• Title/Summary/Keyword: Longitudinal Resolution

Search Result 54, Processing Time 0.026 seconds

Resolution Enhancement of Scanning Tomographic Acoustic Microscope System

  • Ko, Daesik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1E
    • /
    • pp.70-76
    • /
    • 1996
  • We proposed to use shear waves instead of longitudinal waves in a STAM (scanning tomographic acoustic microscope system) in which the specimens are solid. For any specimen with a shear modulus, mode conversion will take place at the water-solid interface. Some of the energy of the insonifying longitudinal waves in the water will convert to shear wave energy within the specimen. The shear wave energy is detectable and can be used for tomographic reconstruction. The resolution limitation of STAM depends on the available angular view and the acoustic wavelength. While wave transmission in most solid specimens is limited to about 20°for longitudinal waves, we show that it is about twice that high for shear waves. Since the wavelength of the shear wave is shorter than that of the longitudinal wave, we are able to achieve the high resolution. In order to compare the operation of a shear-wave STAM with that of the conventional longitudinal-wave STAM we have simulated tomographic reconstruction for each. Our simulation results with aluminum specimen and back-and-forth propagation algorithm showed resolution of a shear-wave STAM is better than that of a longitudinal-wave STAM.

  • PDF

A study on the Theoretical Resolution of Conoscopic Holography (Conoscopic holography의 이론적인 해상도에 대한 연구)

  • Kim, Soo-Gil;Ko, MyungSook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.1-5
    • /
    • 2014
  • Conoscopic holography, which consists of two circular polarizers and an uniaxial crystal, is incoherent holographic technology for three-dimensional display and non-contact diagnosis. In this paper, we derive the longitudinal and lateral intensities from point-source hologram made by conoscopic holography. Also, the longitudinal and lateral resolutions of conoscopic holography will be obtained from the longitudinal and lateral intensities, respectively, according to Rayleigh criterion.

Resolution Enhancement of Scanning Laser Acoustic Microscope Using Transverse Wave (횡파를 이용한 SLAM의 분해능 개선)

  • Ko, D.S.;Park, J.S.;Kim, Y.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.234-240
    • /
    • 1997
  • We studied the resolution enhancement of a novel scanning laser acoustic microscope (SLAM) using transverse waves. Mode conversion of the ultrasonic wave takes place at the liquid-solid interface and some energy of the insonifying longitudinal waves in the water will convert to transverse wave energy within the solid specimen. The resolution of SLAM depends on the size of detecting laser spot and the wavelength of the insonifying ultrasonic waves. Science the wavelength of the transverse wave is shorter than that of the longitudinal wave, we are able to achieve the high resolution by using transverse waves. In order to operate SLAM in the transverse wave mode, we made wedge for changing the incident angle. Our experimental results with model 2140 SLAM and an aluminum specimen showed higher contrast of the SLAM image in the transverse wave mode than that in the longitudinal wave mode.

  • PDF

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Evaluation of Optimal Grid Resolution for Hydrodynamic Proper Simulation (수리동역학적 모의를 위한 적정 격자해상도 산정방법)

  • Ahn, Jung-Min;Park, In-Hyeok;Lyu, Si-Wan;Hur, Young-Teck
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.1
    • /
    • pp.109-116
    • /
    • 2012
  • The effect of the grid resolution on the hydrodynamic simulation has been investigated by using CCHE2D and EFDC. Since a high resolution of the grid results in the increase of computation time, an appropriate grid resolution should be selected by considering the efficiency of simulation according to the objectives of projects. In order to understand the effect of grid resolution and determine the optimal grid resolution, several cases with different lateral grid resolutions have been simulated for the reach of Nakdong river at the confluence of Kumho river for the floods in 2006. Orthogonal curvilinear grids for the domain have been constructed from the survey products at the sections with the longitudinal interval of 20 m. Area-elevation curve and the comparison of simulated results with measured stage at the specific station have been used to check the effect of grid resolution. From the results, the existence of optimal grid resolution has been observed, which ensure both efficiency of computation and certainty of results.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

High Resolution Spectroscopy for Rare Earth Atoms Using Single Longitudinal Mode Lasers (단일 종모드 레이저를 이용한 희토류 원자의 고분해 분광학)

  • 정의창;박현민;정도영;이종민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.222-223
    • /
    • 2000
  • 희토류 (또는 란탄족) 원소들은 주기율표상에 원자 번호 57번부터 71번까지 15종의 원소들의 총칭이다. 일부 희토류 원소는 감속재를 비롯한 원자로의 재료로 사용되고 있으며, 대부분의 희토류 원자 스펙트럼은 원자력 발전소에서 사용한 연료의 폐기물 처리에 관련된 각종 연구에 이용되고 있다. 따라서 이 원소들에 대한 원자 분광학적 연구는 원자력 산업 응용 분야에서 중요하게 인식되고 있다. 특히, 레이저를 이용한 분광학적 기술은 이 원소들의 정량 분석에 있어 주성분과 비교적 적은 양 및 극미량 수준의 시료 분석에 가장 유용하게 이용되고 있다. (중략)

  • PDF

Development of an In-process Confocal Positioning System for Nanostereolithography Using Evanescent Light

  • Kajihara, Yusuke;Takeuchi, Toru;Takahashi, Satoru;Takamasu, Kiyoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.51-54
    • /
    • 2008
  • A novel stereolithography method using evanescent light has been proposed as a means to realize 100-nanometer resolution. An in-process measurement system with high accuracy has been introduced to the nanostereolithography apparatus. Specifically, an optical microscopic system was developed to monitor the exposure process and a confocal positioning system was established to improve the longitudinal positioning accuracy in the layer-by-layer process. A high-power objective lens, a tube lens, and a charge coupled device (CCD) were included in the optical microscopic system, whereas a laser, a high-power objective lens, a piezoelectric (PZT) stage, a condenser lens, a pinhole, and a photomultiplier (PMT) made up the confocal microscopic system. Two verification experiments were conducted, and the results indicated that the optical microscopic system had a horizontal resolution of 200 nm and that the confocal positioning system provided a depth resolution of 30.8 nm. These results indicate that nanostereolithography can be successfully performed with this system.