• Title/Summary/Keyword: Longitudinal Force

검색결과 441건 처리시간 0.029초

선체 용접부의 균열진전 및 피로수명예측에 관한 연구(II) (A Study of Crack Propagation and Fatigue Life Prediction on Welded Joints of Ship Structure (II))

  • 김경수;심천식;권영빈;고희승;기혁근
    • 대한조선학회논문집
    • /
    • 제45권6호
    • /
    • pp.679-687
    • /
    • 2008
  • The fatigue life of ship structure under cyclic loading condition is made up of crack initiation and propagation stages. For a welding member in ship structure, the fatigue crack propagation life is more important than the fatigue crack initiation life. To calculate precisely the fatigue crack propagation life at the critical welding location, the knowledge of the residual stress sensitivity on the fatigue strength is necessary. In this study, thermo elastic-plastic analysis was conducted in order to examine the effect of residual stress on the fatigue crack propagation life. Also the fatigue crack propagation lives considering residual stress were calculated using fatigue crack growth code, AFGROW, on the basis of fracture mechanics. AFGROW is widely used for fatigue crack growth predictions under constant and variable amplitude loading. The reliability of AFGROW on the fatigue of ship structure was confirmed by the comparison of the estimated results with the fatigue propagation test results.

에너지 소산장치를 장착한 사장교의 지진 취약도 해석 (Seismic Fragility Analysis of a Cable-stayed Bridge with Energy Dissipation Devices)

  • 박원석;김동석;최현석;고현무
    • 한국지진공학회논문집
    • /
    • 제10권3호
    • /
    • pp.1-11
    • /
    • 2006
  • 이 논문에서는 에너지 소산장치가 장착된 사장교의 지진 취약도 해석 방법을 제시하고 에너지 소산장치의 장착 및 주탑-보강형 연결 조건에 따른 지진 취약도 변화를 살펴본다. 입력지반운동, 에너지 소산장치 특성값 및 사장교 강성 모형에 확률 변수를 도입하여 불확실성을 고려하고 에너지 소산장치의 비선형 이력거동을고려하여 시간이력 해석을 수행한다. 해석결과의 회귀분석을 통한 최대 응답과 입력지반운동 세기(intensity) 사이의 관계식으로부터 취약도 해석을 위한 소요 역량(demand)을 수립한다. 역량(capacity)에 해당하는 한계상태는 주탑 하부의 전단력, 보강형의 교축방향 변위, 케이블 장력의 변동량 그리고 강주탑의 좌굴이 고려된다. 해석 예제로서 강주탑 사장교인 제 2 진도대교 모형에 대하여 취약도 해석을 수행하였다. 취약도 해석결과 에너지 소산장치의 사용을 통하여 구속 또는 비구속 연결조건시 높은 손상확률을 보이던 한계상태에 대하여 그 손상확률을 크게 줄일 수 있음을 확인하였다.

Investigations of different steel layouts on the seismic behavior of transition steel-concrete composite connections

  • Qi, Liangjie;Xue, Jianyang;Zhai, Lei
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.173-185
    • /
    • 2019
  • This article presents a comparative study of the effect of steel layouts on the seismic behavior of transition steel-concrete composite connections, both experimental and analytical investigations of concrete filled steel tube-reinforced concrete (CFST-RC) and steel reinforecd concrete-reinforced concrete (SRC-RC) structures were conducted. The steel-concrete composite connections were subjected to combined constant axial load and lateral cyclic displacements. Tests were carried out on four full-scale connections extracted from a real project engineering with different levels of axial force. The effect of steel layouts on the mechanical behavior of the transition connections was evaluated by failure modes, hysteretic behavior, backbone curves, displacement ductility, energy dissipation capacity and stiffness degradation. Test results showed that different steel layouts led to significantly different failure modes. For CFST-RC transition specimens, the circular cracks of the concrete at the RC column base was followed by steel yielding at the bottom of the CFST column. While uncoordinated deformation could be observed between SRC and RC columns in SRC-RC transition specimens, the crushing and peeling damage of unconfined concrete at the SRC column base was more serious. The existences of I-shape steel and steel tube avoided the pinching phenomenon on the hysteresis curve, which was different from the hysteresis curve of the general reinforced concrete column. The hysteresis loops were spindle-shaped, indicating excellent seismic performance for these transition composite connections. The average values of equivalent viscous damping coefficients of the four specimens are 0.123, 0.186 and 0.304 corresponding to the yielding point, peak point and ultimate point, respectively. Those values demonstrate that the transition steel-concrete composite connections have great energy dissipating capacity. Based on the experimental research, a high-fidelity ABAQUS model was established to further study the influence of concrete strength, steel grade and longitudinal reinforcement ratio on the mechanical behavior of transition composite connections.

