• 제목/요약/키워드: Longitudinal Resolution

검색결과 54건 처리시간 0.024초

Resolution Enhancement of Scanning Tomographic Acoustic Microscope System

  • Ko, Daesik
    • The Journal of the Acoustical Society of Korea
    • /
    • 제15권1E호
    • /
    • pp.70-76
    • /
    • 1996
  • We proposed to use shear waves instead of longitudinal waves in a STAM (scanning tomographic acoustic microscope system) in which the specimens are solid. For any specimen with a shear modulus, mode conversion will take place at the water-solid interface. Some of the energy of the insonifying longitudinal waves in the water will convert to shear wave energy within the specimen. The shear wave energy is detectable and can be used for tomographic reconstruction. The resolution limitation of STAM depends on the available angular view and the acoustic wavelength. While wave transmission in most solid specimens is limited to about 20°for longitudinal waves, we show that it is about twice that high for shear waves. Since the wavelength of the shear wave is shorter than that of the longitudinal wave, we are able to achieve the high resolution. In order to compare the operation of a shear-wave STAM with that of the conventional longitudinal-wave STAM we have simulated tomographic reconstruction for each. Our simulation results with aluminum specimen and back-and-forth propagation algorithm showed resolution of a shear-wave STAM is better than that of a longitudinal-wave STAM.

  • PDF

Conoscopic holography의 이론적인 해상도에 대한 연구 (A study on the Theoretical Resolution of Conoscopic Holography)

  • 김수길;고명숙
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.1-5
    • /
    • 2014
  • Conoscopic holography, which consists of two circular polarizers and an uniaxial crystal, is incoherent holographic technology for three-dimensional display and non-contact diagnosis. In this paper, we derive the longitudinal and lateral intensities from point-source hologram made by conoscopic holography. Also, the longitudinal and lateral resolutions of conoscopic holography will be obtained from the longitudinal and lateral intensities, respectively, according to Rayleigh criterion.

횡파를 이용한 SLAM의 분해능 개선 (Resolution Enhancement of Scanning Laser Acoustic Microscope Using Transverse Wave)

  • 고대식;박준석;김영환
    • 비파괴검사학회지
    • /
    • 제16권4호
    • /
    • pp.234-240
    • /
    • 1997
  • 기존의 Scanning Laser Acoustic Microscope (SLAM)에 횡파를 사용함으로써 분해능을 개선시키는 방법을 연구하였다. 액체-고체 경계에서는 모드 변환이 발생하여 액체에서 입사되는 종파 에너지의 일부분은 고체 시험편 내에서 횡파 에너지로 변환된다. SLAM의 분해능은 수신측의 레이저 빔 폭과 입사되는 초음파의 파장에 의하여 결정되고, 고체에서 횡파의 파장은 같은 주파수의 종파의 파장보다 짧기 때문에 횡파를 사용한다면 높은 분해능을 얻을 수 있다. 종파와 횡파를 사용하였을 때에 얻어지는 SLAM 영상을 시뮬레이션을 통하여 비교하여 횡파를 이용하면 분해능이 향상됨을 입증하였다. SLAM을 횡파 모드에서 동작시키기 위하여 입사각을 조절할 수 있는 ??지를 제작하였고, 알루미늄 시험편에 대하여 실험한 결과로부터 종파 모드 SLAM에 의한 영상보다는 횡파 모드 SLAM의 영상의 콘트라스트가 양호함을 확인하였다.

  • PDF

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

수리동역학적 모의를 위한 적정 격자해상도 산정방법 (Evaluation of Optimal Grid Resolution for Hydrodynamic Proper Simulation)

