• 제목/요약/키워드: Low Power Operation

검색결과 1,994건 처리시간 0.031초

Induction Motor with Adjustable Windings for High Efficiency Drive in Light Load Operation

  • Zhang, Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.508-513
    • /
    • 2014
  • Heavy load start but light load operation is a common case in practical drive applications. When an induction motor is employed for such applications, its rated power is usually chosen according to the heavy load start. Then, during light load operation, its efficiency and power factor are low. To solve this problem, it is proposed to adjust the motor windings from the startup to the normal operation conditions. In this paper, arrangement of the adjustable windings is introduced, air gap field with different windings is investigated, and steady state operation performance under various loads is examined. It can be seen that by using proper winding arrangement both startup and operation performances are satisfactory.

아날로그 히스테리시스 전류 제어기를 적용한 3상 PWM 컨버터 개발 (Development of 3 Phase PWM Converter using Analog Hysteresis Current Controller)

  • 이영국;노철원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.372-376
    • /
    • 2001
  • Due to several advantages of Pulse Width Modulation(PWM) Converter, such as unity power factor operation, elimination of low-order harmonics and regeneration of motor braking energy to source, the application range of PWM Converter has been rapidly extended in industrial application. Nowadays, vector control algorithm and space vector PWM(SVPWM) method are applied to improve the performances of PWM Converter, but vector control algorithm and SVPWM require to use Microprocessor and other digital devices in hardware, causing costly and somewhat large dimension system. In every practical application of energy conversion equipments, the design and implementation should be carried out considering cost and performance. High performance and low cost is the best choice for energy conversion equipments. So, this paper presents the practical design method and implementation results of 3-phase PWM Converter with analog hysteresis current controller, and verifies the performances of unit power factor operation and energy regeneration operation via experimental results.

  • PDF

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

저온도차 모형 스터링 엔진의 작동 해석 (Analysis of The Operation of a Low Temperature Differential Model Stilting Engine)

  • 김정국;심경용;정평석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.199-204
    • /
    • 2000
  • A low temperature differential model stirling engine is manufactured, and its operation characteristics are measured and analyzed by SIMPLE analysis model, in which heat transfer processes are simply considered. The heat transfer coefficients between working fluid and heat sources in the analysis are estimated by comparing the P-V diagrams by experiment and by analysis. This result may be very useful for further design and manufacture of model Stilting engines as well as real engines because it provides a comparatively correct predictions of the operation conditions and power output. It will be also conveniently used as an educational material for mechanical engineering students because it can be a nice example of optimal design process to decide the phase angle and compression ratio of engine design with a simple but realistic simulation.

  • PDF

고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터 (A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter)

  • 문상철;정봉근;구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

수용가 전력관리시스템 개발 연구 (A Study on the Development of Industrial Power Management System)

  • 문영환;성기철;윤상현;김언충
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.550-552
    • /
    • 1995
  • Real time informations from industrial power system in operation can be used for efficient energy conservation, optimal operation of electrical equipments, and expansion planning of apparatus. Requirements for energy conservation and supplied power quality in customers are increasing significantly because of their effects on the production cost and efficiency. Thus, the development of low cost power management system which can can operate in domestic power system properly is substantially requested. In this research, operation software for real time monitoring and control system in customer power system has been developed to achieve the above purposes. The development of the operating software and related technologies are expected to be applied successfully for reducing electricity cost, enhancing power quality, determining facility expansion planning, operating optimal power system, increasing production efficiency, and reducing maintenance cost.

  • PDF

Mutual Authentication Protocol Using a Low Power in the Ubiquitous Computing Environment

  • Cho Young-bok;Kim Dong-myung;Lee Sang-ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.91-94
    • /
    • 2004
  • Ubiquitous sensor network is to manage and collect information autonomously by communicating user around device. Security requirements in Ubiquitous based on sensor network are as follows: a location of sensor, a restriction of performance by low electric power, communication by broadcasting, etc. We propose new mutual authentication protocol using a low power of sensor node. This protocol solved a low power problem by reducing calculation overload of sensor node using two steps, RM(Register Manager) and AM(Authentication Manager). Many operations performing the sensor node itself have a big overload in low power node. Our protocol reduces the operation number from sensor node. Also it is mutual authentication protocol in Ubiquitous network, which satisfies mutual authentication, session key establishment, user and device authentication, MITM attack, confidentiality, integrity, and is safe the security enemy with solving low electric power problem.

