• Title/Summary/Keyword: Low Power Test

Search Result 1,422, Processing Time 0.028 seconds

An Experimental Study of the Fuel Additive to Improve the Performance of a 2-Stroke Large Diesel Engine (2행정 대형 디젤엔진의 성능향상을 위한 연료첨가제의 실험적 연구)

  • Ryu, Younghyun;Lee, Youngseo;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.620-625
    • /
    • 2015
  • In an effort to reduce the onset of global warming, the International Maritime Organization Marine Environment Protection Committee (IMO MEPC) proposed the reduction in ship speeds as a way of lowering the proportion of carbon dioxide ($CO_2$) in the Green House Gas emissions from ships. To minimize fuel costs, shipping companies have already been performing slow steaming for their own fleets. Specifically, the slow steaming approach has been adopted for most ocean-going container lines. In addition, because of the increased marine fuel cost that is required to enable increased capacity, there is an urgent need for more advanced fuel-saving technologies. Therefore, in this present study, we propose a fuel-cost reduction method that can improve the performance of diesel engines. We introduce a predetermined amount (0.025% of the amount of fuel used) of fuel additive (oil-soluble calcium-based organometallic compound). For improved experimental accuracy, as the test subjects, we utilize a large two-stroke diesel engine installed in land plants. The loads of the test engine were classified as low, medium, and high (50, 75, and 100%, respectively). We compare the engine performance parameters (power output, fuel consumption rate, p-max, and exhaust temperature) before and after the addition of fuel additives. Our experimental results, confirmed that we can realize fuel-cost savings of at least 2% by adding the fuel additive in low load conditions (50%). Likewise, the maximum combustion pressure was found to have increased. On the other hand, we observed that there was a reduction in the exhaust temperature.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

The availability for cardiorespiratory fitness measurement by 20 m shuttle run test in different sports type of elite athletes. Exercise Science (엘리트 선수들의 운동특성에 따른 20 m 셔틀런 검사의 유용성)

  • Kim, J.K.;Lee, N.J.;Lee, M.S.
    • Exercise Science
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • This study is to evaluate the availability of cardiorespiratory fitness measurement by 20 m shuttle run test based upon energy contribution rates of elite athletes in different sports type. Sixty-seven elite athletes attending K national university participated in this study. They were divided by three groups based upon sports type, composed of Anaerobic Group (sprint, jumps, weightlifting, throw; n=35), Aerobic Group (medium-long distance; n=9), and Combat Sport Group (judo; n=23). 20 m shuttle run test was conducted by Leger et al.(1982) method and calculating acceleration using measured shuttle run repetitions was conducted by Brewer et al.(1988) method. To test the usefulness of VO2max, graded exercise treadmill test was conducted and standing long jump and 50 m run were measured as power fitness factors. Z-jump was used for measuring power, agility, and muscular endurance. Standing long jump and 50 m run of Anaerobic Group (AnG) was significantly higher than that of Aerobic Group (AeG) and Combat Sport Group (CG) (p<0.05). However, Z-jump of CG was significantly higher than that of AnG and AeG(p<.05). There was a higher correlation of 20 m shuttle run test and VO2max in AnG(r= 0.577, p<.0001) and CG(r= 0.760, p<.0001). Otherwise, there was a low correlation of 20 m shuttle run test and VO2max in AeG. There was no significant group difference to test the availability of 20 m shuttle run test and there was a reduced error when converting 20 m shuttle run results into VO2max. This study examined the usefulness of 20 m shuttle run test by converting 20 m shuttle run repetition results into VO2max calculation, which showed reduced error. Therefore, this study confirmed that it would be needed to convert 20 m shuttle run results into VO2max for universal and practical use in the field without dividing sports type.

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Study on the procedure to obtain an attainable speed in pack ice

