• Title/Summary/Keyword: Long-term durability

Search Result 502, Processing Time 0.027 seconds

Prediction Equation for Chloride Diffusion in Concrete Containing GGBFS Based on 2-Year Cured Results (2년 양생 실험결과를 이용한 고로슬래그 미분말 콘크리트의 염화물 확산 예측식)

  • Yoon, Yong-Sik;Cho, Sung-Jun;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.1-9
    • /
    • 2019
  • GGBFS(Ground Granulated Blast Furnace Slag), one of the representative concrete mineral admixtures, improves the long-term durability and engineering performance of concrete by latent hydraulic activity. In this study, considering 3 levels of W/B(0.37, 0.42, 0.47) and GGBFS replacement ratio(0 %, 30 %, 50 %), durability performances for chloride attack are evaluated, and equations which predict behavior of accelerated chloride diffusion are proposed. Also, the relationship between accelerated chloride diffusion coefficient and passed charge is evaluated. In target curing day, accelerated chloride diffusion tests(Tang's method, ASTM C 1202) and compressive strength(KS F 2405) are performed. In the 730 day's results of accelerated chloride diffusion coefficient, GGBFS concrete has up to 28 % of decreasing ratio compared to OPC concrete, and in those of passed charge, GGBFS concrete has up to 29 % of decreasing ratio compared to OPC concrete. Also, it is deemed that the impact of variation of W/B is less in GGBFS concrete than in OPC concrete. The equations which predict accelerated chloride diffusion coefficient and passed charge are drawn, based on the characteristics of mixture and test results. The equation which predicts passed charge shows slightly higher coefficient of determination than that which predicts accelerated chloride diffusion coefficient.

Long Term Results of Rastelli Operation with a Mechanical Valve (기계 판막을 이용한 라스텔리 수술의 장기 성적)

  • Choi, Se-Hoon;Kim, Kwan-Chang;Kwak, Jae-Gun;Kim, Chang-Young;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.900-905
    • /
    • 2006
  • Background: Homografts and bioprostheses are most commonly used for Rastelli operation in congenital heart disease, but the limited durability is responsible for multiple reoperations associated with increased morbidity This study evaluated long-term results after Rastelli operation with a mechanical valved conduit. Material and Method: A total of 20 patients underwent Rastelli operation with mechanical valved conduit from January 1990 to July 1992. Operative mortality was 1 of 20 patients, and a retrospective review of 19 patients(10 males, 9 females) was done. Initial diagnosis was congenitally corrected transposition of great arteries(cc-TGA, n=4), complete TGA (n=2), ventricular septal defect with pulmonary atresia(VSD with PA, n=9), truncus arteriosus(n=2), double outlet right ventricle with pulmonary stenosis(DORV with PS, n=2). The mean age at Rastelli operation was $4.6{\pm}3.4$ years, and mean follow-up period was $12.8{\pm}2.7$ years. Patients underwent Rastelli opearation using 16 CarboMedics mechanical valve, and 3 Bjork-Shiley mechanical valve($17{\pm}2$ mm). Result: There were 15 reoperations for failed mechanical valved conduit. The freedom from reoperation at 5 and 10 years was 53% and 37%. Most patients were received oral anticoagulation with warfarin, and maintained the international normalized ratio(INR) of 1.5 to 2.0. There was no anticoagulation or thromboembolism related complication. There was a significant difference in the causes of a conduit failure between early(within 3 years) and late(after 3 years) failure groups. The six patients reported early prosthetic valve failure, mainly due to valvular dysfunction by thrombosis or pannus formation. The other nine patients reported late prosthetic valve failure, mainly due to dacron conduit stenosis at anastomosis sites, whereas their valvar motion was normal except 1 patient. Conclusion: To avoid early prosthetic valve failure, strict anticoagulation therapy would be helpful. About the late development of obstructive intimal fibrocalcific peels within the Dacron conduit, an improvement of conduit material is necessary to reduce late prosthetic valve failure. In selected patients, the long term results were satisfactory.

