• Title/Summary/Keyword: Long-term experiments

Search Result 494, Processing Time 0.025 seconds

Long-Term Characteristics on Flexural Performance of Steel Fiber Reinforced Concrete Continuous Slab (강섬유보강콘크리트 연속슬래브 휨성능의 장기거동 특성)

  • Hong, Geon-Ho;Jung, Seong-Won
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.163-170
    • /
    • 2019
  • In spite of various advantages, steel fiber reinforced concrete is still limited in its use due to the insufficient research results on the structural performance and design criteria. This study evaluated the long-term behavior of the steel fiber reinforced concrete slabs by long-term loading experiments based on the short-term load bearing capacity of steel fiber reinforced concrete slabs obtained from previous studies. In this study, long-term loading experiments were carried out on Total four 2-span continuous slab specimens were tested for examining the long-term behavior of steel fiber reinforced concrete members. Long-term behavior characteristics of members were evaluated by measuring the long-term deflection, drying shrinkage, the number and width of cracks. Experimental results showed that the instant deflection of the steel fiber reinforced concrete slab is about 50% of the normal reinforced concrete slab. And, it was analyzed that the long-term deflection of the specimen using steel fiber reinforced concrete was about 10~20% lower than that of normal concrete by the long-term deflection over 100 days. In addition, the slab specimen using steel fiber reinforced concrete was evaluated to have just 70% of the number and width of cracks compared with normal concrete specimens.

The Long-term Behavior of CFT-Column (CFT 기둥의 장기거동 특성에 관한 연구)

  • 권승희;김진근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.579-582
    • /
    • 1999
  • This paper represents the results of experiments designed to investigate the time-dependent response of concrete and steel tube in circular concrete-filled steel tubes, as are deployed extensively in high-rise building construction. The experiments were performed for creep of concrete and CFT column specimens with three loading cases. The creep coefficient and specific creep(unit creep) obtained from the test results were used for estimating and comparing the time-dependent response of each case. From these analyses, it is show that CFT-column has many merits for long-term behavior.

  • PDF

Long-term Experiments of the Cooling/Cleaning on the surface of the PV Power Array (태양광발전 어레이 표면의 냉각/세정에 대한 장기 실증 실험)

  • Han, Jun-Sun;Kim, Yi-Hyun;Ji, Hee-Kwan;Yu, Sang-Phil
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.248-254
    • /
    • 2012
  • In the situation of expanding domestic solar power supply business long-term performance modeling of a proposed solar-cooling and cleaning system to increase electromotive force and light transmission is carried out to test the effectiveness of the system. To test the effectiveness of the system, the data which comparing the solar power planet installing the system to not installing at the same time is used. A difference between the utilization factor of each comparison group were recorded. Approximately from one year to two years Field Test was performed, Result of apply to cooling/cleaning technology, Each of plant by From least 7 percent up to 16 percent utilization factor increased, and the cooling / cleaning is output through improved as a result of the determined.

  • PDF

Long-Term Experiments of Cooling/Cleaning on Surface of 200-kW PV Power Array (200kW 급 태양광발전 어레이 표면의 냉각/세정에 대한 장기 실증 실험)

  • Han, Jun Sun;Jeong, Seong Dae;Yu, Sang Phil;Lee, Seong Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.971-975
    • /
    • 2013
  • In general, the solar photovoltaic power increases with higher solar insolation. However, the solar cell generation efficiency reduces because the solar cell surface is heated by solar insolation. According to advanced research, with a $1^{\circ}C$ increase in the solar cell surface temperature, the generation efficiency decreases by ~0.5%. To solve this problem, we conducted experiments in which we attempted to reduce the solar cell surface temperature using a water jet spray. In this study, we found the long-term experimental results of increases in solar power generation. The experimental results show a comparison of the site with and without cooling and cleaning equipment being installed. The results of the long-term experiments show that solar photovoltaic power generation is increased by at least 13% up to 19% with cooling and cleaning.

Case Study: Long-term Experiments on a Daily Activity Monitoring System for an Elderly Living Alone (사례 연구: 녹거노인 일상 활동 모니터링 시스템의 실제 주택에서의 장기간 실험)

  • Lee, Seon-Woo;Ok, Dae-Yoon;Jung, Phil-Hwan;Kim, Jeom-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.738-743
    • /
    • 2012
  • This paper describes analysis of long-term experiments on a monitoring system to assess the daily activities of the elderly who live alone. The developed system is composed of an in-house sensing system and a server system. The in-house sensing system installed in their own houses is a typical wireless sensor network system including three kinds of wireless sensors. The server system has a database server and an assessment server. We have installed the system into an elderly house, collected data during over two years continuously, then analyze the data. From the analysis, we could measure the energy consumption profile of three kinds of sensor nodes. The experiment shows all kinds of nodes can operate over one year with two AA-size alkaline batteries. Using a measure of reliability of the monitoring system called 'deadzone', the system has showed the failure operation for 842 hours (4.66 %) during over 18,000 hours total operation period.

