• Title/Summary/Keyword: Long-term durability

Search Result 502, Processing Time 0.023 seconds

Twenty-one Year Experience with Right Ventricle to Pulmonary Artery Conduit Interposition (우심실-폐동맥 간 도관 이식술의 21년간의 경험)

  • Kwak, Jae-Gun;Yoo, Jae-Suk;Kim, Yong-Jin;Kim, Woong-Han;Lee, Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.417-422
    • /
    • 2008
  • Background: The aim of this study is to evaluate the long term results of creating various right ventricle to pulmonary artery conduits for treating complex congenital heart disease. Material and Method: Between June 1986 and July 2006, we retrospectively reviewed 245 patients who underwent reconstruction of the right ventricular outflow tract with various kinds of conduits. 410 operations were done in 245 patients, the mean age at operation was $3.2{\pm}4.9$ years (range: 7 days$\sim$45 years) and the mean body weight was $12.5{\pm}8.7\;kg$ (range: $2.4\sim76.3\;kg$). Result: We used the following conduits: Polystan conduit, Shelhigh conduit, Carpenter-Edward conduit, Dacron graft with an artificial valve, valveless Gore Tex vascular graft, homograft and hand-made bovine or autologous pericardial conduit. The mean follow up duration was $6.3{\pm}5.2$ years. Redo operation for RV-PA conduit dysfunction was performed in 131 patients, a second redo was done in 31 and a third redo was done in 3. The reoperation free rates were 67.3%, 48.5% and 39.4% for 5 years, 10 years and 15 years, respectively. The homograft showed the best durability, followed by the Dacron graft with artificial valve and the Carpentier-Edward conduit. The larger sized conduit showed better durability. Conclusion: The homograft showed lowest reoperation rate and a smaller size of conduit showed the highest reoperation rate. The reoperation rate for the RV-PA conduit was about 35% at 5 years, so it is mandatory to develop the more durable conduit for RV outflow.

THE EFFECT OF PRIMING ETCHED DENTIN WITH SOLVENT ON THE MICROTENSILE BOND STRENGTH OF HYDROPHOBIC DENTIN ADHESIVE (산 부식된 상아질에 대한 용매를 이용한 프라이밍이 소수성 상아질 접착제의 미세인장접착강도에 미치는 영향)

  • Park, Eun-Sook;Bae, Ji-Hyun;Kim, Jong-Soon;Kim, Jae-Hoon;Lee, In-Bog;Kim, Chang-Keun;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Deterioration of long-term dentin adhesion durability is thought to occur by hydrolytic degradation within hydrophilic domains of the adhesive and hybrid layers. This study investigated the hypothesis that priming the collagen network with an organic solvent displace water without collapse and thereby obtain good bond strength with an adhesive made of hydrophobic monomers and organic solvents. Three experimental adhesives were prepared by dissolving two hydrophobic monomers, bisphenol-A-glycidylmethacrylate (Bis-GMA) and triethyleneglycol dimethacrylate (TEGDMA), into acetone, ethanol or methanol. After an etching and rinsing procedure, the adhesives were applied onto either wet dentin surfaces (wet bonding) or dentin surfaces primed with the same solvent (solvent-primed bonding). Microtensile bond strength (MTBS) was measured at 48 hrs, 1 month and after 10,000 times of thermocycles. The bonded interfaces were evaluated using a scanning electron microscope (SEM). Regardless of bonding protocols, well-developed hybrid layers were observed at the bonded interface in most specimens. The highest mean MTBS was observed in the adhesive containing ethanol at 48 hrs. With solvent-primed bonding, increased MTBS tendencies were seen with thermo cycling in the adhesives containing ethanol or methanol. However, in the case of wet bonding, no increase in MTBS was observed with aging.

Analysis of Market and Technology Status of Major Agricultural Machinery (Tractor, Combine Harvester and Rice Transplanter) (핵심 농기계(트랙터, 콤바인 및 이앙기) 시장 및 기술 현황 분석)

  • Hong, Sungha;Choi, Kyu-hong
    • Journal of the Korean Society of International Agriculture
    • /
    • v.31 no.1
    • /
    • pp.8-16
    • /
    • 2019
  • Alternatives for increasing the competitiveness of locally manufactured agricultural machinery in domestic and foreign markets has been proposed. This was done by analyzing the major agricultural machinery's price and market share as well as their performance and quality. In the Korean domestic market, the market share of Japanese agricultural machinery has been identified to be 14.5% for tractors, 31.1% for combine harvesters, and 35.8% for rice transplanters, and on track for further increase. Japanese manufacturers' domestic patent shares are 58.5% for tractors, 79.9% for combine harvesters, and 69.8% for rice transplanters, showing the dire need for Korean domestic firms to expand their technological rights. To strengthen the industrial competitiveness of agricultural machinery, therefore, researches that develop the fundamental and elemental technology to reduce the frequency of breakdown should be needed in the short term. To achieve this, it is imperative to establish technology roadmap, promote greater cooperation between academia and industry, and systematically increase research funding. In addition, as a long-term solution for enhancing the competitiveness, an establishment of Agricultural Equipment Technology Institute is strongly recommended to systematically support R&D for developing core technologies, particularly high-quality components that guarantee durability and quality.

