• 제목/요약/키워드: Loss load factor

검색결과 155건 처리시간 0.028초

부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구 (A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method)

  • 이병하;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

거래전략에 따른 송전손실배분의 경로의존성에 관한 연구 (Path-dependency of Transmission Loss Allocation using Transaction Strategy)

  • 민경일;하상현;이수원;문영현
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.924-931
    • /
    • 2008
  • This paper presents a buswise transmission loss allocation algorithm utilizing the transaction strategy. We prove that whatever calculated by any transaction strategy, the total of the allocated transmission losses of each bus, including no-load loss allocation, almost equals the total loss of AC power flow algorithm and the loss is perfectly slackbus-independent. In this paper, the allocated transmission losses of each bus is calculated by the method of integrating loss sensitivities using by the load level parameter ${\lambda}$. The performance of the proposed algorithm is evaluated by the case studies carried out on the WSCC 9-bus and IEEE 14-bus systems.

발전비용의 부하역률 감도와 종합비용을 활용한 효과적인 역률개선 방안 연구 (A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost and Integrated Costs)

  • 이병하;오민혁;김정훈;심건보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.284-286
    • /
    • 2003
  • The low load power factor causes various problems such as the Increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost and integrated costs are used for determining the locations and capacities of reactive power compensation devices effectively and for enhancing the load power factor appropriately. It is shown through the application to a small-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

두 종류의 부하곡선에 관한 공급지장시간기대치(LOLE)의 상호 변환관계성 (Conversion Function and Relationship of Loss of Load Expectation Indices on Two Kinds of Load Duration Curve)

  • 이연찬;오웅진;최재석;차준민;최홍석;전동훈
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.475-485
    • /
    • 2017
  • This paper develops a conversion function and method transforming from daily peak load curve used $LOLE_D$ [days/year] to hourly load curve used $LOLE_H$[hours/year]and describes relationship between $LOLE_D$ [days/year] and $LOLE_H$ [hours/year]. The indices can not only be transformed just arithmetically but also have different characteristics physically because of using their different load curves. The conversion function is formulated as variables of capacity and forced outage rate of generator, hourly load daily load factor and daily peak load yearly load factor, etc. Therefore, the conversion function (${\gamma}={\varphi}$(.)) can not be simple. In this study, therefore, the function is formulated as linear times of separated two functions. One is an exponential formed conversion function of daily load factor. Another is formulated with an exponential typed conversion function of daily peak load yearly load factor. Futhermore, this paper presents algorithm and flow chart for transforming from $LOLE_D$[days/year] to $LOLE_H$[hours/year]. The proposed conversion function is applied to sample system and actual KPS(Korea Power System) in 2015. The exponent coefficients of the conversion functions are assessed using proposed method. Finally, assessment errors using conversion function for case studies of sample system and actual system are evaluated to certify the firstly proposed method.

부하역률 감도기법 적용에 의한 효율적인 부하역률 개선에 관한 연구 (A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost)

  • 이병하;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.18-24
    • /
    • 2005
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is derived and it is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the voltage variation penalty cost is introduced and the integrated costs including the voltage variation penalty cost are used for determining the value of the load power factor from the point of view of the economic investment and voltage regulation. It is shown through the application to a large-scale power system that the load power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

부하수준 별 한계손실계수 변동특성 분석 (Analysis of MLF Characteristics on 12 Load Levels)

  • 문영환;김호용;남궁재용;심우정
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.284-289
    • /
    • 2002
  • The transmission networks do not consist of perfect conductors and a percentage of the power generated is therefore lost before it reaches the loads. Since this network loss contributes to the cost of suppling power to consumers, it must be considered that the most efficient dispatch and location of generators and loads are to be achieved. In this paper, marginal loss factors are calculated for 12 load levels that represent the impact of marginal network losses on nodal prices at the transmission network connection points at which generators are located. Based on comparison analysis of marginal loss factors on 12 load levels, we found the MLF characteristics in KOREA.

바닥충격음 완충재의 재하시간에 따른 동적 특성 연구 (A Study on the Dynamic Properties by Loading Time of Floor Impact Noise Insulation Materials)

  • 김흥식;진필화;주시웅;정성원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.942-945
    • /
    • 2005
  • The purpose of this study is to suggest a fundamental data for change of dynamic properties according to the loading time of resilient materials. 18 kinds of resilient materials included 4 representative types were measured at the load time of 24hours and 2hours by the method of Korea standard (KS F 2868) measuring the dynamic stiffness and the loss factor of materials under floating floors. As a result, the dynamic stiffness was increased rapidly in case of expandable polystyrene and rubber materials according to the load time, especially before 2 hours. The loss factor was represented that rubber materials with high elasticity are high, and expandable polystyrene, polyester, poly ethylene materials with low elasticity are low.

  • PDF

지형공간정보체계와 토양유실모형을 이용한 토양유실량과 유사량에 대한 비교 (Comparison Sediment load with Soil Loss Using Revised Universal Soil Loss Equation and Geo-Spatial Information System)

  • 박재훈;양인태;김동문;천기선
    • 한국측량학회지
    • /
    • 제18권3호
    • /
    • pp.225-231
    • /
    • 2000
  • 강우에 의한 토양유실은 환경에 침각한 영향을 미치고 있음에도 불구하고, 인식의 부족으로 실제 유역에서 발생되고 있는 유실량을 측정한 자료가 없는 실정이다. 본 연구에서는 수정토양유실모형을 지리정보체계와 통합하여 홍천강유역에 적용해 봄으로써 발생 가능한 유실량을 정량적으로 예측하였으며, 홍천강 유역에서 측정한 유사량 자료와 비교 분석을 통하여 그 상관성을 알아보았다. 수정토양유실모형에 필요한 각각의 인자들은 격자분석을 통하여 수행하였으며. 지형인자는 추출과정을 프로그램화하여 효율성을 높였다.

  • PDF

변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정 (Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency)

  • 김종민;김영석;길형준;송길목
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

단상전원에 접속된 3상 유도전동기의 손실분석 (Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source)

  • 김도진;좌종근
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.