• 제목/요약/키워드: Low Power Operation

검색결과 1,991건 처리시간 0.028초

Low-temperature polycrystalline silicon level shifter using capacitive coupling for low-power operation

  • Chung, Hoon-Ju;Sin, Yong-Won;Cho, Bong-Rae
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.21-23
    • /
    • 2010
  • A new level shifter using low-temperature polycrystalline silicon (poly-Si) thin-film transistors (TFTs) for low-power applications is proposed. The proposed level shifter uses a capacitive-coupling effect and can reduce the power consumption owing to its no-short-circuit current. Its power saving over the conventional level shifter is 72% for a 3.3 V input and a 10 V output.

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권3호
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.

Single Sensor Charging System with MPPT Capability for Standalone Streetlight Applications

  • Osman, Siti Rahimah;Rahim, Nasrudin Abd.;Selvaraj, Jeyraj;Al-Turki, Yusuf A.
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.929-938
    • /
    • 2015
  • Maximum power point tracking (MPPT) and battery charging control are two important functions for a solar battery charger. The former improves utilization of the available solar energy, while the latter ensures a prolonged battery life. Nevertheless, complete implementation of both functions can be complex and costly, especially for low voltage application such as standalone street lamps. In this paper, the operation of a solar battery charger for standalone street light systems is investigated. Using only one voltage sensor, the solar charger is able to operate in both MPPT and constant voltage (CV) charging mode, hence providing high performance at a low cost. Using a lab prototype and a solar simulator, the operation of the charger system is demonstrated and its performance under varying irradiance is validated.

A Harmonic Circulation Current Reduction Method for Parallel Operation of UPS with a Three-Phase PWM Inverter

  • Kim Kyung-Hwan;Kim Wook-Dong;Hyun Dong-Suk
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.160-165
    • /
    • 2005
  • In a parallel operation of UPS, there are two types of circulating currents between UPS. One is the low order circulating current with a fundamental frequency caused by the amplitude and phase differences of UPS output voltages, and the other is the harmonic circulating current with PWM switching frequency caused by non-synchronized PWM waveforms among UPS. The elimination of the low order circulating current is essential for optimal load sharing in parallel operations of UPS, which can be accomplished by the phase and magnitude control at each UPS. The harmonic circulating current may cause troubles and deteriorate in performance of the controller for optimal load sharing in parallel operation of UPS. This paper presents a PWM synchronizing method to eliminate the harmonic circulation current in parallel operation of UPS. The effectiveness of the proposed scheme has been investigated and verified through experiments by a 50kVA UPS.

고출력 MHL용 구형저주파 구동 방식의 전자식 안정기 설계 (Electronic Ballast Design Driven by Low Frequency Square Wave for High Power MHL)

  • 김기남;박종연;최영민
    • 전력전자학회논문지
    • /
    • 제15권5호
    • /
    • pp.394-400
    • /
    • 2010
  • 본 논문에서는 Buck Converter 동작 원리를 Full -Bridge Inverter에 적용한 전자식 안정기를 제안하였다. 전자식안정기는 EMI 필터, 수동 PFC, Full-Bridge Inverter로 2-stage로 구성되어 있다. PFC는 신뢰성 확보를 위해 수동 PFC를 사용하였다. Full-Bridge Inverter는 High Side와 Low Side 스위치의 구동 주파수를 각각 고주파와 저주파로 구동하여 Buck Converter의 동작을 구현 하였다. 램프를 저주파수 구형파로 구동하여 음향공명현상을 피하게 되었으며, 고주파수 스위칭으로 인덕터의 부피를 줄였다. 제안한 방법은 시뮬레이션과 실험을 통해 증명하였다.

Dual Edge-Triggered NAND-Keeper Flip-Flop for High-Performance VLSI

  • Kim, Jae-Il;Kong, Bai-Sun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권2호
    • /
    • pp.102-106
    • /
    • 2003
  • This paper describes novel low-power high-speed flip-flop called dual edge-triggered NAND keeper flip-flop (DETNKFF). The flip-flop achieves substantial power reduction by incorporating dual edge-triggered operation and by eliminating redundant transitions. It also minimizes the data-to-output latency by reducing the height of transistor stack on the critical path. Moreover, DETNKFF allows negative setup time to provide useful attribute of soft clock edge by incorporating the pulse-triggered operation. The proposed flip-flop was designed using a $0.35{\;}\mutextrm{m}$ CMOS technology. The simulation results indicate that, for the typical input switching activity of 0.3, DETNKFF reduces power consumption by as much as 21 %. Latency is also improved by about 6 % as compared to the conventional flip-flop. The improvement of power-delay product is also as much as 25 %.