Prediction of field failure rate using data mining in the Automotive semiconductor (데이터 마이닝 기법을 이용한 차량용 반도체의 불량률 예측 연구)

  • Yun, Gyungsik;Jung, Hee-Won;Park, Seungbum
    • Journal of Technology Innovation
    • /
    • v.26 no.3
    • /
    • pp.37-68
    • /
    • 2018
  • Since the 20th century, automobiles, which are the most common means of transportation, have been evolving as the use of electronic control devices and automotive semiconductors increases dramatically. Automotive semiconductors are a key component in automotive electronic control devices and are used to provide stability, efficiency of fuel use, and stability of operation to consumers. For example, automotive semiconductors include engines control, technologies for managing electric motors, transmission control units, hybrid vehicle control, start/stop systems, electronic motor control, automotive radar and LIDAR, smart head lamps, head-up displays, lane keeping systems. As such, semiconductors are being applied to almost all electronic control devices that make up an automobile, and they are creating more effects than simply combining mechanical devices. Since automotive semiconductors have a high data rate basically, a microprocessor unit is being used instead of a micro control unit. For example, semiconductors based on ARM processors are being used in telematics, audio/video multi-medias and navigation. Automotive semiconductors require characteristics such as high reliability, durability and long-term supply, considering the period of use of the automobile for more than 10 years. The reliability of automotive semiconductors is directly linked to the safety of automobiles. The semiconductor industry uses JEDEC and AEC standards to evaluate the reliability of automotive semiconductors. In addition, the life expectancy of the product is estimated at the early stage of development and at the early stage of mass production by using the reliability test method and results that are presented as standard in the automobile industry. However, there are limitations in predicting the failure rate caused by various parameters such as customer's various conditions of use and usage time. To overcome these limitations, much research has been done in academia and industry. Among them, researches using data mining techniques have been carried out in many semiconductor fields, but application and research on automotive semiconductors have not yet been studied. In this regard, this study investigates the relationship between data generated during semiconductor assembly and package test process by using data mining technique, and uses data mining technique suitable for predicting potential failure rate using customer bad data.

Long Term Results of Valve Replacement with the St. Jude Medical Heart Valves: Thirteen Year Experience (St. Jude 기계판막을 이용한 판막 치환술의 장기 성적)

  • Kim, Chang-Gon;Gu, Ja-Hong;Jo, Jung-Gu;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.891-898
    • /
    • 1997
  • Between May 1984 and January 1996, 130 patients were replaced cardiac valve using 150 St. Jude Medical prosthetic valves(42 aortic, 68 mitral, 20 aortic and mitral valve replycements). Follow-up was 97.6% complete. The early mortality rate was 5.4%, and late mortality rate was 4.9%. The valve-related late mortality rate was 3.3%. Of late complications, there were 6 anticoagulant related hemorrhages, 4 thromboembolisms and 1 paravalvular leakage. Linearized rates of late complication and valve-related late mortality were as follows: total late complications, .1.68o per patient-year: anticoagulant related hemorrhages, 0.92% per patient-year: thromboembolism, 0.61% per patient-year: paravalvular leakage, 0.15% per patient-year: reoperation, 0.15% per patient-year: and valve-related late mortalities, 0.61% per patient-year. Actuar al event free rate at 10 years was 87.4 $\pm$ 3.2%. The overall actuarial survival rate was 90.4$\pm$2.7% at 5 years, 87.5$\pm$3.3% at 10 years. Ninety eight percent of the survivors were in the New York Heart Association functional class I or II at the end of follow-up. There was significant improvement of cardiothoracic ratio. In conclusion, this study suggests the excellent durability of the St. Jude Medical Heart valve and remarkable functional benefit for the majority of the patients. However, prosthesisrelated complications are still common. Outcome is strongly related to the patient's preoperative cardiac condition and to the adequacy of anticoagulation control.

  • PDF

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Aortic Valvuloplasty Using Leaflet Extension Technique (판막첨 연장술을 이용한 대동맥판막 성형술의 중기성적 평가)