  • Kim, Hyun Soo;Jeong, Seong-Yeob;Woo, Sun-Hong;Han, Donghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.491-498
    • /
    • 2018
  • The cost evaluation for voyage route planning in an ice-covered sea is one of the major topics among ship owners. Information of the ice properties, such as ice type, concentration of ice, ice thickness, strength of ice, and speed-power relation under ice conditions are important for determining the optimal route in ice and low operational cost perspective. To determine achievable speed at any designated pack ice condition, a model test of resistance, self-propulsion, and overload test in ice and ice-free water were carried out in a KRISO ice tank and towing tank. The available net thrust for ice and an estimation of the ice resistance under any pack ice condition were also performed by I-RES. The in-house code called 'I-RES', which is an ice resistance estimation tool that applies an empirical formula, was modified for the pack ice module in this study. Careful observations of underwater videos of the ice model test made it possible to understand the physical phenomena of underneath of the hull bottom surface and determine the coverage of buoyancy. The clearing resistance of ice can be calculated by subtracting the buoyance and open water resistance form the pre-sawn ice resistance. The model test results in pack ice were compared with the calculation results to obtain a correlation factor among the pack ice resistance, ice concentration, and ship speed. The resulting correlation factors were applied to the calculation results to determine the pack ice resistance under any pack ice condition. The pack ice resistance under the arbitrary pack ice condition could be estimated because software I-RES could control all the ice properties. The available net thrust in ice, which is the over thrust that overcomes the pack ice resistance, will change the speed of a ship according to the bollard pull test results and thruster characteristics (engine & propulsion combination). The attainable speed at a certain ice concentration of pack ice was determined using the interpolation method. This paper reports a procedure to determine the attainable speed in pack ice and the sample calculation using the Araon vessel was performed to confirm the entire process. A more detailed description of the determination of the attainable speed is described. The attainable speed in 1.0 m, 90% pack ice and 540 kPa strength was 13.3 knots.

Engineering Characteristics of Liquid Filler Using Marine Clay and In-situ Soil (해양점토와 현장토를 활용한 유동성 채움재의 공학적 특성)

  • Oh, Sewook;Bang, Seongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.9
    • /
    • pp.25-32
    • /
    • 2020
  • The underground utilities installed under the ground is an important civil engineering structure, such as water supply and sewerage pipes, underground power lines, various communication lines, and city gas pipes. Such underground utilities can be exposed to risk due to external factors such as concentrated rainfall and vehicle load, and it is important to select and construct an appropriate backfill material. Currently, a method mainly used is to fill the soil around the underground utilities and compact it. But it is difficult to compact the lower part of the buried pipe and the compaction efficiency decreases, reducing the stability of the underground utilities and causing various damages. In addition, there are disadvantages such as a decrease in ground strength due to disturbance of the ground, a complicated construction process, and construction costs increase because the construction period becomes longer, and civil complaints due to traffic restrictions. One way to solve this problem is to use a liquid filler. The liquid filler has advantages such as self-leveling ability, self-compaction, fluidity, artificial strength control, and low strength that can be re-excavated for maintenance. In this study, uniaxial compression strength test and fluidity test were performed to characterize the mixed soil using marine clay, stabilizer, and in-situ soil as backfill material. A freezing-thawing test was performed to understand the strength characteristics of the liquid filler by freezing, and in order to examine the effect of the filling materials on the corrosion of the underground pipe, an electrical resistivity test and a pH test were performed.

Field Test and Performance Verification of On-board Oriented Train Control System (차상중심 열차제어시스템의 현장시험을 통한 성능검증)

  • Baek, Jong-Hyen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5513-5521
    • /
    • 2015
  • There is an operational efficiency problem about wayside equipment applied to the domestic low-density branch as the equipment has been installed and operated similarly in the mainline. On-board oriented train control system, which has been developed for train safety and operation efficiency, ensures safe train operation without expensive ground control signal devices. Such system consists of on-board control system, wayside control system, and local control system. In this paper, the details of tests such as suitability test, communication test, and interface test are described by installing the on-board control system and wayside control system in field. Installation tests include checking power, voltage, cable connection, LED status, etc. Field applicability of the developed system is also verified through the dynamic operation tests with diverse scenarios, which are performed on the virtual line similar to the real environment including switch machine and level crossing gate. Dynamic operation tests were conducted for total 7 scenarios, and several tests were repeated for each scenario. The elapsed time for each operation was computed by analyzing main process log, and we could check that each operation was accomplished within several seconds. Furthermore, the developed system was verified through field test with an accredited institute, and testing certificates were issued.

A Comparative Study on the Ametropias of Philippines and Koreans (한국인과 필리핀인의 굴절이상에 대한 연구)