Long-Term Experiments for Demonstrating Durability of a Concrete Barrier and Gas Generation in a Low-and Intermediate-Level Waste Disposal Facility

  • Kang, Myunggoo;Seo, Myunghwan;Kim, Soo-Gin;Kwon, Ki-Jung;Jung, Haeryong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.267-270
    • /
    • 2021
  • Long-term experiments have been conducted on two important safety issues: long-term durability of a concrete barrier with the steel reinforcements and gas generation from low-and intermediate-level wastes in an underground research tunnel of a radioactive waste disposal facility. The gas generation and microbial communities were monitored from waste packages (200 L and 320 L) containing simulated dry active wastes. In the concrete experiment, corrosion sensors were installed on the steel reinforcements which were embedded 10 cm below the surface of concrete in a concrete mock-up, and groundwater was fed into the mock-up at a pressure of 2.1 bars to accelerate groundwater infiltration. No clear evidence was observed with respect to corrosion initiation of the steel reinforcement for 4 years of operation. This is attributed to the high integrity and low hydraulic conductivity of the concrete. In the gas generation experiment, significant levels of gas generation were not measured for 4 years. These experiments are expected to be conducted for a period of more than 10 years.

Evaluation of Shelf-life of Bojungikgi-tang by Long-term Storage Test (장기보존시험에 따른 보중익기탕 전탕팩의 유통기한 평가)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Kim, Seong-Sil;Lim, Soon-Hee;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.44 no.2
    • /
    • pp.200-208
    • /
    • 2013
  • The aim of this study was to evaluate the shelf-life of Bojungikgi-tang (Buzhongyiqi-tang in Chinese) by long-term storage test. Experiments were performed to evaluate the stability such as the selected physicochemical, pH, identification, heavy metal, microbiological experiment, and amount of marker compounds under a long-term storage test of Bojungikgi-tang decoction. The significant change was not showed in pH, heavy metal, microbiological, and identification test based on long-term storage test. Furthermore, the HPLC analysis was performed for the determinations of liquiritin, glycyrrhizin, nodakenin, and hesperidin in Bojungikgi-tang by long-term storage test. We were calculated shelf-life of Bojungikgi-tang decoction based on the amount change of four constituents. Consequently, Shelf-life by four compounds at room temperature was predicted 23 month. The suggested shelf-life would be helpful on the storage and distribution of herbal medicine.

Establishment of Shelf-life of Ssanghwa-tang by Long-term Storage Test (장기보존시험에 따른 쌍화탕의 유통기한 설정)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Lim, Soon-Hee;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.3
    • /
    • pp.257-264
    • /
    • 2012
  • The purpose of this study was to estimate the shelf-life of Ssanghwa-tang by long-term storage test. Experiments were conducted to evaluate the stability such as the selected physicochemical, pH, identification, heavy metal, microbiological experiment under a long-term storage test of Ssanghwa-tang. The significant change was not showed in pH, heavy metal, microbiological, identification test and quantitative analysis based on long-term storage test. The contents of albiflorin, paeoniflorin, cinnamic acid, liquiritin, and glycyrrhizin in long-term storage test were 66.8-93.1 ${\mu}g/mL$, 429.0-495.0 ${\mu}g/mL$, 3.8-4.4 ${\mu}g/mL$, 32.0-38.1 ${\mu}g/mL$, and 66.8-71.7 ${\mu}g/mL$, respectively. Shelf-lifes by 5 compounds about 3 lots at room temperature were predicted 21-37, 14-21, and 16-72 months, respectively. The suggested shelf-life would be helpful on the storage and distribution of herbal medicine.

In vitro Retention of Antimicrobial Activity of Ciprofloxacin-incorporated Central Venous Catheters

  • Jeon, Sung-Min;Kim, Mal-Nam
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.175-182
    • /
    • 2007
  • In vitro ciprofloxacin (CFX)-release study and bioassay using microorganisms were performed to estimate the retention of the antimicrobial activity of the CFX-incorporated central venous catheters (CFX-CVCs). The release experiments were carried out under the optional CFX-release conditions to mimic the in vivo environment. The release of CFX experienced an initial burst followed by a slow and steady matrix-diffusion controlled release. The 1.0CP (polyurethane catheter containing 1.0% (w/w) of CFX) under dynamic condition showed a near zero-order CFX release profile, which is beneficial for the long-tenn antimicrobial activity. The modified Kirby-Bauer method was performed employing S. aureus and E. coli to evaluate the retention of antimicrobial activity of the catheters retrieved from the release experiments. The 1.0CP showed the long-term antimicrobial activity (${\geq}\;21$ days) against both S. aureus and E. coli. These results indicate that 1.0CP is useful as a long-tenn indwelling CVC.

  • PDF

A Long-term Capacity Reservation Contract (장기 용량예약 계약)

  • Kim Yong Chan;Kim Jong Soo;Kang Woo Seok
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.30 no.2
    • /
    • pp.105-115
    • /
    • 2005
  • By committing to a long-term replenishment contract, buyers can purchase a product at a lower price from a supplier who is less pressured to find new customers due to the long-term contract and can charge a discounted price. We develop an analytical model from the buyer's perspective to investigate a capacity reservation contract. We are considering the system with a single supplier and a buyer. The buyer can purchases any desired amount from a spot market at a higher price in addition to the contracted amount. For such a system, we propose an algorithm to derive the optimal contract terms. The result of computational experiments shows that the algorithm finds the global optimum solution in a resonable amount of time.