• Title/Summary/Keyword: Low Coherence

Search Result 153, Processing Time 0.025 seconds

2-D OCT image implementation using low coherence SLD (Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현)

  • 정태호;박양하;오상기;김용평
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

Application of Acoustic Holography to Automobile Aeroacoustic Noise of Low Coherence (낮은 상관 관계를 갖는 자동차 공력 소음에 대한 음향 홀로그래피)

  • Nam, Kyoung-Uk;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.561-564
    • /
    • 2004
  • Acoustic holography is applied to automobile aeroacoustic noise. Automobile aeroacoustic noise has low coherence due to multiple independent sources and measurement noise. This paper discusses the reliability of acoustic holography on this low coherence condition. Main subjects are the number and position of reference microphones, which is used for a step-by-step scanning method, and measurement noise. A real automobile experiment verifies the results.

  • PDF

Measurement of Glucose concentration using Polarization Sensitive Low Coherence Interferometer (Polarization Sensitive Low Coherence Interferometer를 이용한 Glucose 농도 측정)

  • 이상원;김법민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.128-129
    • /
    • 2003
  • 최근 수년간 polarimetry, Raman spectroscopy, near infrared (NIR) absorption spectroscopy, NIR scattering, optoacoustics 등의 방법을 통하여 비침습적으로 Glucose의 농도를 측정하려는 연구가 많이 시도되었다. 일반적으로 이들 방법은 sensitivity 와 signal-to-noise ratio가 매우 낮고 복잡한 알고리즘이 요구되어져 glucose 농도 측정에 한계가 있음이 드러났다. 본 연구에서는 polarization sensitive optical coherence tomography (PS-OCT)에 사용되는 polarization sensitive low coherence inter-ferometer (PS-LCI) 기법을 이용하여 비침습적으로 glucose의 농도 측정을 가능하게 하는 시스템 개발에 중점을 두었다. (중략)

  • PDF

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers for Surface-profile Metrology (펨토초 레이저를 이용한 형상 측정용 비동일 광경로 저결 맞음 간섭계)

  • Oh, Jeong-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.102-110
    • /
    • 2006
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source for enhanced precision surface-profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows unequal-path scanning interferometry, which is not feasible with white light. Second, the high spatial coherence of femtosecond pulse lasers enables large-sized optics to be tested in nonsymmetric configurations with relatively small-sized reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers (펨토초 레이저를 이용한 비동일 광경로 저결맞음 간섭계)

  • Oh J.S.;Kim S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.204-207
    • /
    • 2005
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source fer enhanced precision surface profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows performing unequal-path scanning interferometry that is not feasible with white light. Second, high spatial coherence of femtosecond pulse lasers enables to test large size optics in non-symmetric configurations with relatively small size reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

  • PDF

Effect of Interaction between Category Coherence and Base Rate on Presumption of Reasons for Preference (범주 응집성과 기저율의 상호작용이 선호의 이유 추정에 미치는 효과)

  • Doh, Eun Yeong;Lee, Guk-Hee
    • Korean Journal of Cognitive Science
    • /
    • v.31 no.3
    • /
    • pp.77-102
    • /
    • 2020
  • Some progress has been made in the study of the category coherence effect, which states that the attributes of soldiers or nuns with similarities in dress and behavior, and easily distinguished from other categories, are likely to be generalized. However, few studies have examined the fundamental psychological mechanisms that underlie this category coherence effect, and this study aims to fill this gap. For this purpose, two experiments were conducted after selecting categories with high coherence (nuns, soldiers, and flight attendants) and those with low coherence (interpreters, wedding planners, and florists). In experiment 1, we observed that the members of a category were presumed to have certain reasons to prefer [property X] (presumption of reasons for preference), with this presumption becoming stronger when [property X] was observed repeatedly in high-coherence categories than in the case of low-coherence categories. Experiment 2 showed that for the high-coherence categories, the presumption of reasons for preference was stronger when [property X], rarely seen in everyday life (base rate of 30%), was observed, while the presumption of reasons for preference was weaker when [property Y] (base rate 70%), frequently seen in everyday life, was observed. In the low-coherence categories, the presumption of reasons for preference tended to be weak for both rare and frequent attributes. That is, there were significant effects of the two-way interaction between category coherence and base rate on the presumption of reasons for preference. This study has implications for psychological essentialism and stereotyping.

Deterministic Bipolar Compressed Sensing Matrices from Binary Sequence Family

  • Lu, Cunbo;Chen, Wengu;Xu, Haibo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2497-2517
    • /
    • 2020
  • For compressed sensing (CS) applications, it is significant to construct deterministic measurement matrices with good practical features, including good sensing performance, low memory cost, low computational complexity and easy hardware implementation. In this paper, a deterministic construction method of bipolar measurement matrices is presented based on binary sequence family (BSF). This method is of interest to be applied for sparse signal restore and image block CS. Coherence is an important tool to describe and compare the performance of various sensing matrices. Lower coherence implies higher reconstruction accuracy. The coherence of proposed measurement matrices is analyzed and derived to be smaller than the corresponding Gaussian and Bernoulli random matrices. Simulation experiments show that the proposed matrices outperform the corresponding Gaussian, Bernoulli, binary and chaotic bipolar matrices in reconstruction accuracy. Meanwhile, the proposed matrices can reduce the reconstruction time compared with their Gaussian counterpart. Moreover, the proposed matrices are very efficient for sensing performance, memory, complexity and hardware realization, which is beneficial to practical CS.

A Fiberoptic Temperature Sensor Using Low-Coherence Light Source (가간섭성이 낮은 광원을 이용한 광섬유 온도 센서)

  • Kim, Gwang-Su;Lee, Hong-Sik;Im, Geun-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.691-697
    • /
    • 2000
  • A fiberoptic sensor using a low-coherence SLD as a light source has been studied. The sensor system employing an intrinsic fiber Fabry-Peort interferometer as a sensing tip and a fiber Mach-Zehnder interferometer as a processing one, overcomes the ambiguous reading caused by the highly periodic natrue of conventional high-precision interferometric sensors and provides unambiguous identification of the desired phase among several candidates on the transfer function of an interferometric signal. A tentative application to the temperature sensor shows the potential that the fiberoptic sensor has a side-dynamic range of $0-900^{\circ}C$ as well as reasonable resolution higher than $0.1^{\circ}C$ without ambiguity. Due to the inherent property of the optical fiber itself and the intrinsic fiber Fabry-Perot interferometer, the proposed fiberoptic sensor will give obvious benefits when it is applied to harsh environments to monitor some physical parameters such as temperature, strain, pressure and vibration.

  • PDF