• Title/Summary/Keyword: Loop size

Search Result 465, Processing Time 0.039 seconds

Design of the Crab label tag with a loop matching feed and a modified dipole structure at 900 MHz

  • Choi, Eui-Sun;Lee, Hak-Yong;Lee, Jin-Seong;Lee, Kyoung-Hwan;Lee, Sa-Won;Lee, Young-Hie
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.551-555
    • /
    • 2011
  • The Crab label tag with a loop matching feed and a modified dipole antenna structure was proposed. The antenna impedance is conjugated easily to a radio frequency identification IC chip impedance by a loop matching feed. The reading range of the crab structure tag is 0.9-1.0 m from the upper side of the formula milk can lid. The fabricated label tag size is $44.0{\times}44.0mm^2$. The operating frequency at -3 dB return loss is 861.0-929.0 MHz, and the maximum reading range at the anechoic chamber is 1.5 m.

Implementation of Power Line Transmission System Using DDLL (디지털 지연동기루프(DDLL)를 이용한 전력선 전송시스템의 구현)

  • 오호근;정주수;변건식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-64
    • /
    • 1997
  • Spread Spectrum Communication is a core technique in CDMA system, but the problem for SS Communication schemes is synchronous method. There are DLL, Tau-dither, SO etc, in the synchronous method. But since there are analog operations, the settling is difficult and size is large. In this paper we realized Digital Delay Lock Loop (DDLL) and estimated it's performance through the Power line experiment.

  • PDF

Experimental Study on Instability of Two-Phase Loop Thermosyphon (루프형 2상 유동 열사이폰의 유동 불안정에 관한 실험적 연구)

  • 이석호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.408-414
    • /
    • 2002
  • The instability of two-phase loop thermosyphons (TLTs) was investigated experimentally. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7mm (no insert) to 0.71mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT.

Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System (모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석)

  • Kim, Byeong-Gi;Seo, Jeong-Se;Hwang, Geon;Mun, Seok-Hwan;Bae, Chan-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

An Effective Control Scheme for Battery Charger System in Electric Vehicles

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.232-233
    • /
    • 2012
  • This paper presents an effective control scheme for an electric vehicle battery charger where a symmetrical bridgeless power factor-corrected converter and a buck converter are cascaded. Both converters have been popular in industries because of their high efficiency, low cost, and compact size, hence combining these converters makes the overall battery charging system strongly efficient. Moreover, this charger topology can operate at universal input voltage and attain a desired battery current and voltage without ripple. In order to achieve a unity input power factor and zero input current harmonic distortion, the proposed control scheme adopts duty ratio feed-forward control technique in both current and voltage control loop. Additionally, in the current loop, its reference is created by a phase-locked loop (PLL) block, leading to a pure sinusoidal input current although the input voltage waveform is being distorted. The feasibility and practical value of the proposed approach are verified by simulation and experiment with an 110V/60Hz ac line input and 1.5kW-72V dc output of the battery charging system.

  • PDF

Abundance and Structure of Microbial Loop Components (Bacteria and Protists) in Lakes of Different Trophic Status

  • Chrost, Ryszard J.;Tomasz, Adamczewski;Kalinowska, Krystyna;Skowronska, Agnieszka
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.858-868
    • /
    • 2009
  • The abundance, biomass, size distribution, and taxonomic composition of bacterial and protistan (heterotrophic and autotrophic nanoflagellates and ciliates) communities were investigated in six lakes of Masurian Lake District (north-eastern Poland) differing in trophic state. Samples were taken from the trophogenic water layer during summer stratification periods. Image analysis techniques with fluorescent in situ hybridization (FISH) as well as [$^3H$]-methyl-thymidine incorporation methods were applied to analyze differences in the composition and activity of bacterial communities. The greatest differences in trophic parameters were found between the humic lake and remaining non-humic ones. The same bacterial and heterotrophic nanoflagellate (HNF) cell size classes dominated in all the studied lakes. However, distinct increases in the contributions of large bacterial (>$1.0{\mu}m$) and HNF (>$10{\mu}m$) cells were observed in eutrophic lakes. The bacterial community was dominated by the ${\beta}$-Proteohacteria group, which accounted for 27% of total DAPI counts. Ciliate communities were largely composed of Oligotrichida. Positive correlations between bacteria and protists, as well as between nanoflagellates (both heterotrophic and autotrophic) and ciliates, suggest that concentrations of food sources may be important in determining the abundance of protists in the studied lakes.