동기 스위치 제어를 통한 영전압 동작 고효율 능동 클램프 포워드 컨버터 (High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation)

  • 이성세;최성욱;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.266-268
    • /
    • 2005
  • A new synchronous switch controlled transient current build-up zero voltage switching (TCB-ZVS) forward converter is proposed. The proposed converter is suitable for the low-voltage and high-current applications. The features of the proposed converter are low conduction loss of magnetizing current, no additional circuit for the ZVS operation, high efficiency, high power density and low EMI noise throughout all load conditions.

  • PDF

25 kW급 전력사업용 MCFC 발전시스템 구성 및 운전평가 (Constitution and Operation of the 25 kW Molten Carbonate Fuel Cell Power Generation System for Power Utility)

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.687-689
    • /
    • 2000
  • Molten Carbonate Fuel Cell (MCFC) with high electrical efficiency and low environmental effect has been developed for the commercial application of power generation fields. Recently we have built a 25 kW molten carbonate fuel cell power generation system and tested it. The MCFC system is composed of diverse peripheral units such as reformer, pre-heater, water purifier. electrical loader, gas supplier, and recycling systems. The stack itself was made of 40 cells of $6.000 cm^2$ area each. The stack showed an output of 28.6 kW power and a reliable performance at atmospheric operation. while in pressurized operation the stack showed an output 25.6 kW lower than the atmospheric operation. The reason of lower performance of pressurized operation was caused from a gas cross over shown in few cells in the stack.

  • PDF

토템폴 브리지리스 PFC에서 동기정류 스위치의 효율 영향에 관한 연구 (A Study on Influence of Synchronous Rectification Switch on Efficiency in Totem Pole Bridgeless PFC)

  • 유정상;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.108-113
    • /
    • 2021
  • In this paper, a totem pole PFC was structured in two methods with FET and diode for low-speed switch while GaN FET was used for high-speed switch. Internal power loss, power conversion efficiency and steady-state characteristics of the two methods were compared in the totem pole bridgeless PFC circuit which is widely applied in large-capacity and high-efficiency switching rectifier of 500W or more. In order to compare and confirm the steady-state characteristics under equal conditions, a 2kW class totem pole bridgeless PFC was constructed and the experimental results were analyzed. From the experimental results, it was confirmed that the low-speed switch operation has a large difference in efficiency due to the internal conduction loss of the low-speed switch at a low input voltage. Especially, input power factor and load characteristic showed no difference regardless of the low-speed switch operation.

EVALUATION OF GALVANIC CORROSION BEHAVIOR OF SA-508 LOW ALLOY STEEL AND TYPE 309L STAINLESS STEEL CLADDING OF REACTOR PRESSURE VESSEL UNDER SIMULATED PRIMARY WATER ENVIRONMENT

  • Kim, Sung-Woo;Kim, Dong-Jin;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.773-780
    • /
    • 2012
  • The article presented is concerned with an evaluation of the corrosion behavior of SA-508 low alloy steel (LAS) and Type 309L stainless steel (SS) cladding of a reactor pressure vessel under the simulated primary water chemistry of a pressurized water reactor (PWR). The uniform corrosion and galvanic corrosion rates of SA-508 LAS and Type 309L SS were measured in three different control conditions: power operation, shutdown, and power operation followed by shutdown. In all conditions, the dissimilar metal coupling of SA-508 LAS and Type 309L SS exhibited higher corrosion rates than the SA-508 base metal itself due to severe galvanic corrosion near the cladding interface, while the corrosion of Type 309L in the primary water environment was minimal. The galvanic corrosion rate of the SA-508 LAS and Type 309L SS couple measured under the simulated power operation condition was much lower than that measured in the simulated shutdown condition due to the formation of magnetite on the metal surface in a reducing environment. Based on the experimental results, the corrosion rate of SA-508 LAS clad with Type 309L SS was estimated as a function of operating cycle simulated for a typical PWR.