Evaluation of Chloride Diffusion Behavior and Analysis of Probabilistic Service Life in Long Term Aged GGBFS Concrete (장기 재령 GGBFS 콘크리트의 염화물 확산 거동 평가 및 확률론적 염해 내구수명 해석)

  • Yoon, Yong-Sik;Kim, Tae-Hoon;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • In this study, three levels of W/B(Water to Binder) ratio (0.37, 0.42, 0.47) and substitution ratio of GGBFS (Ground Granulated Blast Furnace Slag) rate (0 %, 30 %, 50 %) were considered to perform RCPT (Rapid Chloride Diffusion Test) at the 1,095 aged day. Accelerated chloride diffusion coefficient and passed charge of each concrete mixture were assessed according to Tang's method and ASTM C 1202, and improving behaviors of durability performance with increasing aged days are analyzed based on the test results of previous aged days from the preceding study. As the age of concrete increases, the passed charge and diffusion coefficient have been significantly reduced, and especially the concrete specimens containing GGBFS showed a significantly more reduction than OPC(Ordinary Portland Cement) concrete specimen by latent hydraulic activity. In the case of OPC concrete's results of passed charge, at the 1,095 days, two of them were still in the "Moderate" class. So, if only OPC is used as the binder of concrete, the resistance performance for chloride attack is weak. In this study, the time-parameters (m) were derived based on the results of the accelerated chloride diffusion coefficient, and the deterministic and probabilistic analysis for service life were performed by assuming the design variable as a probability function. For probabilistic service life analysis, durability failure probabilities were calculated using Monte Carlo Simulation (MCS) to evaluate service life. The service life of probabilistic method were lower than that of deterministic method, since the target value of PDF (Probability of Durability Failure) was set very low at 10 %. If the target value of PDF suitable for the purpose of using structure can be set and proper variability can be considered for each design variable, it is believed that more economical durability design can be made.

Cyclic Oxidation Behavior of Vacuum Plasma Sprayed NiCoCrAlY Overlay Coatings (진공 플라즈마 용사법을 통해 형성된 NiCoCrAlY 오버레이 코팅의 반복 산화 거동)

  • Yoo, Yeon Woo;Nam, Uk Hee;Park, Hunkwan;Park, Youngjin;Lee, Sunghun;Byon, Eungsun
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.6
    • /
    • pp.283-288
    • /
    • 2019
  • MCrAlY overaly coatings are used as oxidation barrier coatings to prevent degradation of the underlying substrate in high temperature and oxidizing environment of the hot section of gas turbines. Therefore, oxidation resistance in high temperature is important property of MCrAlY coatings. Also, coefficients of thermal expansion (CTE) of MCrAlY have middle value of that of Ni-based superalloys and oxides, which have the effect of preventing the delamination of the surface oxides. Cyclic oxidation test is one of the most useful methods for evaluating the high temperature durability of coatings used in gas turbines. In this study, NiCoCrAlY overlay coatings were formed on Inconel 792(IN 792) substrates by vacuum plasma spraying process. Vacuum plasma sprayed NiCoCrAlY coatings and IN 792 susbstrates were exposed to 1000℃ one-hour cyclic oxidation environment. NiCoCrAlY coatings showed lower weight gain in short-term oxidation. In long-term oxidation, IN 792 substrates showed higher weight loss due to delamination of surface oxide but NiCoCrAlY coatings showed lower weight loss. X-ray diffraction (XRD) analysis showed α-Al2O3 and NiCr2O4 was formed during the cyclic oxidation test. Through cross-section observation using scanning electron microscopy (SEM) and electron back scatter diffraction (EBSD) analysis, thermally grown oxide (TGO) layer composed of α-Al2O3 and NiCr2O4 was formed and the thickness of TGO increased during 1000℃ cyclic oxidation test. β phase in upper side of NiCoCrAlY coating was depleted due to oxidation of Al and outer beta depletion zone thickness also increased as the cyclic oxidation time increased.

