An anti-noise real-time cross-correlation method for bolted joint monitoring using piezoceramic transducers

  • Ruan, Jiabiao;Zhang, Zhimin;Wang, Tao;Li, Yourong;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제16권2호
    • /
    • pp.281-294
    • /
    • 2015
  • Bolted joint connection is the most commonly used connection element in structures and devices. The loosening due to external dynamic loads cannot be observed and measured easily and may cause catastrophic loss especially in an extreme requirement and/or environment. In this paper, an innovative Real-time Cross-Correlation Method (RCCM) for monitoring of the bolted joint loosening was proposed. We apply time reversal process on stress wave propagation to obtain correlation signal. The correlation signal's peak amplitude represents the cross-correlation between the loosening state and the baseline working state; therefore, it can detect the state of loosening. Since the bolt states are uncorrelated with noise, the peak amplitude will not be affected by noise and disturbance while it increases SNR level and increases the measured signals' reliability. The correlation process is carried out online through physical wave propagation without any other post offline complicated analyses and calculations. We implemented the proposed RCCM on a single bolt/nut joint experimental device to quantitatively detect the loosening states successfully. After that we implemented the proposed method on a real large structure (reaction wall) with multiple bolted joint connections. Loosening indexes were built for both experiments to indicate the loosening states. Finally, we demonstrated the proposed method's great anti-noise and/or disturbance ability. In the instrumentation, we simply mounted Lead Zirconium Titanate (PZT) patches on the device/structure surface without any modifications of the bolted connection. The low-cost PZTs used as actuators and sensors for active sensing are easily extended to a sensing network for large scale bolted joint network monitoring.

나사 풀림 방지를 위한 걸림턱 구조의 와셔 개발 및 성능 비교 (Development and Benchmark Test of Hole-Boss Locking Washers for the Prevention of Vibrational Loosening)

  • 오영탁;김기대
    • 한국기계가공학회지
    • /
    • 제19권8호
    • /
    • pp.28-34
    • /
    • 2020
  • In this study, hole-boss locking washers were developed to prevent vibrational loosening, and a benchmark test was conducted to compare these washers with existing wedge locking washers, which are imported and high-priced. The developed washers consist of an upper washer with bosses and a lower washer with holes, and the bosses are caught in the holes so that the bolt is not loosened. Additionally, the top side of the upper washer and the underside of the lower washer have small wedges perpendicular to the direction of the bolt loosening, suppressing slips. A test by the Korea Test Laboratory indicated that the ratio of the loosening torque to the joining torque is greater than 70%, confirming that the developed washers have a sufficiently high anti-loosening performance. A Junker test apparatus was manufactured for the testing of vibrational loosening and a test comparison between the proposed washers and the existing wedge locking washers shows that the proposed washers have a slower reduction in the clamping force and a higher loosening-resistance in a vibrational circumstance compared with the wedge locking washers. These results indicate that the developed washers demonstrate a high performance and boast price competitiveness.

지대주와 고정체의 체결방법에 따른 임플란트의 풀림거동에 관한 연구 (Effect of connection type on the screw loosening of implant system)

  • 최재민;전흥재;한종현;이수홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.486-491
    • /
    • 2004
  • A comparative study on the implant screw loosening under the initial clamping force and cyclic loads was conducted. The experiments were performed to evaluate the screw loosening behavior of the internal and external implant systems. It was found that the screw loosening torques of implant systems were significantly affected by the way how the abutment and fixture were connected due to the difference in the load transfer mechanism between abutment and fixture.

  • PDF

Influence of cable loosening on nonlinear parametric vibrations of inclined cables

  • Wu, Qingxiong;Takahashi, Kazuo;Chen, Baochun
    • Structural Engineering and Mechanics
    • /
    • 제25권2호
    • /
    • pp.219-237
    • /
    • 2007
  • The effect of cable loosening on the nonlinear parametric vibrations of inclined cables is discussed in this paper. In order to overcome the small-sag limitation in calculating loosening for inclined cables, it is necessary to first derive equations of motion for an inclined cable. Using these equations and the finite difference method, the effect of cable loosening on the nonlinear parametric response of inclined cables under periodic support excitation is evaluated. A new technique that takes into account flexural rigidity and damping is proposed as a solution to solve the problem of divergence. The regions of inclined cables that undergo compression are also indicated.

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.

