정적 유체-구조 연계해석)

  • Kwon, Sun-Guk;Lee, Young-Shin;Bae, Yong-Chae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1067-1074
    • /
    • 2010
  • In this study, a loosely coupled fluid-structure interaction (FSI) analysis was conducted for a low-pressure (LP) final-stage rotor blade. Preliminary FSI analyses of a $15^{\circ}$ sweptback wing and a NASA Rotor 37 compressor blade were performed for verifying the boundary conditions. The results were compared with the established literatures for each model. The FSI analysis of the $15^{\circ}$ sweptback wing was carried out under both stable and unstable conditions. The excessive deformation of the wing was observed within 0.05 s under the unstable condition which is higher than the divergence speed of a wing compared with the stable condition. On the basis of the results of a steady-state study, an unsteady state FSI analysis was conducted for a NASA Rotor 37. Different deformations were observed at trailing edge of the blade in the static FSI and dynamic FSI analysis. A 3D FE model of a LP rotor was generated from the span-wise section data. In order to develop a reasonable model, an impact test was performed and compared to the FE model. Using this FE model, the steady-state FSI analysis was performed successfully.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Changes in the Texture and Salt Content of Chinese Cabbage Using Different Salting Methods (절임 방법에 따른 배추 조직 및 염도 변화)

  • Lee, Myung-Ki;Yang, Hye-Jung;Woo, Ha-Na;Rhee, Young-Kyoung;Moon, Sung-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1184-1188
    • /
    • 2011
  • This study analyzed changes in the texture and salt content of Chinese cabbage after salting using different methods to determine the effects of low salt brining. To verify the possibility of brining under low salt concentration, Chinese cabbage was salted with 1%, 2%, 6%, and 10% salt solutions by pressing, pressure reduction, or steaming. After salting, the firmness (g, determined using the puncture test) of the Chinese cabbage changed according to the brining methods used, however, an increasing trend in rigidity was observed as the salinity increased. Because the power applied during pressing or pressure reduction treatments is higher, the firmness of and penetration time on the surface of the brined Chinese cabbages after these treatments increased more in the 6% salt solution cabbage. Additionally, the Chinese cabbages treated with steam showed significantly higher firmness and penetration time than those treated by pressing and pressure reduction. As a result of pressing the 6% salt concentrated cabbage with 1.35 $kg{\cdot}f/cm^2$, a pressure reduction from 250 mmHg, and steaming at 100$^{\circ}C$ for 1 min, the cabbage had roughly 2% of the salt concentration, ultimately. These physical treatments of pressing, pressure reduction, and steaming could be used as new methods for preparing salted Chinese cabbage with low salt concentrations for general use.