고성능 폴리머 재질의 포스트-코어 시스템의 생역학적 거동에 대한 예비실험 (A Preliminary study of Biomechanical Behavior of High-Performance Polymer Post-Core System)

  • 이기선;김종은;김지환;이정열;신상완
    • 대한심미치과학회지
    • /
    • 제27권2호
    • /
    • pp.75-81
    • /
    • 2018
  • 본 연구의 목적은 기존의 다른 포스트-코어 재료와의 유한요소분석(FEA)의 비교를 통한 치과용 포스트-코어 재료로서의 고성능 폴리머 PEKK의 생체역학 및 장기 안전성을 평가하는 데 있다. 상악 중절치를 모델링 하였으며, 구개 표면에서 치아의 장축에 $45^{\circ}$의 각도로 50N의 반복 하중을 가했다. 전통적으로 사용 된 포스트 코어 재료와 비교하기 위해 3가지 재료 (금, 유리 섬유 및 PEKK)를 시뮬레이션하여 결과를 상호 비교 해 보았다. 상아질보다 낮은 탄성 계수를 갖는 PEKK는 종래의 포스트 코어 재료보다 비교적 치근에 유리한 응력 분포를 보여 주었다. 그러나, PEKK 포스트-코어 시스템은 금속 또는 유리 섬유 포스트-코어 시스템보다 장기간의 반복하중에 대해 타락 및 크라운 파손의 가능성이 더 높을 가능성이 있다.

냉간성형 듀플렉스계 스테인리스강(STS329FLD) 용접접합부 모재 블록전단파단 거동 (Block Shear Behavior of Cold-Formed Duplex Stainless Steel (STS329FLD) Welded Connection with Base Metal Fracture)

  • 황보경;김태수
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.157-165
    • /
    • 2019
  • Recently, lean duplex stainless steel, STS329FLD with less nickel (reduced to 0.5~1.5%) has been developed as a substitute of austenitic stainless steel (8%~10.5% nickel in STS304) and included in Korean standards (KS). This paper investigates the block shear behavior of cold-formed duplex stainless steel (STS329FLD, nominal plate thickness of 1.5mm) fillet-welded connection with base metal fracture. Main variables are weld lengths in the longitudinal and the transverse directions of applied force ranged from 20mm to 50mm. As a result, specimens failed by typical block shear facture (the combination of gross section tensile fracture and shear fracture or shear yielding) and ultimate strength of the specimens got higher with the increase of weld length. Block shear fracture strengths predicted by current design specifications (KBC2016/AISC2016 and EC3) and existing proposed equations for welded connections by Topkaya, Oosterhof & Driver and Lee et al. were compared with test strengths. KBC2016/AISC2016 and EC3 design specifications underestimated block shear strength of STS329FLD welded connections by on average 24%, 29%, respectively and Oosterhof & Driver, Topkaya and Lee et al's equations overestimated the ultimate strength of the welded connection by the range of 3% to 44%.

복열테이퍼 롤러베어링 지지특성에 따른 오버헝 회전축 시스템의 동적 거동 예측 및 접촉부 압력 해석 (Prediction of the Dynamic behavior and Contact Pressure of Overhung Rotor Systems According to the Support Characteristics of Double-row Tapered Roller Bearings)

  • 김태우;서준호;김민수;유용훈
    • Tribology and Lubricants
    • /
    • 제39권4호
    • /
    • pp.154-166
    • /
    • 2023
  • This study establishes a numerical analysis model of the finite element overhung rotor supported by a DTRB and describes the stiffness properties of the DTRB. The vibration characteristics and contact pressure of the RBR system are predicted according to the DTRB support characteristics such as the initial axial compression and roller profile. The stiffness of the DTRB significantly varies depending on the initial axial compression and external load owing to the occurrence of rollers under the no-load condition and increase in the Hertz contact force. The increase in the initial axial compression increases the rigidity of the DTRB, thereby reducing the displacement of the RBR system and simultaneously increasing the natural frequency. However, above a certain initial axial compression, the effect becomes insignificant, and an excessive increase in the initial axial compression increases the contact pressure. The roller crowning radius, which gives a curvature in the longitudinal direction of the roller, decreases the displacement of the RBR system and increases the natural frequency as the value increases. However, an increase in the crowning radius increases the edge stress, causing a negative effect in terms of the contact pressure. These results show that the DTRB support characteristics required for reducing the vibration and contact pressure of the RBR system supported by the DTRB can be designed.