A Study on the Miniature Loop Heat Pipe with Non-inverted Meniscus type Capillary Structure (Non-inverted Meniscus식 모세관 구조물을 이용한 소형 루프히트파이프에 관한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Doctarau, Viachaslau-V.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2142-2147
    • /
    • 2007
  • Experimental study was conducted to evaluate the performance of a miniature loop heat pipe (MLHP) with non-inverted meniscus type capillary structure. All parts of MLHP in this study were made of copper including the capillary structure and the distilled water was used as a working fluid of MLHP. The outer diameter of evaporator was 9 mm and its length was 119 mm. The effective pore size of the capillary structure was 30 micron and its porosity was 60%. The vapor transport line, the liquid transport line and the condenser were consisted of single 4.0 mm copper tube. The distance between the evaporator and the condenser region was 200 mm and the length of the loop was 969 mm. This MLHP was operated successfully at any orientation but the gravity highly influenced the thermal performance of the MLHP. The maximum thermal load was 130 watts at the bottom heat mode and the 20 watts at the top heat mode.

  • PDF

Design and Implementation of Internal Multiband Loop Embedded Monopole Antenna for Mobile Handset

  • Jung, Pil Hyun;Yang, Cheol Yong;Lee, Seong Ha;Yang, Woon Geun
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.484-491
    • /
    • 2013
  • In this paper, we proposed an internal multiband loop embedded monopole antenna for mobile handset that could be used for smart phones. The proposed antenna has a volume of 40 mm(W) ${\times}$ 15 mm(L) ${\times}$ 5 mm(H), ground plane size is 40 mm(W) ${\times}$ 80 mm(L), and covers the GSM900 (Global System for Mobile communications : 880-960 MHz), K-PCS (Korea-Personal Communications Service : 1750-1870 MHz), US-PCS (US Personal Communications Service : 1850-1990 MHz), WCDMA (Wideband Code Division Multiple Access : 1920-2170 MHz), Wibro (2300-2390 MHz), Bluetooth (2400-2483 MHz) and WLAN (Wireless Local Area Network : 2400-2483.5 MHz) bands for VSWR (voltage standing wave ration) less than 3. The proposed loop adding design at middle section of longest branch showed wide impedance bandwidth for the lowest resonance frequency band. The proposed antenna have a lowest resonance frequency band from 738 MHz to 1075 MHz for S11 value of -6dB. A HFSS (High Frequency Structure Simulator) of the Ansys Corporation based on a finite element method is employed to analyze the proposed antenna in the design process and to compare the simulation and experimental results.

An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity (지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구)

  • Kong, Hyoung-Jin;Lim, Hyo-Jae;Choi, Jae-Ho;Sohn, Byong-Hu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

Therapeutic Effect of a Double Locking-loop Suture Pattern on the Elbow Luxation with Rupture of Collateral Ligament in a Dog (곁인대가 파열되고 주관절이 탈구된 개에서 이중 Locking-loop 봉합법의 치료효과)

  • Lee Jae-yeong;Kim Joong-hyun;Kim So-seob;Lee Seung-keun;Choi Seok-hwa
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.406-408
    • /
    • 2004
  • A nine-month-old male Jindo with non weight-bearing on the right forelimb in flexed position, pain and edema of the elbow, and resist elbow extension was brought to the Veterinary Teaching Hospital, Chungbuk National University. Elbow radiographs showed loss of humeroradial joint space and lateral displacement of the radius and ulna. Closed reduction was reported the best therapy in most cases of luxation of the elbow but conservative reduction was impossible. Open reduction of the luxated elbow was performed and ruptured collateral ligaments were identified. Displaced elbow was required bloody surgical operation and gentle reduction to restore elbow joint. Internal reduction of choice for elbow luxation with rupture of collateral ligament in the dog was a double locking-loop suture pattern. To ensure secure grasping of parallel bundles of ligament fibers to transverse bites of each suture were placed superficial to the longitudinal bites. All ligaments were repaired with 3-metric (size 2 USP) monofilament polypropylene suture. No complications have been noted during a five-month follow up.