• Title/Summary/Keyword: Loop Power Distribution System

Search Result 81, Processing Time 0.027 seconds

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.

Development of RTDS-MATLAB Integrated Simulation Environment for Development and Verification of Voltage Measurement based CVR Control Algorithm (전압계측기반 CVR제어 알고리즘 개발 및 검증을 위한 RTDS-MATLAB 연동 시뮬레이션 환경 개발)

  • Go, Seok-Il;Ahn, Seon-Ju;Choi, Joon-Ho;Nam-Koong, Won;Shin, Chang-Hoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.549-556
    • /
    • 2016
  • CVR is a technique for reducing power consumption by reducing the voltage of the system and many demonstrations and studies have been conducted in the past. Recently, SCADA-based or AMI-based VVC have been developed and the CVR is used as an important operation mode. Using a variety of instruments, CVR determines the optimal VVC control references by closed loop control. In this paper, we implemented RTDS-MATLAB integrated simulation environment for development and verification of CVR control algorithm based on voltage measurement. The voltage control device of distribution system was modeled using RTDS and MATLAB has constructed a controller that can measure and control the voltage of the simulation system of RTDS. After the capacitor, which is a reactive power control device, flattens the voltage of the system, the control algorithm reduces the voltage of the system by tap control of the OLTC based on the flatten voltage. The proposed system was verified by simulations.

A basic study on protective relay testing using RTDS in power system applying SFCL (초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Kim, Jae-Ho;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

A study on the EMI in special power distribution zone on ship (선내 특별 전원 분배구역의 EMI에 관한 연구)

  • Park, Jong-Sung;Choi, Gi-Do;Kim, Jong-Woo;Cho, Hyung-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.730-736
    • /
    • 2014
  • Test standards for electrical and electronic equipment required for ship operations is applying the IEC-60533 standard. However, although a test procedure and a specified regulation are clearly defined in the deck and bridge zone and general power distribution zone, they are not regulated in the special power distribution zone with ship propulsion system. For these reasons, the costs for additional research and development have been invested. In this paper, we was measured power noise in a special power distribution zone in ship and we were compared and analyzed values measured. The actual experiments are performed on the ship of Korea Maritime and Ocean University. As a result, the acquired data on Hanbada shows that loop antenna with low frequency band(160kHz) and ultra log antenna with high frequency band(1.97GHz)occur about 6-8dB differences and about 8.7 difference respectively. Also, the acquired data on Hannara shows that each loop antenna of 1MHz, 11MHz, and 25MHz occurs about 7dB difference about 4-5dB differences respectively. so standard of Special distribution zone must be specified by comparative analysis of data obtained by the experiment more.

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

Preliminary numerical study on hydrogen distribution characteristics in the process that flow regime transits from jet to buoyancy plume in time and space

  • Wang, Di;Tong, Lili;Liu, Luguo;Cao, Xuewu;Zou, Zhiqiang;Wu, Lingjun;Jiang, Xiaowei
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1514-1524
    • /
    • 2019
  • Hydrogen-steam gas mixture may be injected into containment with flow regime varying both spatially and transiently due to wall effect and pressure difference between primary loop and containment in severe accidents induced by loss of coolant accident. Preliminary CFD analysis is conducted to gain information about the helium flow regime transition process from jet to buoyancy plume for forthcoming experimental study. Physical models of impinging jet and wall condensation are validated using separated effect experimental data, firstly. Then helium transportation is analyzed with the effect of jet momentum, buoyancy and wall cooling discussed. Result shows that helium distribution is totally dominated by impinging jet in the beginning, high concentration appears near gas source and wall where jet momentum is strong. With the jet weakening, stable light gas layer without recirculating eddy is established by buoyancy. Transient reversed helium distribution appears due to natural convection resulted from wall cooling, which delays the stratification. It is necessary to concern about hydrogen accumulation in lower space under the containment external cooling strategy. From the perspective of experiment design, measurement point should be set at the height of connecting pipe and near the wall for stratification stability criterion and impinging jet modelling validation.

Optimal Routing for Distribution System Planning using heuristic strategy (휴리스틱 탐색전략을 이용한 배전계통 계획의 최적경로탐색)

  • Choi, Nam-Jin;Kim, Byung-Seop;Shin, Joong-Rin;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.142-146
    • /
    • 2000
  • This paper Presents a heuristic algorithm based on branch exchange method to solve ORP (Optimal Routing Problem) for distribution system planning. The ORP is a complex task which is generally formulated as a combinatorial optimization problem with various constraints. The cost function of ORP is consisted of the investment cost and the system operation cost that is generally expressed with system power loss. This paper also adopt an specialy designed selection method of maximum loss reduction loop and branch to reduce optimization time. The effectiveness of the proposed algorithm was shown with 32, 69 bus example system.

  • PDF

Development of Three Phase Optimal Power Flow for Distributed Generation Systems (분산전원계통을 위한 3상 최적조류계산 프로그램 개발)

  • Song, Hwa-Chang;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.882-889
    • /
    • 2010
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow (3POPF). 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique for 3POPF, this paper adopts a simulation-based method of particle swarm optimization (PSO). In the PSO based 3POPF, a utility function needs to be defined for evaluation of the degree in operational improvement of each particle's current position. To evaluate the utility function, in this paper, NR-based 3 phase power flow algorithm was developed which can deal with looped distributed generation systems. In this paper, illustrative examples with a 5-bus and a modified IEEE 37-bus test systems are given.

Single Phase Power Circuit Analysis of a Series Voltage Compensator (직렬형 전압보상기의 단상 전력회로 해석)

  • Lim, Yong-Bin;Lim, Su-Saeng;Lee, Eun-Woong;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.302-304
    • /
    • 1999
  • Voltage sag and swell are the most severe factors affecting power quality in distribution systems. This paper discusses an approach to ensure a high quality power supply to critical loads appling voltage-sag compensator. The proposed system consists of a PWM voltage source inverter, connected in series with the line through a single-phase transformer. The operation Principle and Power circuit configuration of the proposed voltage sag compensator are introduced. And then the transfer function of compensator is derived from simplified single phase power circuit, and simulated so that the benefits of this proposed compensator is confirmed through the open loop response.

  • PDF

An Analysis of the Reliability Benefit for Loop Operation in Power Distribution System (배전계통 루프운전시 신뢰도 이득 분석)

  • Lee, Hee-Tae;Kim, Jae-Chul;Moon, Jong-Fil
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.16_17
    • /
    • 2009
  • 지능형 배전망을 추구하기 위해 본 논문에서는 배전계통의 루프 구성과 방사상의 보호협조 방법을 수정한 새로운 루프구성에 대한 보호협조를 제안하였다. 그리고 배전 자동화가 되어 있다는 전제 하에서 제안된 보호협조 방법을 토대로 방사상 계통과 방사상 보호협조를 그대로 적용한 루프 배전계통, 마지막으로 제안된 보호협조 방법을 적용된 루프 계통에 대한 신뢰도 이득을 분석하였다.

  • PDF