• Title/Summary/Keyword: Loss of head

Search Result 671, Processing Time 0.03 seconds

Analysis of Reflux Cooling in the SG U-Tubes Under Loss of RHRS During Midloop Operation with Primary System Partly Open

  • Son, Young-Seok;Kim, Won-Seok;Kim, Kyung-Doo;Chung, Young-Jong;Chang, Won-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.112-127
    • /
    • 1998
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic codes, RELAP5/MOD3.2 and CATHARE2V1.3U, to the analysis of thermal-hydraulic behavior in PWRs during midloop operation following the loss of RHRS. The codes simulate an integral test, BETHSY 6.94, which was conducted in the large scale test facility of BETHSY in France. The test represents the accident where the loss of RHRS occurs during midloop operation with the pressurizer and upper head vents open and the sight level indicator broken. Besides, the hot legs are half filled with water and the upper parts of the primary cooling system are filled with nitrogen, with a letdown line open and only one SG available. The purposes of this study are to understand the physical phenomena associated with reflux cooling in the 5G U-tubes when noncondensable gas is present under low pressure and to assess the applicability of the codes to simulate the loss of RHRS event by comparing the predictions with the test results. The results of the study may contribute to actual applications for plant safety evaluation and description of the emergency operating procedure.

  • PDF

Efficacy of Intraoperative Neural Monitoring (IONM) in Thyroid Surgery: the Learning Curve (갑상선 수술에서 수술 중 신경 감시의 효용성: 학습곡선을 중심으로)

  • Kwak, Min Kyu;Lee, Song Jae;Song, Chang Myeon;Ji, Yong Bae;Tae, Kyung
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.130-136
    • /
    • 2018
  • Background and Objectives: Intraoperative neural monitoring (IONM) of recurrent laryngeal nerve (RLN) in thyroid surgery has been employed worldwide to identify and preserve the nerve as an adjunct to visual identification. The aims of this study was to evaluate the efficacy of IONM and difficulties in the learning curve. Materials and Methods: We studied 63 patients who underwent thyroidectomy with IONM during last 2 years. The standard IONM procedure was performed using NIM 3.0 or C2 Nerve Monitoring System. Patients were divided into two chronological groups based on the success rate of IONM (33 cases in the early period and 30 cases in the late period), and the outcomes were compared between the two groups. Results: Of 63 patients, 32 underwent total thyroidectomy and 31 thyroid lobectomy. Failure of IONM occurred in 9 cases: 8 cases in the early period and 1 case in the late period. Loss of signal occurred in 8 nerves of 82 nerves at risk. The positive predictive value increased from 16.7% in the early period to 50% in the late period. The mean amplitude of the late period was higher than that of the early period (p<0.001). Conclusion: IONM in thyroid surgery is effective to preserve the RLN and to predict postoperative nerve function. However, failure of IONM and high false positive rate can occur in the learning curve, and the learning curve was about 30 cases based on the results of this study.

Delayed Diagnosis of Volar Dislocation of the Distal Ulna after Treatment of the Radial Shaft Fracture (요골 간부 골절 치료 후 지연 발견된 원위 척골의 전방 탈구)

  • Jeon, Suk Ha;Lee, Sanglim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.427-432
    • /
    • 2021
  • Delayed treatment of volar dislocation of the distal radioulnar joint can result in wrist pain, limited rotation of the forearm, and degenerative arthritis that could be managed only by salvage procedures. A 24-year-old male patient presented with wrist pain and a loss of forearm rotation after surgery for a radial shaft fracture. The shaft of the radius was fixed with a plate and screws with a volar angulation of 7°. The ulnar head was dislocated volar to the distal radius, and the bone defect in the ulnar head was impacted into the volar rim of the sigmoid notch of the radius, preventing the head from being reduced in the joint. Corrective osteotomy of the malunited radial shaft and sliding osteotomy of the proximal ulnar head were performed to fill the distal bone defect. Pain and range of the forearm rotation were improved at postoperative 19 months.

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.

Early Spontaneous Recanalization of Sigmoid Sinus Thrombosis Following a Closed Head Injury in a Pediatric Patient : A Case Report and Review of Literature

  • Yun, Jung-Ho;Ko, Jung Ho;Lee, Mee Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.150-154
    • /
    • 2015
  • Cerebral venous sinus thrombosis (CVST) following a closed head injury in pediatric patients is a rare condition, and an early spontaneous recanalization of this condition is extremely rare. A 10-year-old boy was admitted with a mild, intermittent headache and nausea five days after a bicycle accident. The brain computed tomography showed an epidural hematoma at the right occipital area with pneumocephalus due to a fracture of the occipital skull bone. The brain magnetic resonance imaging and the magnetic resonance venography demonstrated a flow signal loss from the right sigmoid sinus to the right jugular vein. The diagnosis was sigmoid sinus thrombosis, so close observations were selected as a treatment for the patient because of his gradually improving symptoms; however, he complained of vomiting 14 days the after conservative treatment. The patient was readmitted for a further examination of his symptoms. The laboratory and the gastroenterological examinations were normal. Due to concern regarding the worsening of the sigmoid sinus thrombosis, the brain magnetic resonance venography was rechecked and it revealed the recanalization of the venous flow in the sigmoid sinus and in the jugular vein.