Seismic control of high-speed railway bridge using S-shaped steel damping friction bearing

  • Guo, Wei;Wang, Yang;Zhai, Zhipeng;Du, Qiaodan
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.479-500
    • /
    • 2022
  • In this study, a new type of isolation bearing is proposed by combining S-shaped steel plate dampers (SSDs) with a spherical steel bearing, and the seismic control effect of a five-span standard high-speed railway bridge is investigated. The advantages of the proposed S-shaped steel damping friction bearing (SSDFB) are that it cannot only lengthen the structural periods, dissipate the seismic energy, but also prevent bridge unseating due to the restraint effectiveness of SSDs in the large relative displacements between the girders and piers. This study first presents a detailed description and working principle of the SSDFB. Then, mechanical modeling of the SSDFB was derived to fundamentally define its cyclic behavior and obtain key mechanical parameters. The numerical model of the SSDFB's critical component SSD was verified by comparing it with the experimental results. After that, parameter studies of the dimensions and number of SSDs, the friction coefficient, and the gap length of the SSDFBs were conducted. Finally, the longitudinal seismic responses of the bridge with SSDFBs were compared with the bridge with spherical bearing and spherical bearing with strengthened shear keys. The results showed that the SSDFB can not only significantly mitigate the shear force responses and residual displacement in bridge substructures but also can effectively reduce girder displacement and prevent bridge unseating, at a cost of inelastic deformation of the SSDs, which is easy to replace. In conclusion, the SSDFB is expected to be a cost-effective option with both multi-stage energy dissipation and restraint capacity, making it particularly suitable for seismic isolation application to high-speed railway bridges.

Optimization for trapezoidal combined footings: Optimal design

  • Arnulfo Lueanos-Rojas
    • Advances in concrete construction
    • /
    • 제16권1호
    • /
    • pp.21-34
    • /
    • 2023
  • This work presents a complete optimal model for trapezoidal combined footings that support a concentric load and moments around of the "X" and "Y" axes in each column to obtain the minimum area and the minimum cost. The model presented in this article considers a pressure diagram that has a linear variation (real pressure) and the equations are not limited to some cases. The classic model takes into account a concentric load and the moment around of the "X" axis (transverse axis) that is applied due to each column, i.e., the resultant force is located at the geometric center of the footing on the "Y" axis (longitudinal axis), and when the concentric load and moments around of the "X" and "Y" axes act on the footing is considered the uniform pressure applied on the contact surface of the footing, and it is the maximum pressure. Four numerical problems are presented to find the optimal design of a trapezoidal combined footing under a concentric load and moments around of the "X" and "Y" axes due to the columns: Case 1 not limited in the direction of the Y axis; Case 2 limited in the direction of the Y axis in column 1; Case 3 limited in the direction of the Y axis in column 2; Case 4 limited in the direction of the Y axis in columns 1 an 2. The complete optimal design in terms of cost optimization for the trapezoidal combined footings can be used for the rectangular combined footings considering the uniform width of the footing in the transversal direction, and also for different reinforced concrete design codes, simply by modifying the resisting capacity equations for moment, for bending shear, and for the punching shear, according to each of the codes.

프리캐스트 중간전단벽 시스템이 사용된 콘크리트 산업 시설물의 내진 및 방폭설계 (Seismic and Blast Design of Industrial Concrete Structures with Precast Intermediate Shear Wall System)

  • 이원준;김민수;김선훈;이득행
    • 한국지진공학회논문집
    • /
    • 제28권2호
    • /
    • pp.93-101
    • /
    • 2024
  • Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5Sy condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls' non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5Sy for the seismic design.

The association of perfluoroalkyl substances (PFAS) exposure and kidney function in Korean adolescents using data from Korean National Environmental Health Survey (KoNEHS) cycle 4 (2018-2020): a cross-sectional study

  • Jisuk Yun;Eun-Chul Jang;Soon-Chan Kwon;Young-Sun Min;Yong-Jin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.5.1-5.14
    • /
    • 2023
  • Background: Perfluoroalkyl substances (PFAS) are chemicals widely used in various products in everyday life. Due to its unique strong binding force, the half-life of PFAS is very long, so bioaccumulation and toxicity to the human body are long-standing concerns. In particular, effects on kidney function have recently emerged and there are no studies on the effect of PFAS on kidney function through epidemiological investigations in Korea. From 2018 to 2020, the Korean National Environmental Health Survey (KoNEHS) cycle 4, conducted an epidemiological investigation on the blood concentration of PFAS for the first time in Korea. Based on this data, the relationship between PFAS blood concentration and kidney function was analyzed for adolescents. Methods: We investigated 5 types of PFAS and their total blood concentration in 811 middle and high school students, living in Korea and included in KoNEHS cycle 4, and tried to find changes in kidney function in relation to PFAS concentration. After dividing the concentration of each of the 5 PFAS and the total concentration into quartiles, multivariable linear regression was performed to assess the correlation with kidney function. The bedside Schwartz equation was used as an indicator of kidney function. Results: As a result of multivariable linear regression, when observing a change in kidney function according to the increase in the concentration of each of the 5 PFAS and their total, a significant decrease in kidney function was confirmed in some or all quartiles. Conclusions: In this cross-sectional study of Korean adolescents based on KoNEHS data, a negative correlation between serum PFAS concentration and kidney function was found. A well-designed longitudinal study and continuous follow-up are necessary.