Ecological Green Roofs in Germany

  • Kohler, Manfred
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.8-16
    • /
    • 2004
  • The industrialization of central Europe more than 100 ago marked the beginning of densely concentrated buildings in quickly growing cities. A cheap type of roofing material of that time was tar. But it was dangerous because it was high inflammable. Then some roofer had a splendid idea. They used sandy material as a final layer atop the impermeable tar layer. These roofs were much more fire resistant than the typical roofs. In this sandy layer some plant species began to grow spontaneously. This was the beginning of the green roof history of modern Europe. A number of these green roofs survived both world wars. In the early 80's in Berlin alone, 50 such buildings existed and they continued to be waterproof until the present day. Since the 1992 Earth Summit of 1992 in Rio de Janeiro(http://www.johannesburgsummit.org/html/basic_info/unced.html) the term "sustainable development" became of central interest of urban designers. In city regions green roofs had become synonymous with this term. With a small investment, long-lasting roofs can be created. Further back in history, more exciting examples of green roofs can be found. The hanging gardens of antiquity are well-known. There are also green roofs built as insulation against cold and heat all over the world. For over 20 years, roof greening in central Europe has been closely examined for various reasons. Roof greening touches several different disciplines. Of primary interest is the durability of the roofs. But ecologists are also interested in green roofs, for instance in biodiversity research. The beneficial effect of greening on water proofing was also proven. For some time, the issue of fire protection was investigated. According to tests, green roofs received a harsh careful rating. Their fire protective property is considered similar to that of tile roofs. Another recent impulse for the green roof movement in Germany has come from the evident improvement of storm water retention and the reduced burden on the sewer system. The question of whether and how much energy green roofs can save has become an urgent question. The state of the research and also various open questions from a central European point of view will be discussed in the context of international collaboration. Apart from academic considerations, those who involve themselves in this issue take a predominantly positive view of the numerous existing green roofs in Germany. In some cities, green roofs are the typical construction technique for new buildings. A few outstanding examples will conclude this review. In Germany, about 20 companies, some of which operate internationally, specialize in green roof consulting. Learning from each other in an open-ended way with respect to different construction techniques and applications in various climatic regions can only be accomplished through such international collaboration as is taking place here.

Technology Development of Entry-Level MiC Smart Photovoltaic System based on SOC (SoC 기반 보급형 MiC 스마트 태양광발전시스템 기술개발)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.129-134
    • /
    • 2020
  • Moisture infiltration inside the solar cell module, filling of EVA sheet, melting of the frame seal, and deterioration of power generation performance in the module one year after installation are occurring. Whitening phenomenon, electrode corrosion phenomenon, and dielectric breakdown phenomenon are appearing in solar cell module installed in Korea before 5-7 years, leading to deterioration of power generation performance, and big problems for long-term reliability and long life technology are emerging. Therefore, in order to solve these problems, the development of a micro inverter (MiCrco Inverter Converter, MiC) including the function of securing the durability of the solar cell module and monitoring the aging progress and the solar cell based on the monitoring data from the MiC smart monitoring programs have been proposed to determine the aging of modules. In addition, in order to become a highly efficient solar smart monitoring system through systematic operation management through IT convergence with MiC that has enhanced monitoring function of solar cell module, SoC(System On Chip) in micro inverter is the environment for solar cell module. There is a demand for functions that can detect information in a complex manner and perform communication and control when necessary. Based on these requirements, this paper aims to develop SoC-based low-cost MiC smart photovoltaic system technology.

Comparative Study on the Flexural Performance of Concrete Reinforced with Polypropylene and Steel Fibers (폴리프로필렌 및 강섬유 보강콘크리트의 휨 성능에 관한 비교 연구)

  • Cho, Baiksoon;Lee, Jong-Han;Back, Sung Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1677-1685
    • /
    • 2014
  • Short discrete fibers compounded with concrete can enhance the tensile resistance and ductility of concrete. Recently, the effectiveness of the reinforcement has increased according to the increasing length of steel fiber. However, the lengthening of steel fiber requires reducing the ratio of the fiber content to remain the workability and quality of concrete. Thus, the present study evaluated the flexural performance of fiber reinforced concrete with less than l.0% fiber volume ratios of steel fiber, 30mm and 60mm long, and polypropylene fiber, being evaluated as a good reinforcing material with chemical stability, long-term durability, and cost effectiveness. Concrete with more than 0.25% steel and 0.5% polypropylene fibers improved the brittle failure of concrete after reaching cracking strength. Concrete reinforced with polypropylene exhibited deflection-softening behavior, but that with more than 0.5% polypropylene delayed stress reduction and recovered flexural strength by 60 to 80% after cracking strength. In conclusion, concrete reinforced with more than 0.75% polypropylene could improve structural flexural performance. In particular, energy absorption capacity of reinforced concrete with 1.0% polypropylene fiber was similar to that with 0.5% and 0.7% steel fibers.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Midterm Results of Aortic Valve Replacement Using Tissue Valve (조직판막을 이용한 대동맥판막치환술의 중기성적)

