• Title/Summary/Keyword: Long-term deterioration

Search Result 328, Processing Time 0.023 seconds

Behavior of double lining due to long-term hydraulic deterioration of drainage system

  • Shin, Jong-Ho;Lee, In-Keun;Joo, Eun-Jung
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1257-1271
    • /
    • 2014
  • The hydraulic deterioration of the drainage system in tunnel linings is one of the main factors governing long-term lining-ground interactions during the lifetime of tunnels. Thus, in the design procedure of a tunnel below the groundwater table, the possible detrimental effects associated with the hydraulic deterioration should be addressed. Hydraulic deterioration in double-lined tunnels can occur because of reasons such as clogging of the drainage layer and drain-pipe blockings. In this study, the coupled mechanical and hydraulic interactions between linings due to drain-pipe blockings are investigated using the finite-element method. A double-lined structural model incorporating hydraulic behavior is developed to represent the coupled structural and hydraulic behavior between the linings and drainage system. It is found that hydraulic deterioration hinders flow into the tunnel, causing asymmetric development of pore-water pressure and consequent detrimental effects to the secondary lining.

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.

Evaluation of the Mechanical Properties of Field-Cast Shotcrete and Long-Term Durability by Combined Deterioration Test (현장타설 숏크리트의 역학적 성능 평가 및 복합열화시험을 통한 장기내구성 평가)

  • Ma, Sang-Joon;Jang, Phil-Sung;Kim, Dong-Min;Choi, Jae-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.47-56
    • /
    • 2007
  • Recently, tunnels are increasingly constructed in this country with the increased construction of highways, high-speed railways and subways. Shotcrete is one of the major processes in the tunnel construction. Many problems, however, exist in the current shotcrete practice. The purpose of the study is, therefore, to explore the trobles in the current shotcreting practice, and to develop high-quality silica fume shotcrete. For the purpose of security a long-term durability of shotcrete, this study conducted combined deterioration tests. In this study, a combined deterioration test in consideration of a variety of deterioration factors were proceeded. Especially, micro-silica fume that was used frequently in overseas because of a outstanding strength-promotion effect was applied to combined deterioration test, and a long-term durability of shotcrete was investigated according to additions mixing. As a result of test, the shotcrete mixed Micro-silica fume showed a good deterioration quality compared with the other mixes. And is shows that the Micro-silica fume has an outstanding strength-promotion effect and is effective to secure a long-term durability of shotcrete by means of decreasing a deterioration caused by steel fiber mixed.

Technical Aspects on Long term Reliability of Porcelain Insulators for Transmission Line (송전용 애자의 과전 열화 신뢰성 평가 기술)

  • Han, S.W.;Cho, H.G.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.255-257
    • /
    • 2003
  • The reliability of power transmission lines depends on long-term performance of the suspension insulators used on the lines. The importance of such long-term performance of the insulators has been recently noted, but its evaluation method has not been established yet. In this paper, various causes of insulator deterioration are verified and laboratory test method for evaluating the long term performance of insulators are studied.

  • PDF

Internal Property and Stochastic Deterioration Modeling of Total Pavement Condition Index for Transportation Asset Management (도로자산관리를 위한 포장종합평가지수의 속성과 변화과정의 모델링)

  • HAN, Daeseok;DO, Myungsik;KIM, Booil
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.1-11
    • /
    • 2017
  • PURPOSES : This study is aimed at development of a stochastic pavement deterioration forecasting model using National Highway Pavement Condition Index (NHPCI) to support infrastructure asset management. Using this model, the deterioration process regarding life expectancy, deterioration speed change, and reliability were estimated. METHODS : Eight years of Long-Term Pavement Performance (LTPP) data fused with traffic loads (Equivalent Single Axle Loads; ESAL) and structural capacity (Structural Number of Pavement; SNP) were used for the deterioration modeling. As an ideal stochastic model for asset management, Bayesian Markov multi-state exponential hazard model was introduced. RESULTS:The interval of NHPCI was empirically distributed from 8 to 2, and the estimation functions of individual condition indices (crack, rutting, and IRI) in conjunction with the NHPCI index were suggested. The derived deterioration curve shows that life expectancies for the preventive maintenance level was 8.34 years. The general life expectancy was 12.77 years and located in the statistical interval of 11.10-15.58 years at a 95.5% reliability level. CONCLUSIONS : This study originates and contributes to suggesting a simple way to develop a pavement deterioration model using the total condition index that considers road user satisfaction. A definition for level of service system and the corresponding life expectancies are useful for building long-term maintenance plan, especially in Life Cycle Cost Analysis (LCCA) work.

