• Title/Summary/Keyword: Long-term deterioration

Search Result 328, Processing Time 0.027 seconds

Material and Deterioration Characteristic Analysis for Inscribed Stones of Naksan Mountain Area of the Hanyangdoseong(Seoul City Wall), Korea

  • Lee, Myeong Seong;Kim, Yuri;Choie, Myoungju;Yoo, Ji Hyun;Ahn, Yu Bin
    • Journal of Conservation Science
    • /
    • v.36 no.1
    • /
    • pp.60-72
    • /
    • 2020
  • The Inscribed stones of Hanyangdoseong has been weathered for a long time because of external environment and living organisms. To establish a long-term conservation-management strategy for the inscription stones, the material characteristics of the inscription stones of Naksan Mountain Area were identified, and its deterioration state was diagnosed. Consequently, it was confirmed that the Inscription stones of Naksan Mountain Area mainly comprised coarse-to medium-grained pinkish granite and biotite granite, and, in part, comprised reddish granite, quartz porphyry, and aplite. Presently, the Inscription stones of Naksan Mountain Area, Hanyangdoseong, is undergoing a considerable decrease in physical properties because of physical, chemical, and biological weathering. Moreover, it has been confirmed that the type of damage, such as blistering, soiling, and dicolouration, on the surface shows a significantly high deterioration rate, and that conservation treatment might be required in future. In addition, because the possibility of damage recurrence is high even after the treatment, the conservation state must be regularly monitored.

The Long-term Operating Evaluation of the Grid Connected Photovoltaic System (태양광발전시스템의 장기운전에 의한 성능특성 분석)

  • Kim, Eui-Hwan;Kang, Seng-Won;Kim, Jae-Eon
    • New & Renewable Energy
    • /
    • v.7 no.2
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

A Study on the Repair Time of the Construction Type in the Apartment Housings (공동주택 공종별 수선시기 설정 연구)

  • Lee, Kang-Hee;Park, Geun-Soo;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.22 no.4
    • /
    • pp.83-92
    • /
    • 2011
  • Apartment is settled down as a main housing type and massive supply has been conducted since 1990's. The government has focused on the housing supply to improve the housing number and cut its price. On the contrary, the management of the housing has been neglected to get an early deterioration. Since 1995's, various ways have been made to improve and maintain the building function and performance. Among these, the long-term repair plan has played a main role to manage the housing condition and plan the repair schedule for preparing the massive cost of repair such as a roof proof, elevator change. The long-tern repair plan provides the repair time and repair rate according to various construction types. Most of the management agent apply the repair standard into the field area. But the repair time could not reflect the present condition and bring into the wrong maintenance. Therefore, the repair time for the long-term maintenance plan would be revised and reflected from the material and technology development. |n this study, it aimed at improvement for the repair time in various construction types which are provided in the long-term repair plan. For this, the 22 management agents are surveyed directly. This study shows that the repair time of the painting are correspondent to the repair time of the long-term plan irregardless of the painting materials. Most of other areas would correspondently similar to the long-term plan. This study could not include the building location, material and other haracteristics. Therefore, the further study would be needed to reflect the building and materials attributes to get the detailed repair time.

A Web-based Long-Term Repair Planning System for Apartment House (웹 기반의 공동주택 장기수선계획 시스템)

  • La Hyo-Shin;Kim Tae-Hee;Han Choong-Hee;Kim Sun-kuk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.495-500
    • /
    • 2001
  • After the completion of an apartment housing project, deterioration of building materials will commence over time. Building maintenance consists of short-time and long-term repair projects. A long-term repair plan for organized maintenance management should be developed and implemented to maintain the longevity of the building. When forming such a plan, one should carefully predict when each part of the building will need repairs and how often subsequent repairs of each part will occur. The plan should be based on these predictions. Many apartment buildings in Korea have poor long-term maintenance management plans. This is because many of these plans are developed as mere legal formalities rather than as serious attempts to maintain the longevity of buildings. In this study, the materials used in the construction of each part of an apartment building we selected are taken into account to predict when the repairs will be required and how frequently subsequent repairs will be required. Furthermore, We suggest a long-term maintenance management plan for elongation so that apartment house managers can use to periodically check, diagnose, and replace old or malfunctioning parts using a web-based maintenance calender.