  • PDF

감시정찰 센서네트워크에서 하드웨어 모듈의 소모전력 분석을 통한 저전력 노드 설계 전략 (Design Strategy of Low-Power Node by Analyzing the Hardware Modules in Surveillance and Reconnaissance Sensor Networks)

  • 김용현;여명호;정광수
    • 한국군사과학기술학회지
    • /
    • 제15권6호
    • /
    • pp.761-769
    • /
    • 2012
  • In this paper, we propose a low-power design strategy to minimize energy-consumption for surveillance and reconnaissance sensor networks. The sensor network consists of many different nodes with various operations such as target detection, packet relay, video monitoring, changing protocols, and etc. Each sensor node consists of sensing, computing, communication, and power components. These components are integrated on a single or multiple boards. Therefore, the power consumption of each component can be different on various operation types. First, we identified the list of components and measured power consumption for them from the first prototype nodes. Next, we focus on which components are the main sources of energy consumption. We propose many energy-efficient approaches to reduce energy consumption for each operation type.

저출력 레이저 조사가 성견의 실험적 치주질환 치유에 미치는 영향에 관한 조직병리학적 연구 (THE HEALING EFFECTS OF LOW POWER DENSITY LASER TO THE EXPERIMENTAL PERIODONTITIS;HISTOPATHOLOGIC STUDY)

  • 김동운;이재현;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제23권1호
    • /
    • pp.16-26
    • /
    • 1993
  • In order to investigate the healing effect on inflammation and bone regeneration of low power density laser radiation in dogs, experimental periodontitis was made in dog mandibular 3rd, 4th premolars. All teeth were classified with four groups of two experimental group and control groups. The second group were irradiated on periodontitis site and the first group were control. The fourth group were irradiated on periodontitis site flap operation and the third group were flap control. Experimental groups were irradiated with GaAs low power density laser of pulse wave and continuous wave of 904nm every day by five days respectively and then control group and experimental groups were evaluated by histo-pathological study. The results were as follows : 1. Experimental periodontits site of dog were irradiated with GaAs low power laser results in reducing of pseudoepitheliomatous proliferation and inflammation at light microscope. 2. After irradiation with low power density laser, experimental groups were revealed that PDL forming activity were increased and newly formed collagen deposition were observed. 3. Low power density lsaer irradiation on experimental periodontits site after flap operation showed that decreasing of inflammation, reducing of osteoclast activity. Capillary proliferation, reduction of pseudoepitheliomatous proliferation. 4. After irradiation with low power density laser on flap experimental site, experimental groups were revealed that newly formed collagen in periodontal ligament and alveolar bone were detected on MT staining.

  • PDF

적은 면적을 갖는 저전력, 고해상도 확장 개수 A/D 변환기 설계 (A Design of Low Power, High Resolution Extended-Counting A/D Converter with Small Chip Area)

  • 김정열;임신일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.47-50
    • /
    • 2002
  • An extended-counting analog to digital converter (ADC) is designed to have a high resolution(14bit) with low power consumption and small dia area. First order sigma-delta modulator with a simple counter for incremental operation eliminates the need of big decimation filter in conventional sigma-delta type ADC. To improve the accuracy and linearity, extended mode of successive approximation is followed. For 14-bit conversion operation, total 263 clocks(1 clock for reset, 256 clocks for incremental operation and extended 6 clocks for successive approximation operation) are needed with the sampling rate of 10 Ms/s This ADC is implemented in a 0.6um standard CMOS technology with a die area of 1 mm ${\times}$ 0.75 mm.

  • PDF