• Title/Summary/Keyword: Low Power Operation

Search Result 1,994, Processing Time 0.033 seconds

Deep Learning Based Electricity Demand Prediction and Power Grid Operation according to Urbanization Rate and Industrial Differences (도시화율 및 산업 구성 차이에 따른 딥러닝 기반 전력 수요 변동 예측 및 전력망 운영)

  • KIM, KAYOUNG;LEE, SANGHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.5
    • /
    • pp.591-597
    • /
    • 2022
  • Recently, technologies for efficient power grid operation have become important due to climate change. For this reason, predicting power demand using deep learning is being considered, and it is necessary to understand the influence of characteristics of each region, industrial structure, and climate. This study analyzed the power demand of New Jersey in US, with a high urbanization rate and a large service industry, and West Virginia in US, a low urbanization rate and a large coal, energy, and chemical industries. Using recurrent neural network algorithm, the power demand from January 2020 to August 2022 was learned, and the daily and weekly power demand was predicted. In addition, the power grid operation based on the power demand forecast was discussed. Unlike previous studies that have focused on the deep learning algorithm itself, this study analyzes the regional power demand characteristics and deep learning algorithm application, and power grid operation strategy.

Study on DAS-Based Time Synchronization for Improving Reliability of Section Load Estimation

  • Lee, In-tae;Lee, Ji-Hoon;Jung, Nam-Joon;Jung, Young-Beom;Lee, Byung-sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • For effective distribution planning and operation, we need a reliable estimation of operation capacity. But it is difficult to ensure reliability due to the low accuracy of section load data, which is used as a basis in estimating the operation capacity. This paper discusses how to improve the accuracy of section load data by analyzing the existing method of estimating the section load, using statistical techniques to adjust the acquired data, and using the section load estimation algorithm to estimate the section load based on the adjusted data.

The Study on Parallel operation of IGBT for the Medium SE the Large capacity Inverter ($\cdot$ 대용량 인버터용 IGBT 병렬 운전 연구)

  • Park G.T.;Yoon J.H.;Jung M.K.;Kim D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.430-433
    • /
    • 2003
  • IGBTS are widely used for the industrial inverters in the mid power range at low voltage (440V$\~$660V) application. Advantageous features of the device are simple gate drive and high speed switching capability. Due to these advantages the application of IGBTS is enlarging into the high power application. However, to increase the power handling capacity at lower input voltage level, the current rating in each bridge arm must be enlarged. Therefore the parallel operation of IGBT devices is essentially needed. This paper describes the feasible parallel structures of the power circuit for the mid & the high power inverters and introduces the important design condition for the parallel operation of IGBT devices. To verify feasibility of the IGBT parallel operation, the feature of several IGBT devices (EUPEC, SEMIKRON's IGBT) are investigated and the power stacks are implemented and tested with these devices. The experimental results show the good characteristics for the parallel operation of IGBTS.

  • PDF

Integrated High-Voltage Generators for Low-Power Bistable LCD Drivers

  • Doutreloigne, Jan;Hendrix, Wim
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.135-138
    • /
    • 2004
  • This paper describes the architecture, the basic operation principle and detailed experimental results of digitally programmable high-voltage generators that can be used in monolithic low-power high-voltage bistable LCD drivers. Two different design approaches, depending on whether the application allows the use of external passive components or not, are analyzed.

  • PDF

Design of Power Supply for Green PC using Low Voltage High Current LLC Resonant Converter (저전압 대전류 LLC 공진형 컨버터를 이용한 그린 PC용 전원공급장치 설계)

  • Yoo, Young-Do;Kim, In-Dong;Nho, Eui-Cheol;Ryu, Myung-Hyo;Baek, Ju-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • This paper proposes a low voltage high current LLC resonant converter for Green PC. Green PC is composed of a lot of blade PCs, and it is a centralized system to manage them in computer center. Green PC should require that its power supplies have several characteristics such as low output voltage, high output current, and high power conversion efficiency. Conventional PSFB (Phase Shift Full Bridge) converter is usually used as DC/DC converter for computer power supply because it has high power conversion efficiency thanks to ZVS (Zero Voltage Switching) operation under middle and high load conditions. However, this converter has some problems such as large switching noise and limitation of ZVS operation under light load condition. In order to improve the performance of power supply for Green PC, a new power supply using popular high efficiency LLC resonant converter for low voltage and high current application is proposed in this paper. The proposed power supply has ZVS capability over the entire load range, thus resulting in good efficiency and high switching frequency. Experimental results verify the performance of the proposed power supply for Green PC using 2[kW] (19[V], 105[A]) rated prototype converter.