Numerical modeling of coupled structural and hydraulic interactions in tunnel linings

  • Shin, J.H.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.1
    • /
    • pp.1-16
    • /
    • 2008
  • Tunnels are generally constructed below the ground water table, which produces a long-term interaction between the tunnel lining and the surrounding geo-materials. Thus, in conjunction with tunnel design, the presence of water may require a number of considerations such as: leakage and water load. It has been reported that deterioration of a drainage system of tunnels is one of the main factors governing the long-term hydraulic and structural lining-ground interaction. Therefore, the design procedure of an underwater tunnel should address any detrimental effects associated with this interaction. In this paper an attempt to identify the coupled structural and hydraulic interaction between the lining and the ground was made using a numerical method. A main concern was given to local hindrance of flow into tunnels. Six cases of local deterioration of a drainage system were considered to investigate the effects of deterioration on tunnels. It is revealed that hindrance of flow increased pore-water pressure on the deteriorated areas, and caused detrimental effects on the lining structures. The analysis results were compared with those from fully permeable and impermeable linings.

Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System (알루미나계 자기애자의 장기 피로특성에 관한 연구)

  • Han, Se-Won;Cho, Han-Goo;Lee, Dong-Il;Cho, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

Long-Term Preservation Measures of Paper Records of Special Preserving Organization (특수 보존 기관의 종이 기록물 장기 보존 대책)

  • Shin, Jong-Soon;Lee, Jae-Soo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2012
  • This study is Long term preservation measures which is closely related to preserving paper records, record condition evaluation, preservation measure and is conducted as follows. As for Means to Evaluate the Deterioration and Damaged Conditions of Records, research and analysis has been made on the contamination and deterioration examples such as damage, dry, stapler, metal, contamination, acidification which are the characteristics of paper record damage types. The of Paper record is one of the key procedures to evaluate the record material and its physi-chemical status in many criteria and to suggest the best preservation method. Between 1970 and 2000, the main record materials was fine paper and OMR paper along with partly newspaper and coarse paper, whereas the main recording material was ball point pen. Overall damage and deterioration status is, for record materials between 1940 and 1960, high deterioration was found and in urgent need for preservation measure and more damages are caused by tapes, staplers and metals. As for records after 1970, there is light deterioration but needs preservation process. There are approximately 3 million records produces before 2000, and assuming that there are 30 pages per record and that 30% has been damaged or deteriorated, 27 million pages are subject to preservation process. Among damaged or deteriorated records, there are large number of records impossible to go through deacidification process so manual preservation and restoration process is necessary as well. Securing manpower having preservation and restoration skills as well as preservation equipment(deacidification process, preservation and restoration) is in urgent need.

Durability Evaluation of Grout in Cablebolt System (케이블볼트 충전재의 내구성 평가)

  • Choi, Jung-In;Kim, Won-Keun;Jeon, Jae-Hyun;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.553-561
    • /
    • 2010
  • Like the shotcrete can be deteriorated by chemical compounds as service years increase, the grout which is used to fasten the cablebolt(rockbolt) system in the underground structures also can be deteriorated by chemical compounds such as sulphate and/or chloride contained in groundwater during service years. This can induce issues on the long term durability of cablebolt(rockbolt) system and consequently on the stability of underground structures. In this study, the deteriorations of long term durability of cement mortar grout by each chemical compound of sulphate or chloride are studied experimentally and also complex deterioration by the mix of sulphate and chloride is investigated. Based on the results obtained in this study, the characteristics and prediction of deterioration of long term durability of cement mortar grout for cablebolt(rockbolt) system are suggested.

  • PDF

The Study on Long-Term Monitoring System of Bridge (교량의 상시감시 시스템 구축에 관한 연구)

  • 박승범;조광연;홍석주;최상필
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.813-818
    • /
    • 1999
  • The construction of large scale civil and building structures which form the base of social economy has been grown greatly. As the increasing of aged and deteriorated structures, it is necessary to evaluate the safety of those structures. The deterioration, safety evaluation, repair and rehabilitation are important problems in the construction area that every country faces. This paper presents the general information on how to conduct a data analysis of long-term monitoring system and evaluate the characteristics of surveying methods.

  • PDF