• 제목/요약/키워드: Low Power Operation

검색결과 2,005건 처리시간 0.024초

저전력 소모와 테스트 용이성을 고려한 회로 설계 (A study on low power and design-for-testability technique of digital IC)

  • 이종원;손윤식;정정화;임인칠
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.875-878
    • /
    • 1998
  • In this thesis, we present efficient techniques to reduce the switching activity in a CMOS combinational logic network based on local logic transforms. But this techniques is not appropriate in the view of testability because of deteriorating the random pattern testability of a circuit. This thesis proposes a circuit design method having two operation modes. For the sake of power dissipation(normal operation mode), a gate output switches as rarely as possible, implying highly skewed signal probabilities for 1 or 0. On the other hand, at test mode, signals have probabilities of being 1 or 0 approaching 0.5, so it is possible to exact both stuck-at faults on the wire. Therefore, the goals of synthesis for low power and random pattern testability are achieved. The hardware overhead sof proposed design method are only one primary input for mode selection and AND/OR gate for each redundant connection.

  • PDF

저압 AC회로의 MOV 적용방안 연구 (A Study on the Utilization of Metal Oxide Varistor for Low-Voltage AC Circuits)

  • 최효열;이원빈;강영석;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1822-1824
    • /
    • 1996
  • Damage and upset of control and communication equipment due to transient overvoltages which occur due primarily to internal switching surge and external lightning surge are an important problems in electromagnetic compatibility(EMC). In this paper, we analyzed operation characteristic of metal oxide varistor widely used low voltage AC line using the electromagnetic transients program(EMTP) and compare it with experimental results and also, we modeled combination generator producing $1.2/50{\mu}s$ open circuit voltage and $8/20{\mu}s$ short circuit current as a source which is critical in calculating operation characteristic. Simulation results showed that most of Transient energy consumes at MOV located in service entrance side than load side, and it showed similar to experimental results. Therefore, entrance side MOV should be selected more energy capacity than that of load side MOV.

  • PDF

1.8GHz 대역의 저전압용 CMOS RF하향변환 믹서 설계 (A 1.8GHz Low Voltage CMOS RF Down-Conversion Mixer)

  • 김희진;이순섭;김수원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.61-64
    • /
    • 2000
  • This paper describes a RF Down-Conversion Mixer for mobile communication systems. This circuit achieves low voltage operation and low power consumption by reducing stacked devices of conventional gilbert cell mixer. In order to reduce stacked devices, we use source-follower structure. The proposed RF Down-Conversion mixer operates up to 1.85GHz at 1.5V power supply with 0.25um CMOS technology and consumes 2.2mA.

  • PDF

비안정 멀티바이브레이터를 이용한 가변속도 가능한 저전력 모터 (Variable speed control of low power motor by using the astable multivibrator)

  • 이용일
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.167-171
    • /
    • 2018
  • 현재 수없이 많은 가전제품이나 IT 부품 등에서 저전력 DC모터를 적용시켜서 회전력을 가해야 하는 곳에는, 어느 때나 어느 곳에서나 적응적인 적용이 가능한 기술이 필요함으로써, 비안정 멀티바이브레이터를 이용한 저전력 아이디어 제품을 실험적으로 개발하였다. 모터구동이 일반적으로 초기 구동시에 많은 전력을 소모하며, 정상 동작시에 저전력 동작을 이루어내는 구동원리를 이용하여, 전원 자체를 펄스 형태로 공급하여 저전력 동작을 구현하여. AC모터이든지 DC모터이든지 어느 것이든지 적용 가능한 기술실험 동작 결과를 증명하였다.

Low Cost High Power Density Photovoltaic Power Conditioning System with an Energy Storage System

  • Jang, Du-Hee;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.487-494
    • /
    • 2012
  • A new low cost high power density photovoltaic power conditioning system (PV PCS) with an energy storage system is proposed in this paper. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and the battery charger/discharger. Despite the reduced power stage, the proposed system can achieve the same performance in terms of maximum power point tracking and battery charging/discharging as the conventional system. When a utility power failure happens, the proposed system cannot perform maximum power point tracking at the UPS mode. However, the predetermined battery voltage near the maximum power point of the PV array can effectively generate a reasonable PV power even at the UPS mode. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, a theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

The Optimal Operation for Community Energy System Using a Low-Carbon Paradigm with Phase-Type Particle Swarm Optimization

  • Kim, Sung-Yul;Bae, In-Su;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.530-537
    • /
    • 2010
  • By development of renewable energy and more efficient facilities in an increasingly deregulated electricity market, the operation cost of distributed generation (DG) is becoming more competitive. International environmental regulations of the leaking carbon become effective to reinforce global efforts for a low-carbon paradigm. Through increased DG, operators of DG are able to supply electric power to customers who are connected directly to DG as well as loads that are connected to entire network. In this situation, a community energy system (CES) with DGs is a new participant in the energy market. DG's purchase price from the market is different from the DG's sales price to the market due to transmission service charges and other costs. Therefore, CES who owns DGs has to control the produced electric power per hourly period in order to maximize profit. Considering the international environment regulations, CE will be an important element to decide the marginal cost of generators as well as the classified fuel unit cost and unit's efficiency. This paper introduces the optimal operation of CES's DG connected to the distribution network considering CE. The purpose of optimization is to maximize the profit of CES. A Particle Swarm Optimization (PSO) will be used to solve this complicated problem. The optimal operation of DG represented in this paper would guide CES and system operators in determining the decision making criteria.