  • Ahn, Hyuk;Kim, Hyun-jo
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.656-662
    • /
    • 1997
  • Aortic valvuloplasty has recently gained attention as an attractive alternative procedure for aortic valvular disease. Between March 1995 to August 1996, 14 patients with pure aortic regurgitation(AR) underwent aortic alvuloplasty using leaflet extension with glutaraldehydepreserved autologous pericardium. There were 11 males and 3 females, and the mean age was 34.8 $\pm$ 15.3 years. Preoperative echocardiography and cardiac catheterization revealed that the degree of AR was mean 3.4$\pm$0.65, and more than moderate degree of mitral regurgitation(MR) were detected in 4 patients. In 12 patients, 3 leaflets were extended and in another 2 patients only one deformed leaflet was extended. Concomitant mitral valvuloplasty (MVP) was performed in 4 patients. The competency of the aortic valve after completion of repair was evaluated by the transesophageal echocardiography in operating theater, and there was no aortic and mitral stenosis or regurgitation. In an early postoperative echocardiography, trivial AR was detected in 3 patients and mild MR in 1 patient. The end-systolic and end-diastolic dimensions of the left ventricle were decreased significantly(p<0.05) as compared with those of preoperative values. T ere was no mortality and no significant postoperative complication encountered. Late complication developed in 2 patients during the follow-up period(mean 7.9$\pm$ 5.9 months). One patient underwent AVR on postoperative 7th month due to endocarditis, and the another patient with Behcet's disease underwent Ross operation at postoperative 4th month. In conclusion, AVP of leaflet extension technique offers an excellent early clinical result and represents a good alterna!ivy surgical treatment for the pure AR especially in young age group, although long-term follow-up is necessary to determine the durability of glutaraldehyde-preserved autologous pericardium as a valve leaflet.

  • PDF

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

Efficacy of Lamivudine Therapy for Chronic Hepatitis B in Children (소아 만성 B형 간염 환아에서 라미부딘의 치료 효과)

  • Lee, Eun-Hye;Jang, Joo-Young;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.130-136
    • /
    • 2008
  • Purpose: Lamivudine is known to be effective for the treatment of chronic hepatitis B in adults. However, data on lamivudine therapy in pediatrics is limited. The aim of this study was to evaluate the efficacy and durability of lamivudine therapy for chronic hepatitis B in Korean children. Methods: A total of 44 children (27 males and 17 females, ages 6 months to 14.8 years, mean age 6.7 years) with chronic hepatitis B who received lamivudine (3 mg/kg/day, max 100 mg) for at least 12 months were enrolled. We evaluated the serum AST, ALT and serological HBV markers (HBsAg and anti-HBs, HBeAg and anti HBe, and HBV DNA) periodically. Predictive three year cumulative seroconversion rates were obtained using the Kaplan-Meier method. Results: Twenty one (48%) of 44 children achieved seroconversion of HBeAg by three years, while 23 (42%) children did not. HBV DNA was cleared in 34 (77%) children and the serum ALT levels were normalized in 41 children (93%). The three year cumulative seroconversion rates were 60% for HBeAg, and the clearance rates were 76% for HBV DNA. Eighteen children who discontinued lamivudine after HBeAg seroconversion maintained the therapeutic response for three years (treatment duration 13~58 months mean 24 months). Viral breakthrough developed in 12 children (27%) during the therapy and the YMDD mutation was documented in 11 children (25%). The mean duration for the development of a mutation was 22.7 months. Loss of HBsAg occurred in 6 children (14%). The pretreatment ALT levels were higher in responders; however, the differences were not statistically significant (p>0.05). Conclusion: The results of this study showed that lamivudine treatment had a favorable effect and durable therapeutic response in children with chronic hepatitis B. Long term follow-up and alternative therapy are warranted for those patients who do not respond to this treatment.

  • PDF

Twenty-year Experience of Mitral Valve Replacement with the St. Jude Medical Mechanical Valve Prosthesis (St. Jude 기계 판막을 이용한 승모판막 치환술의 20년 장기성적)

  • Seo Yeon-Ho;Kim Kong-Soo;Jo Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.527-533
    • /
    • 2006
  • Background: A retrospective study was conducted to analyze the results of St. Jude Medical mitral valve replacement at the Chonbuk National University Hospital since the initial implant in May 1984. Material and Method: Between May of 1984 and December of 1996, 95 patients underwent MVR with the St. Jude Medical mechanical valve prosthesis at Department of Medical Science of Chonbuk National University Hospital and follow-up ended in May of 2004. Result: Age ranged from 19 to 69 years. Follow-up (mean${\pm}$standard deviation) averaged $10.6{\pm}4.2\;year$. Thirty-day operative mortality was 4.2% (4/95). Nine late deaths have occurred and actuarial survival was $90.5{\pm}3.0%,\;87.9{\pm}3.4%\;and\;83.2{\pm}4.6%$ at 5, 10 and 20 years, respectively. Probability of freedom from valve-rotated death was $95.5{\pm}2.1%,\;94.3{\pm}2.4%\;and\;91.0{\pm}3.9%$ at 5, 10 and 20 years, respectively. Seven patients have sustained thromboembolic events (1,05%/patient-year). Fifteen patients had anticoagulation related hemorrhage (3.56%/patient-year). There was no structural valve deterioration. Probability of freedom from all complications was $82.0{\pm}3.9%,\;71.3{\pm}4.8%\;and\;42.4{\pm}10.5%$ at 5, 10 and 20 years, respectively. Conclusion: We confirm the effective and excellent durability of the St. Jude Medical prosthesis in the mitral position with a low event rate at long-term follow-up. It also demonstrates the commonly encountered practical difficulty of adjusting the anti-coagulation protocol in patients with prosthetic mitral valves.