체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구 (Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force)

  • 이용우;장용훈
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인 (The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations)

  • 홍수정;배정윤;김현희
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.212-217
    • /
    • 2018
  • 목적: 본 연구의 목적은 구치부 식립 임플란트에서 지대주 나사 풀림의 발생 빈도 및 지대주 나사 풀림에 영향을 주는 다양한 요인들을 후향적 연구를 통하여 평가하는 것이다. 대상 및 방법: 2013년 1월부터 2016년 1월까지 208명의 환자에서 구치부에 식립한 391개의 임플란트를 대상으로 하였다. 모든 수복물은 고정성으로 단일 혹은 연결 크라운, 브릿지로 제작되었으며, 임시 시멘트로 합착하였다. 전체 수복물 중 지대주 나사 풀림의 발생 빈도를 조사하였고, 성별, 보철물의 위치, 대합치, 보철물의 유형, 지대주 연결 유형, 매식체의 지름이 지대주 나사 풀림에 미치는 영향을 평가하였다. 결과: 2 - 5년의 관찰 결과, 총 29개(7.4%)의 임플란트에서 지대주 나사 풀림이 발생하였다. 최종 수복 후 지대주 나사 풀림이 발생하기까지 소요된 기간은 3개월부터 48개월(평균19.5개월)까지 다양하게 나타났으며, 이 중 3개의 임플란트에서 매식체의 파절이 발생되었다. 고려 요인들 중, 임플란트의 식립 위치에 따라 대구치(9.4%)와 소구치(2.6%)에서 통계적으로 유의한 차이를 보였으며(P < .019), 대합치에 따라 자연치(9.9%), 임플란트(1.0%), 가철성 보철물(0%)에서 유의한 차이를 보였다(P < .018). 다른 고려 요인에 따른 지대주 나사 풀림 발생 빈도는 통계적 유의성이 없었다. 결론: 구치부 임플란트 수복물에서 지대주 나사 풀림의 발생 빈도는 7.4%로 나타났다. 소구치보다 대구치에서 유의하게 높은 발생 빈도를 보였으며, 대합치에 따라서는 임플란트, 가철성 보철물과 비교 시 자연치에서 유의하게 높은 발생 빈도를 보였다.

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

치과 임플란트 스크루 풀림토크 개선용 DLC 박막 코팅에 관한 연구 (A Study on the DLC Film Coating for Improving Loosening Torque of Dental Implant Screw)

  • 정운조;조재철
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1375-1381
    • /
    • 2018
  • In this paper, we studied coatings of the DLC thin film for improving loosening torque of dental implant screw. We used a filtered arc ion plating process which can realize the most dense DLC layer by coating the DLC thin film on the surface of the dental abutment screw. It showed both hardness comparable to diamond and low friction coefficient similar to graphite, and to improve the loosening phenomenon by increasing the screw tightening force Cr/CrN, Ti/TiN or Ti/TiN/Cr/CrN buffer layers were deposited for 5 to 10 minutes to improve the adhesion of the DLC thin film to the surface of the Ti (Gr.5), and then the DLC thin film was coated for about 15 minutes. As a result, the Cr/CrN buffer layer exhibited the highest hardness of 29.7 GPa, the adhesion of 18.62N on average, and a very low coefficient of friction of less than 0.2 as a whole. And we measured loosening torque after one million times with masticatory movement simulator. As a result, the values of the coated screw loosening torque were clearly higher than those of the uncoated screw. From this, it was found that the DLC coating was effective methods improving the loosening torque. In addition, it was confirmed that the cytotoxicity test and cell adhesion test showed high biocompatibility.

조임 회전력에 따른 치과 임플랜트 지대나사의 응력에 관한 연구 (STRESS OF DENTAL IMPLANT ABUTMENT SCREW BY THE TIGHTENING TORQUE)

  • 이원주;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.721-737
    • /
    • 1998
  • Abutment screw loosening of implant restorations is a common problem in the treatment of dental implant. The purpose of this study was to calculate stress and preload from the elongation measurements and to determine maximum tightening torque without plastic deformation of the screw. The length of each gold alloy UCLA screw was measured after tightening to the manufacturer's recommended torque of 32 N-cm. Similarity, titanium UCLA screws were measured after tightening to the manufacturer's recommended torque of 20 N-cm. Loosening torque was also measured after tightening to 32 N-cm torque for gold alloy abutment screws and 20 N-cm for titanium abutment screws. The results were as follows ; 1. There was a regressive relationship between screw elongation and tightening torque (gold alloy : $r^2=0.987$, titanium : $r^2=0.978$), and the mean preload calculated from elongation measurements was $501.11{\pm}26.85\;N$ (gold alloy) and $399.43{\pm}7.61\;N$ (titanium). 2. Stress calculated for the gold alloy and titanium screws at maximum recommended tightening torque was less than 60% of their respective yield strengths and with-in the elastic range. Maximum tightening torque without plastic deformation was 61 N-cm (gold alloy) and 39 N-cm (titanium). 3. For titanium screws, there was a significant difference between loosening after trial 1 and loosening after trials 2 to 5 (p<0.05). No statistically significant difference was seen in mean loosening torques between the first and subsequent trials for gold alloy screws.