진공실 온도에 의한 저온진공건조기의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of the Low Temperature Vacuum Dryer by the Vacuum Chamber Temperature)

  • 최순열
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.23-28
    • /
    • 2010
  • Of the roughly four million known substances, about 60,000 are processed and sold ; many of these must be dried. Many materials are processed in the liquid state - ideal for mixing and reacting - but most products are needed or wanted as dry, or relatively dry, solids. Usually operation is just below atmospheric pressure, as with direct dryers, but some are built for vacuum operation with pressures as low as 26.66kPa abs.. In spite of the global-class aquiculture agriculture and fisheries technology of our country, the processing technologies are lags behind the other nations relatively. These problems are considered to be caused directly by the lack of drying technologies. This paper is concerned to the experimental results of drying heat transfer characteristics for the green energy type vacuum dryer for the high quality agriculture and fisheries production.

Voltage Scaling 기반의 저전력 전류메모리 회로 설계 (Design of Low Power Current Memory Circuit based on Voltage Scaling)

  • 여성대;김종운;조태일;조승일;김성권
    • 한국전자통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.159-164
    • /
    • 2016
  • 무선통신시스템은 한정된 에너지를 갖는 배터리를 사용하기 때문에 저전력 회로로 구현되어야 하며, 이를 위하여 주파수와 상관없이 일정한 전력을 나타내는 전류모드 회로가 연구되어왔다. 본 논문에서는 초저전력 동작이 가능하도록 Dynamic Voltage Scaling 전원을 유도하며, 전류모드 신호처리 중 메모리 동작에서 저장된 에너지가 누설되는 Clock-Feedthrough 문제를 최소화하는 전류메모리 회로를 제안한다. $0.35{\mu}m$ 공정의 BSIM3 모델로 Near-threshold 영역의 전원 전압을 사용한 시뮬레이션을 진행한 결과, 1MHz의 스위칭 동작에서 $2{\mu}m$의 메모리 MOS Width, $0.3{\mu}m$의 스위치 MOS Width, $13{\mu}m$의 Dummy MOS Width로 설계할 때, Clock-Feedthrough의 영향을 최소화시킬 수 있었으며 1.2V의 Near-threshold 전원전압에서 소비전력은 $3.7{\mu}W$가 계산되었다.

저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계 (Design of a Multi-Protocol Gateway System Based on Low Power Wireless Communications)

  • 홍성일;인치호
    • 한국통신학회논문지
    • /
    • 제40권10호
    • /
    • pp.2006-2013
    • /
    • 2015
  • 본 논문에서는 저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계를 제안한다. 제안 된 멀티 프로토콜 게이트웨이 시스템은 가로등 전력 제어 및 환경 모니터링을 위한 정보를 수집하여 무선 네트워크와 유선 네트워크를 통해 현장 상황을 실시간으로 모니터링 및 제어 할 수 있도록 설계하였다. 코드분할 다중접속 및 이더넷, 위성 항법장치, 저전력 무선통신 등의 유선 또는 무선통신을 선택적으로 사용한 복합처리와 함께 다중 센서를 이용하여 수집 된 데이터를 저전력 무선통신을 통해 서버로 전송하는 중개 역할을 하도록 설계하였다. 그리고 유지보수 비용 및 하드웨어 교체 용이성을 위해 CPU 및 베이스 보드로 분리하여 설계하였다. 본 논문에서 제안된 다중 프로토콜 게이트웨이 시스템의 전원, 충격, 연속동작 신뢰성 검증결과, 95% 이상의 정상동작 성공률 및 정상적인 연속동작 결과를 얻을 수 있었다. 그리고 전압 강하 및 순간 내성시험, 전도성 RF 전자기장 내성시험에서 평균 A등급의 평가결과를 얻을 수 있었다.

Deployment of Radioactive Waste Disposal Facility with the Introduction of Nuclear Power Plants (NPP) in Kenya

  • Shadrack, A.;Kim, C.L.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • 제1권1호
    • /
    • pp.37-47
    • /
    • 2013
  • This paper describes basic plans for the development of a radioactive waste disposal facility with the introduction of Nuclear Power Plants (NPPs) for Kenya. The specific objective of this study was to estimate the total projected waste volumes of low- and intermediate-level radioactive waste (LILW) expected to be generated from the Kenyan nuclear power programme. The facility is expected to accommodate LILW to be generated from operation and decommissioning of nuclear power plants for a period of 50 years. An on-site storage capacity of 700 $m^3$ at nuclear power plant sites and a final disposal repository facility of more than 7,000 $m^3$ capacity were derived by considering Korean nuclear power programme radioactive waste generation data, including Kori, Hanbit, and APR 1400 nuclear reactor data. The repository program is best suited to be introduced roughly 10 years after reactor operation. This study is important as an initial implementation of a national LILW disposal program for Kenya and other newcomer countries interested in nuclear power technology.