• Title/Summary/Keyword: Loss of head

Search Result 665, Processing Time 0.024 seconds

Stildy on the Methodology to Prevent Neck Injury at tow Speed Rear-End Impact (저속 후면 추돌 시 목부상해 예방을 위한 연구)

  • Park Insong;Chun Yongbum;Kim Guanhee;Lim Jonghun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.29-34
    • /
    • 2005
  • 141,841 car-to-car collision had occurred in 2003, and among the accidents 51,796 were rear-end impact. According to insurance company for loss or damage, more than $60\%$ of rear-end impact victims suffer neck injury. This means at least 31,000 neck injury victims have happened in 2003. More than $97\%$ of the neck injury victims have low severity injury than A.I.S 2. Head restraint, which is designed to limit rearward head movement and equipped on seat, can considerably protect neck from rear-end impact. In this paper we evaluated head restraint geometry and drivers' sitting position according to RCAR standard and carried out low speed volunteer crash test. The crash speed is 4km/h and N.I.C value is used to determine injury probability. Through these research results we can introduce the method to prevent neck injury at rear-end impact.

Differential diagnosis of peripheral vertigo (말초성 현기증의 감별진단)

  • Bae, Chang Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Dizziness can be classified mainly into 4 types: vertigo, disequilibrium, presyncope, and lightheadedness. Among these types, vertigo is a sensation of movement or motion due to various causes. The main causes of peripheral vertigo are benign paroxysmal positional vertigo (BPPV), acute vestibular neuritis (AVN), and Meniere's disease. BPPV is one of the most common causes of peripheral vertigo. It is characterized by brief episodes of mild to intense vertigo, which are triggered by specific changes in the position of the head. BPPV is diagnosed from the characteristic symptoms and by observing the nystagmus such as in the Dix-Hallpike test. BPPV is treated with several canalith repositioning procedures. AVN is the second most common cause of peripheral vertigo. Its key symptom is the acute onset of sustained rotatory vertigo without hearing loss. It is treated with symptomatic therapy with antihistamines, anticholinergic agents, anti-dopaminergic agents, and gamma-aminobutyric acid-enhancing agents that are used for symptoms of acute vertigo. Meniere's disease is characterized by episodic vertigo, fluctuating hearing loss, and tinnitus. It is traditionally relieved with life-style modification, a low-salt diet, and prescription of diuretics. However, diagnosis and treatment of the peripheral vertigo can be difficult without knowledge of BPPV, AVN, and Meniere's disease. This article provides information on the differential diagnosis of peripheral vertigo in BPPV, AVN, and Meniere's disease.

On the Viscous Flow Around Breaking Waves Generated by a Submerged Cylinder(Part 2 : Aspects of Viscous Flow) (몰수실린더에 의하여 생성되는 쇄파주의 점성유동의 고찰(제2부: 점성유동특성))

  • B.S. Hyun;Y.H. Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • The present paper is Part 2 of three-part paper for an experimental study on breaking waves generated by a submerged cylinder. Measurements of velocity and head loss profiles at the wakes of cylinder and breaker as well as the turbulent intensities in breaking region were made to elucidate the viscous aspects of breaking waves. Their mutual correlation is also investigated. It is found that the head loss profile is an excellent indicator of the strength and extent of breaker. Very high turbulent intensities measured at and just downstream of the breaker indicate the consequence of energy transfer of wave breaking into turbulence.

  • PDF

A Study of Design factors for Increasing Energy Production in Small Hydro power with Using Long Pipe (장대관로를 이용한 소수력 발전량 향상을 위한 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1134-1139
    • /
    • 2014
  • Recently the need for renewable energy development is expanding due to the global climate change, the environmental issues and the limited fossil energy resources. Dependence of energy on overseas is high in Korea. To resolve the environmental problems and to improve the energy independence rate, the development of renewable energy is more required. The small hydro power, one of the renewable energy resources, has been developing and operating from a long time ago. If we are new developing a small hydro power with the use existing dams and reservoirs, we will design the length of inlet pipe and the diameter suitable for it. However, in case of using the existing water supply pipe which had been designed suitable for water service, the designer has to review and check that the pipe is suitable for operating a generator. In this paper, the design of small hydro power using the existing long pipe of water supply, we suggest the optimum way to reduce the water hammer in pipe which causes the unsteady flow during the load-shutdown of generator, the generator operation plan for the stable supply of water and the design factor of determining the generator capacity through the analysis between discharge and head-loss.