Development of Low Power Driven Inner Tap Inspection System capable of Wireless Communication with Video Equipment (영상기기와 무선통신이 가능한 저전력 구동의 이너탭 검사시스템 개발)

  • Ahn, Sung-Su
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.649-658
    • /
    • 2018
  • In this paper, we propose a mechanical contact inner tap inspection system that can inspect the defect of the inner tap immediately after inner tap is processed within the machining center. The inspection module has the collet chuck structure, so it can mounted on the main spindle of the machining center during inspection. It was developed with a focus on inspection for tap having 20 mm depth which is primarily fabricated in automotive parts and has a double sided PCB-type control system including sensing function based on Zigbee module, micom and IR sensor for wireless transmission of measured data with low power operation, and also a battery for supplying electric power. The current consumption is 46.8mA in the inspection operation mode and 0.0268mA in the power saving mode for 3.7V of the applied power source, so that 30,000 times or more inspection can be performed with assumed 5 seconds inspection time for one tap. Experiments in test jig system and actual machining center confirm that the proposed inner tap inspection system can be applied to the batch process of simultaneous inspection after tapping in the machining center.

Advanced Field Weakening Control for Maximum Output Power Operation of Seawater Cooling Pump Induction Motor in a Limited Environment (제한된 환경에서의 해수냉각펌프용 유도전동기 최대출력 운전을 위한 약계자 제어)

  • Son, Yung-Deug;Seo, Yong-Joo;Jung, Jun-Hyung;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.540-546
    • /
    • 2013
  • The induction motor is used for driving the special equipments such as warship and submarine pump due to robust structure and simple maintenance. Domestic and foreign warships use a wide range of voltages and the DC voltage sources mainly from battery. In the low voltage level, the ${\Delta}$-connection operation of induction motor can be used for the maximum power. However, the temperature of the inverter increases because of the high input current. On the other hand, Y-connection operation of the induction motor does not cause a problem of temperature because of the low input current compared to the ${\Delta}$-connection. But the lack of the supply voltage can not be avoided. Therefore, this paper suggests the algorithm of the optimum field weakening control to extend the operating range of the induction motor with maximum power in a limited thermal and DC voltage condition.

A Study on Variable Speed Generation System with Energy Saving Function

  • Dugarjav, Bayasgalan;Lee, Sang-Ho;Han, Dong-Hwa;Lee, Young-Jin;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.137-143
    • /
    • 2013
  • This paper presents development of variable speed generation (VSG) system with energy saving function. The rubber tyred gantry crane (RTGC) requires the power from diesel-engine. Significant fuel savings by reducing the engine speed can be achieved, because all of operation modes except hoisting are required lower power than rated value of engine. When low speed operation output voltage of generator is decrease until acceptable range of motor driver inverters and auxiliary load supplier. According to power demand engine speed is varying from 20 to 60Hz, and voltage is varying between 210Vac and 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control and inverters dc site voltage is compensated by it. This paper proposed 3-phase interleaved boost converter which has the same structure as the commercially available 3-phase inverter and current sharing capability. 400kW interleaved converter is designed and a performance of converter is evaluated through several experiments with a RTGC system. Energy saving VSG system can cut down fuel consumption by 36% and 21.3% at idle and unidirectional load operations.

A Control Method of Distributed Generation System Which is Connected to Power Distribution System : Without LDC Operation (배전계통에서의 분산전원 도입운용 관리방법 : LDC 운전을 하지 않을 경우)

  • Jung, Won-Jae;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.231-233
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers. So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper computes permissible operation limit of DGS when the DGS is connected to power distribution system using fixed tap(without LDC operation). For this simulation, KEPCO distribution system is used.

  • PDF

Design and Implementation of Standby Power Control Module based on Low Power Active RFID (저 전력 능동형 RFID 기반 대기 전력 제어 모듈 설계 및 구현)

  • Jang, Ji-Woong;Lee, Kyung-Hoon;Kim, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.491-497
    • /
    • 2015
  • In this paper a method of design and Implementation of RFID based control system for reducing standby power consumption at the power outlet is described. The system is composed of a RF controlled power outlet having relay and an active RFID tag communicating with the RF reader module controlling the relay. When the tag carried by human approaches to the RF reader the reader recognizes the tag and switch off the relay based on the RSSI level measurement. A low power packet prediction algorithm has been used to decrease the DC power consumption at both the tag and the RF reader. The result of experiment shows that successful operation of the relay control has been obtained while low power operation of the tag and the reader is achieved using above algorithm. Also setting the distance between the reader and the tag by controlling transmission power of the tag and adjusting the duty cycle of the packet waiting time when the reader is in idle state allows us to reduce DC power consumption at both the reader and the tag.