  • Moon, Duk-Hwan;Lee, Jae-Won;Kim, Yun-Seok;Cho, Won-Chul;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.627-634
    • /
    • 2010
  • Background: The durability of the tissue valve is important in choice between a mechanical valve and a tissue valve in cardiac surgery. We studied the mid-term results of tissue valve in the aortic position. Material and Method: The subjects were 380 patients who had undergone aortic prosthesis replacement between May 1990 and March 2009. We retrospectively analyzed hospital and outpatient records: the mean age was $69{\pm}9$ years; the male to female ratio was 227 : 162; and the mean follow-up duration was $46.7{\pm}40.8$ months (range 0~196 months). Result: 389 surgical cases in total had been taken with 380 patients. Early death occurred in 15 patients (3.9%). Overall survival rate at 1, 5 and 10 years were 92.3%, 78.1% and 54.2% respectively. Freedom from reoperation at 1, 5 and 10 years were 98.4%, 97.1% and 91.7% respectively. Freedom from structural valvular deterioration at 1, 5 and 10 years were 96.1%, 92.3% and 88.0% respectively. In the multivariate analysis of preoperative risk factors, young age (p<0.001) was significant risk factor for reoperation. High peak velocity in the postoperative period (p=0.034) and young age (p=0.029) were significant risk factors for structural valvular deterioration. Old age (p=0.001), long bypass time (p=0.035), concomitant coronary artery bypass graft surgery (p=0.003) and preoperative low left ventricular ejection fraction (p=0.003) were significant factors for early mortality. Preoperative estimated glomerular filtration rate (< 60 mL/min) (p=0.025) and persistent left ventricular hypertrophy (p=0.032) were the risk factors for late mortality. Conclusion: This study showed that the freedom from reoperation and the freedom from structural valvular deterioration in aortic tissue valve replacement were acceptable. It will be necessary to conduct further studies with long-term follow-up and more patients.

Tissue Failure of the Low-Profile lonescu-Shiley Pericardial Valve in Mitral Position (승모판에서의 단고형 이오네스큐판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.670-676
    • /
    • 1997
  • The structural failure of the glutaraldehyde-treated xenograft valves has been the primary concern about the limited durability as predicted from the begimling of clinical use, and long-term follow-up has shown a significant incidence of primary tissue failure(PTF) from both biological and mechanical reasons. Twenty-seven patients with the low-profile lonescu-Shiley valves explanted from mitral position for PTF(Group III) were studied on the patient characteristics and valve pathology, and the results were compared with the matched observations of the Haycock(Group I) and of the standard-profile lonesiu-Shiley valves(Group II). Patients were aged 16 to 56 years(mean, 38.0$\pm$ 11.0 years), and the size of the failed mitral bioprosthesis was 30.8$\pm$ 1.3 mm. The hemodynamic consequences were stenosis in 29.6%, insufficiency in 44.4%, mixed steno-insufficiency in 14.8%, together with normal function for the rest of patients of prophylactic re-replacement. Pathology revealed calcification with or without tissue damage in 63.0% and tissue damage with or without calcification in 58.l%, in contrast with the observations of predominant tissue damage(76.8%) over calcification in Group I and of calcification(76.1%) over tissue damage in group II. Although dystrophic calcification has long and repeatedly dealt with patient's young age as a determinant of valve durability, such a characteristic evidence was not reached even in patients with calcified valves. Moreover, the prolonged explantation p riods from the studied on the previous report suggested strongly yet possibly evolving destructive processes among the valves in the remaining patients, and awaits further follow-up. In conclusion, PTF of the xenograft valves seems to result from more complicated biologic and metabolic reasons as well as more complex mecharical factors than the reported, and newer generation prostheses, with tissue preservation with glutaraldehyde, do not likely to provide decisive improvement in the occurrence of structural failurebioprostheses is generally limited to the highly aged.

  • PDF