Comparison of Blood Loss and Meat Quality Characteristics in Korean Black Goat Subjected to Head-Only Electrical Stunning or without Stunning

  • Bakhsh, Allah;Ismail, Ishamri;Hwang, Young-Hwa;Lee, Jung-Gyu;Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.38 no.6
    • /
    • pp.1286-1293
    • /
    • 2018
  • This study assessed the effects of non-stunning (NS) and head-only electrical stunning (HOES) slaughtering condition on meat quality traits of longissimus lumborum (LL) muscle from Korean black goat (KBG). Ten KBGs (18 months) were assigned into two groups and exposed to either NS or HOES treatments. Blood loss (BL) % was measured after exsanguination, and meat quality traits including muscle pH, meat color measurements (CIE $L^*$, $a^*$, $b^*$, Chroma, and hue angle), water-holding capacity (WHC), Warner-Bratzler shear force (WBSF), and sarcomere length were measured at 24 h postmortem. Results indicated that NS and HOES had no significant difference on BL %, the rate of pH decline, meat color properties, and WHC (p>0.05). It has only a small effect on WBSF and sarcomere length values, but the difference was marginal. These results suggested that meat quality of LL muscle from goat might not be affected by slaughter methods because neither NS nor HOES did result in poor quality of meat.

Sliding Wear Behavior of UHMWPE against Novel Low Temperature Degradation-Free Zirconia/Alumina Composite

  • Lee, K.Y.;Lee, M.H.;Lee, Y.H.;Seo, W.S.;Kim, D.J.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.365-366
    • /
    • 2002
  • The sliding wear behavior of ultra high molecular weight polyethylene (UHMWPE) was examined on a novel low temperature degradation-free zirconia/alumina composite material and conventional alumina and zirconia ceramics used for femoral head in total hip joint replacement. The wear of UHMWPE pins against these ceramic disks was evaluated by performing linear reciprocal sliding and repeat pass rotational sliding tests for one million cycles in bovine serum. The weight loss of polyethylene against the novel low temperature degradation-free zirconia/alumina composite disks was much less than those against conventional ceramics for all tests. The mean weight loss of the polyethylene pins was more io the linear reciprocal sliding test than in the repeal pass rotational sliding lest for all kinds of disk materials. Neither the coherent transfer film nor the surface damage was observed on the surface of the novel zirconia/alumina composite disks during the test. The observed r,'stilts indicated that the wear of the polyethylene was closely related to contacting materials and kinematic motions. In conclusion, the novel zirconia/alumina composite leads the least wear of polyethylene among the tested ceramics and demonstrates the potential as lhe alternative materials for femoral head in total hip joint replacement.

  • PDF

Development of Pressure Drop Model for the Compartment in Reactor Containment (격납용기내 구분방사이의 압력 강하 계산모델 개발)

  • Park, Cheol;Song, In-ho;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.183-193
    • /
    • 1986
  • Full scale HDR containment experiment series pointed out that the previous containment analysis models have a number of shortcomings. One of them is on the calculational model of short term (0~2sec) pressure difference. The pressure differences between subcompartments are dependent on the flow rate, fluid density, head loss coefficient, and flow area ratio. It, however, is not known that any of them is largely attributed to the disagreement of pressure difference between the measured and the calculated values. In this study, the head loss coefficients are expressed with another form to improve the analytic model. The pressure and the pressure difference are evaluated by using COMPARE code with new correlation, and the results show better agreements with experimental values for V.42 test, but overestimate the measured values for V, 43 and underestimate for V.44.

  • PDF

Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test (진동대실험에 의한 동조액체기둥감쇠기의 동적특성)

  • Min, Kyung-Won;Park, Eun-Churn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

A Study on the Development of Hydrogen Fueled Engine : Heat Loss of Direct Injection Hydrogen Fueled Engine (수소기관 개발을 위한 기초연구(직접분사식 수소기관의 열손실))

  • Nam, Seong Woo;Lee, Jong Tai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.5 no.2
    • /
    • pp.111-119
    • /
    • 1994
  • Analysis of heat loss is needed to achieve the high performance and high efficiency in hydrogen engine. So, cooling losses at each part of the direct injection hydrogen fueled engine were measured to evaluate the behavior and distribution of heat loss. Unsteady instantaneous temperature and heat flux at cylinder head were measured by use of instantaneous temperature prove. And these results were compared with those of gasoline engine.

  • PDF

A Suggestion of Sizing System for Clean Room Wear (무진복의 치수체계에 대한 연구)

  • 이경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1044-1055
    • /
    • 2000
  • The purpose of this study is to suggest sizing chart for a clean room wear. 3 control dimensions(Stature, Bust girth, B.N.P.∼Wrist point length) were chosen as 3 axes of clean room wear size chart. A loss function was used to determined intervals of stature, Bust girth and B.N.P.∼Wrist point length of size chart, because the loss function introduces the concept of frequency to size chart for better customer's size satisfaction. From the size table whose intervals had been determined by a loss function. The 4 sizes individually were suggested for clean room wear size chart by sex. The 3 sizes individually were suggested for clean room head cover size chart by sex too. The suggested size chart would be considered more feasible than present size chart. Also they are suggested supply reference measurement chart relevant to clean room wear manufacturing for 13 most frequent sizes.

  • PDF