  • 안정민;박인혁;류시완;허영택
    • 대한공간정보학회지
    • /
    • 제20권1호
    • /
    • pp.109-116
    • /
    • 2012
  • 본 연구에서는 CCHE2D와 EFDC모형을 이용한 모의를 통하여 격자의 횡단해상도에 따른 물리적 지형의 재현성과 모의결과에 대한 영향을 검토하고자 하였다. 낙동강 금호강 유입구간을 대상으로 2006년 강우사상에 대한 부정류모의를 통하여 면적고도곡선과 대상구간내 수위관측소 지점에서의 실측치와 모의치간의 비교를 통하여 구성격자망의 적정성 및 모의결과에 대한 영향을 각각 검토하였다. 일반적으로 격자 해상도의 증가는 계산시간의 증가를 야기하므로 수행 내용과 목적, 계산의 효율성 측면에서 적절한 격자해상도의 선택이 필요하다. 정밀한 모의를 위해서는 고해상도 격자를 이용한 모의를 수행해야 하나, 빠른 의사결정이 요구되는 홍수기와 같이 모형수행의 효율성을 고려해야 하는 경우에 적용 가능한 물리적 지형의 재현성과 결과에 대한 신뢰성을 보장할 수 있는 적정 격자 해상도가 존재함을 확인할 수 있었다.

고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징 (Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo)

  • 조한샘;장선주;오왕열
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.67-71
    • /
    • 2014
  • 혈관 내 OCT (optical coherence tomography) 는 혈관 벽 내부의 3차원적 미세구조를 영상화할 수 있어서 임상에서 각광을 받고 있다. 하지만 아직도 충분하지 못한 이미징 속도, 특히 내시경 프로브의 이미징 광 스캐닝 속도의 부족으로 혈관 길이 방향의 이미징 간격이 실제 시스템의 광학적 해상도보다 5배 이상 커서 혈관 종방향으로의 고해상도 이미징이 얻어지지 못하고 있는 상황이다. 본 논문에서는 초당 350장의 혈관 벽 단층 영상을 제공하는 고속 혈관 내 OCT 시스템을 기술한다. 본 시스템과 내시경 장치를 이용하여 47 mm 길이의 살아있는 토끼 대동맥을 3.7초만에 34 micron의 혈관 종방향 간격으로 얻는데 성공하였다. 34 micron의 종방향 간격은 실제 내시경의 그 방향 광학적 해상도와 비슷한 정도로서 3차원 모든 방향으로의 고해상도 이미징을 구현하였음을 보여준다. 얻어진 이미징 데이터의 3차원 영상 구현을 통해 혈관의 미세구조 및 이미징 전 삽입된 스텐트의 자세한 구조를 보였다.

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • 제1권1호
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

단일 종모드 레이저를 이용한 희토류 원자의 고분해 분광학 (High Resolution Spectroscopy for Rare Earth Atoms Using Single Longitudinal Mode Lasers)

  • 정의창;박현민;정도영;이종민
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.222-223
    • /
    • 2000
  • 희토류 (또는 란탄족) 원소들은 주기율표상에 원자 번호 57번부터 71번까지 15종의 원소들의 총칭이다. 일부 희토류 원소는 감속재를 비롯한 원자로의 재료로 사용되고 있으며, 대부분의 희토류 원자 스펙트럼은 원자력 발전소에서 사용한 연료의 폐기물 처리에 관련된 각종 연구에 이용되고 있다. 따라서 이 원소들에 대한 원자 분광학적 연구는 원자력 산업 응용 분야에서 중요하게 인식되고 있다. 특히, 레이저를 이용한 분광학적 기술은 이 원소들의 정량 분석에 있어 주성분과 비교적 적은 양 및 극미량 수준의 시료 분석에 가장 유용하게 이용되고 있다. (중략)

  • PDF

Development of an In-process Confocal Positioning System for Nanostereolithography Using Evanescent Light

  • Kajihara, Yusuke;Takeuchi, Toru;Takahashi, Satoru;Takamasu, Kiyoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.51-54
    • /
    • 2008
  • A novel stereolithography method using evanescent light has been proposed as a means to realize 100-nanometer resolution. An in-process measurement system with high accuracy has been introduced to the nanostereolithography apparatus. Specifically, an optical microscopic system was developed to monitor the exposure process and a confocal positioning system was established to improve the longitudinal positioning accuracy in the layer-by-layer process. A high-power objective lens, a tube lens, and a charge coupled device (CCD) were included in the optical microscopic system, whereas a laser, a high-power objective lens, a piezoelectric (PZT) stage, a condenser lens, a pinhole, and a photomultiplier (PMT) made up the confocal microscopic system. Two verification experiments were conducted, and the results indicated that the optical microscopic system had a horizontal resolution of 200 nm and that the confocal positioning system provided a depth resolution of 30.8 nm. These results indicate that nanostereolithography can be successfully performed with this system.