Effects of Cranio-Cervical Flexion Exercise with Visual Feedback of Forward Head Posture on Muscle Activity (시각적 피드백을 병행한 머리-목 굽힘 운동이 팔의 움직임 동안 전방머리자세의 근 활성도에 미치는 영향)

  • Kim, Minkyu;Kang, Hyojeong;Yang, Hoesong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.19-27
    • /
    • 2020
  • Purpose : We aimed to investigate the effect of cranio-cervical flexion exercises(CCFE) with visual feedback(VF) on the muscle activity of the upper trapezius in forward head posture (FHP) and whether deficits in proprioception affect the changes in muscle activity. Methods : Twenty subjects with FHP were assigned to one of 2 groups according to deficits in proprioception. The muscle activity of the upper trapezius during arm movement under three exercise conditions (resting, CCFE, and VF + CCFE). Repeated-measures analysis of variance was used to compare differences in muscle activity according to the exercise conditions between the groups and to analyze the interactions between groups and conditions. Results : Significant differences were observed in muscle activity according to the exercise condition (p<.05), with no significant differences between the groups. The muscle activity of the upper trapezius was significantly different between the resting and VF +CCFE conditions (p<.05), with no significant difference between the resting and CCFE conditions (p>.05). Conclusion : The results of this study showed that the CCFE combined with VF are an effective intervention for FHP to train deep muscles selectively. In addition, the loss of proprioceptive sensation is not related to changes in muscle activity during exercises.

Effect of Guide Nozzle Shape on the Performance Improvement of a Very Low Head Cross Flow Turbine

  • Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.19-26
    • /
    • 2014
  • The cross flow turbine attracts more and more attention for its relatively wide operating range and simple structure. In this study, a novel type of micro cross flow turbine is developed for application to a step in an irrigational channel. The head of the turbine is only H=4.3m and the turbine inlet channel is open ducted type, which has barely been studied. The efficiency of the turbine with inlet open duct channel is relatively low. Therefore, a guide nozzle on the turbine inlet is attached to improve the performance of the turbine. The guide nozzle shapes are investigated to find the best shape for the turbine. The guide nozzle plays an important role on directing flow at the runner entry, and it also decreases the negative torque loss by reducing the pressure difference in Region 1. There is 12.5% of efficiency improvement by attaching a well shaped guide nozzle on the turbine inlet.

Hydraulic Tests of Lox Pump for 75-ton class Liquid Rocket Engines (75톤급 로켓엔진용 산화제펌프의 수력성능시험)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.77-80
    • /
    • 2010
  • A series of hydraulic tests of a Lox pump are performed using water at a room temperature. According to the test results, the Lox pump satisfies its design requirement but both the head and the efficiency do not fully follow the conventional similarity rule. The deviation of the head from the rule is assumed to be due to the increased volute loss at high rotational speed. Furthermore, it is found that when the pump rotates with the flow ratio less then the design requirement the leakage flowrate seems to be increased.

  • PDF

Pathogenesis of the Post-Thyroidectomy Dysphonia (갑상선 절제술 후 발성 장애의 병인)

  • Park, Jun Hee;Do, Nam Yong
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.16-20
    • /
    • 2015
  • Post-thyroidectomy dysphonia occurs very frequently. Causes of dysphonia include recurrent laryngeal nerve (RLN) or external branch of superior laryngeal nerve (EBSL) injury, intubation, laryngotracheal fixation and other causes. Patients commonly characterized hoarseness or their voice impairment inability to short or sing and loss of loudness. Although complete recovery can be expected mostly in 3 months without obvious nerve injury, dysphonia lowers patients quality of life. The present review discuss the very kinds of causes of post-thyroidectomy dysphonia.

  • PDF

Reconstruction of the Lower Lip Following the Wide Excision of Squamous Cell Carcinoma (하구순 편평상피암의 절제후 재건 치험례)

  • Ryu Bong-Su
    • Korean Journal of Head & Neck Oncology
    • /
    • v.12 no.1
    • /
    • pp.52-57
    • /
    • 1996
  • Since the upper lip does not receive direct actinic radiation, only 5% of lip tumors develop in the upper lip, while the lower lip is the site of the remainder. Among the lower lip cancer, squamous cell carcinoma is the most common tumor, especially the vermillion border of lower lip is the most common site. The aims of reconstruction of the lip are both aesthetic effect and functional restoration and the ideal procedure must produce a aesthetically normal, not-tao-tight lip and a good sensation and muscle tone of the lip. We have a satisfactory reconstruction of a subtotal loss of lower lip after squamous cell carcinoma extirpation using Gillies fan flap and the case is presented with reviewing a many published reports.

  • PDF