  • PDF

Comparison of long-term result of Hancock and Carpentier-Edward bioprosthetic valves (Hancock과 Carpentier-Edward 이종판막의 장기 임상성적에 대한 비교 연구)

  • 김정택
    • Journal of Chest Surgery
    • /
    • v.26 no.1
    • /
    • pp.24-31
    • /
    • 1993
  • The long term clinical results following valve replacement with Hancock and Carpentier-Edwards bioprostheses were compared between tow valve models and between tow groups totaling 249 patients who were discharged after valve replacement from 1976 to 1986. The two groups of patients were treated with nonrandomized fashion. Follow-up was 87% complete. Cummulative duration of follow-up was 1909 patient-years, with maximum follow-up duration of 15 years. The actuarial survival for 122 patients with Hancock valves was 95.2%[\ulcornerstandard deviation] and 84.4% after 5 and 10 years of follow-up, respectively. Comparable figures for 127 patients undergoing valve replacement with Carpentier-Edwards valves were 87.3% and 76.4%, respectively[p=NS]. The probability of freedom from structural valve deterioration after 5 and 10 years of follow-up was 97.2% and 60.6%, respectively, with Hancock valves and 97.2% and 55.7%, respectively, with Carpentier-Edwards valves[p=NS]. Considering all 249 patients, multivariate [Cox model] regression revealed that ejection fraction was only significant predictor of structural valve deterioration. The probability of freedom from thromboembolism after 5 and 10 years of follow-up was 91.3% and 86.4%, respectively, with Hancock valves and 94.2% and 82.5%, respectively, with Carpentier-Edwards valves[p=NS]. Hence more strict control of anticoagulation should be done on patients with left atrial factors. In summary, there were no significant differences in actuarial survival rate and major valve related complications between tow valve models. These results suggests that its use should be confined to older patients or patients with a contraindication of anticoagulation.

  • PDF

Long-Term Outcome of Chronic Obstructive Pulmonary Disease: A Review

  • Jo, Yong Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.4
    • /
    • pp.289-301
    • /
    • 2022
  • Chronic obstructive pulmonary disease (COPD) is a chronic airway inflammation characterized by fixed airflow limitation and chronic respiratory symptoms, such as cough, sputum, and dyspnea. COPD is a progressive disease characterized by a decline in lung function. During the natural course of the disease, acute deterioration of symptoms leading to hospital visits can occur and influence further disease progression and subsequent exacerbation. Moreover, COPD is not only restricted to pulmonary manifestations but can present with other systemic diseases as comorbidities or systemic manifestations, including lung cancer, cardiovascular disease, pulmonary hypertension, sarcopenia, and metabolic abnormalities. These pulmonary and extrapulmonary conditions lead to the aggravation of dyspnea, physical inactivity, decreased exercise capacity, functional decline, reduced quality of life, and increased mortality. In addition, pneumonia, which is attributed to both COPD itself and an adverse effect of treatment (especially the use of inhaled and/or systemic steroids), can occur and lead to further deterioration in the prognosis of COPD. This review summarizes the long-term outcomes of patients with COPD. In addition, recent studies on the prediction of adverse outcomes are summarized in the last part of the review.

Influence of the deteriorated anti-seismic devices on seismic performance and device behavior of continuous girder bridges

  • Shangtao Hu;Renkang Hu;Menggang Yang;Dongliang Meng
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.333-343
    • /
    • 2023
  • Various seismic isolation and reduction devices have been applied to suppress the longitudinal vibration of continuous girder bridges. As representative devices, lead rubber bearing (LRB) and fluid viscous damper (FVD) might suffer from deterioration during the long-term service. This study aims to evaluate the impact of device deterioration on the seismic responses of continuous girder bridges and investigate the seismic behavior of deteriorated LRBs and FVDs. Seismic performance of a simplified bridge model was investigated, and the influence of device deterioration was evaluated by the coefficient of variation method. The contribution of LRB and FVD was assessed by the Sobol global sensitivity analysis method. Finally, the seismic behaviors of deteriorated LRBs and FVDs were discussed. The result shows that (i) the girder-pier relative displacement is the most sensitive to the changes in the deterioration level, (ii) the deterioration of FVD has a greater effect on the structural responses than that of LRB, (iii) FVD plays a major role in energy dissipation with a low degradation level while LRB is more essential in dissipating energy when suffering from high degradation level, (iv) the deteriorated devices are more likely to reach the ultimate state and thus be damaged.

Behavior of double deck tunnel due to feature change and variation of ground water table (다목적 복층터널의 기능전환과 지하수위 변화에 따른 거동분석)

  • Park, No-Hyeon;Kim, Ho-Jong;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.581-591
    • /
    • 2016
  • Several attempts to construct multi-purpose tunnel for both road and waterway have been made. The multi-purpose tunnel is mainly used as a road tunnel, however it is transferred to waterway to control flood during rainy season. The planning of the multi-purpose tunnel is recognized as cost-effective way of infrastructure construction. In case of the multi-purpose tunnel constructed beneath groundwater table, seasonal fluctuation of groundwater table and repeated flow in the tunnel may cause long-term deterioration of the tunnel system. In this study, the behavior of multi-purpose tunnel in view of groundwater table or flow in the tunnel is investigated using model test and numerical modeling method. The results have shown that rising of groundwater table caused buoyant force to the tunnel and the fluctuation of rainwater in the tunnel generated loosening of surrounding ground. It is recommended to evaluate the effect of the long-term water pressure variation in the design of a multi-purpose tunnel.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.