  • Lee, Hark-Jun;Kwen, Man-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.477-482
    • /
    • 2012
  • Purpose: This study is aimed at finding the conditions of ametropia of adults in the Philippines and the South Korean. Methods: The study objects were 7,695(15,390 eyes) Koreans and 2,256(4,512 eyes) Philippines who visited optic clinics and took refraction test. The distributions of their hypermetropias and myopias about astigmatisms were examined, using the method of equivalent spherical power. When astigmatisms were marked in S-C, cylinder lens diopter and astigmatism axis, presbyopic additions and pupillary distances were analyzed by comparison respectively. Results: Among ametropias of Koreans myopias and hypermetropias were 93.69% and 6.31% respectively and about ametropias of Philippines myopia and hypermetropias were 73.43% and 26.57% respectively. As for spherical equivalent power about Koreans, the results showed that Koreans marked -3.352 D about myopia and Philippines marked -2.213 D about it. There is a gap of -1.139 D between them. About hypermetropia Koreans marked 1.147 D and Philippines, 1.251 D and their gap is 0.104 D. As for ametropia of Koreans there is 49.86% in middle myopia, 32.28% about low myopia, 11.55% about high myopia, and 5.54% about low hypermetropia, 0.75% about middle hypermetropia. As for it about Philippines there is 44.53% in low myopia, 25.11% about middle myopia, 3.79% high myopia and 23.03% low hypermetropia, and 3.51% low hypermetropia respectively. As for cylinder lens there is differences of 0.194 D and 0.22 D between Korean and Philippine for both sexes. Totally Koreans have higher cylinders of 0.175 D than Philippines. As for astigmatism, Koreans have direct astigmatism, inverse astigmatism, and oblique astigmatism in their suffering sequence. As for Philippines, they have direct astigmatism, inverse stigmatism, and oblique astigmatism in their abnormal sequence, and they have higher oblique stigmatism than Koreans. As for presbyopic addition, Philippines have higher distributions than Koreans, and 0.296 D is higher in average. As for pupillary distance, Koreans have longer distance of 0.97 mm in man and 0.63 mm in women than Philippines. Conclusions: As for ametropia, Koreans and Philippines have more myopias than hypermetropias, but Philippines have more rates of hypermetropias than Koreans. And Philippines have more presbyopic additions. Koreans have higher morbidity of inverse astigmatism, and Philippines have higher morbidity of oblique astigmatism comparatively. As for pupillary distance, Koreans have longer length in the body characteristics. This shows that geographical circumstances have much to do with refraction conditions of eyes.

Design of Low-Area 1-kb PMOS Antifuse-Type OTP IP (저면적 1-kb PMOS Antifuse-Type OTP IP 설계)

  • Lee, Cheon-Hyo;Jang, Ji-Hye;Kang, Min-Cheol;Lee, Byung-June;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1858-1864
    • /
    • 2009
  • In this paper, we design a non-volatile memory IP, 1-kb one-time programmable (OTP) memory, used for power management ICs. Since a conventional OTP cell uses an isolated NMOS transistor as an antifuse, there is an advantage of it big cell size with the BCD process. We use, therefore, a PMOS transistor as an antifuse in lieu of the isolated NMOS transistor and minimize the cell size by optimizing the size of a OTP cell transistor. And we add an ESD protection circuit to the OTP core circuit to prevent an arbitrary cell from being programmed by a high voltage between the terminals of the PMOS antifuse when the ESD test is done. Furthermore, we propose a method of turning on a PMOS pull-up transistor of high impedance to eliminate a gate coupling noise in reading a non-programmed cell. The layout size of the designed 1-kb PMOS-type antifuse OTP IP with Dongbu's $0.18{\mu}m$ BCD is $129.93{\times}452.26{\mu}m^2$.

The Effect of Sputtering Process Variables on the Properties of Pd Alloy Hydrogen Separation Membranes (스퍼터 공정변수가 팔라듐 합금 수소분리막의 특성에 미치는 영향)

  • Han, Jae-Yun;Joo, Sae-Rom;Lee, Jun-Hyong;Park, Dong-Gun;Kim, Dong-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.6
    • /
    • pp.248-257
    • /
    • 2013
  • It is generally recognized that thin Pd-Cu alloy films fabricated by sputtering show a wide range of microstructures and properties, both of which are highly dependent on the sputtering conditions. In view of this, the present study aims to investigate the relationship between the performance of hydrogen separation membranes and the microstructure of Pd alloy films depending on sputtering deposition conditions such as substrate temperature, working pressure, and DC power. We fabricated thin and dense Pd-Cu alloy membranes by the micro-polishing of porous Ni support, an advanced Pd-Cu sputtered multi-deposition under the conditions of high substrate temperature / low working pressure / high DC power, and a followed by Cu-reflow heat-treatment. The result of a hydrogen permeation test indicated that the selectivity for $H_2/N_2$ was infinite because of the void-free and dense surface of the Pd alloy membranes, and the hydrogen permeability was 10.5 $ml{\cdot}cm^{-2}{\cdot}min^{-1}{\cdot}atm^{-1}$ for a 6 ${\mu}m$ membrane thickness.