• 제목/요약/키워드: Long-term deterioration

검색결과 328건 처리시간 0.027초

Behavior of double lining due to long-term hydraulic deterioration of drainage system

  • Shin, Jong-Ho;Lee, In-Keun;Joo, Eun-Jung
    • Structural Engineering and Mechanics
    • /
    • 제52권6호
    • /
    • pp.1257-1271
    • /
    • 2014
  • The hydraulic deterioration of the drainage system in tunnel linings is one of the main factors governing long-term lining-ground interactions during the lifetime of tunnels. Thus, in the design procedure of a tunnel below the groundwater table, the possible detrimental effects associated with the hydraulic deterioration should be addressed. Hydraulic deterioration in double-lined tunnels can occur because of reasons such as clogging of the drainage layer and drain-pipe blockings. In this study, the coupled mechanical and hydraulic interactions between linings due to drain-pipe blockings are investigated using the finite-element method. A double-lined structural model incorporating hydraulic behavior is developed to represent the coupled structural and hydraulic behavior between the linings and drainage system. It is found that hydraulic deterioration hinders flow into the tunnel, causing asymmetric development of pore-water pressure and consequent detrimental effects to the secondary lining.

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • 보존과학회지
    • /
    • 제38권4호
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.

현장타설 숏크리트의 역학적 성능 평가 및 복합열화시험을 통한 장기내구성 평가 (Evaluation of the Mechanical Properties of Field-Cast Shotcrete and Long-Term Durability by Combined Deterioration Test)

  • 마상준;장필성;김동민;최재석
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.47-56
    • /
    • 2007
  • 최근들어 고속도로, 고속철도, 지하철등의 건설이 증가하면서 터널의 건설도 늘어나고 있는 추세이다. 이러한 터널 공사에서 필수적으로 따르는 것이 숏크리트 공정이며 이러한 숏크리트의 시공은 앞으로도 더욱 증가할 추세에 있다. 그러나 숏크리트의 광범위한 시공에도 불구하고 여러 가지 문제점을 내포하고 있는 것이 사실이다. 따라서 본 연구에서는 우리나라 현행 숏크리트의 현황과 문제점을 분석하고, 고품질의 숏크리트 시공을 위하여 실리카퓸 숏크리트의 성능 및 적용성에 대해 분석하였다. 또한 숏크리트의 장기적인 안정성 확보를 위해서는 복합적인 환경조건을 고려한 열화 특성을 파악할 필요가 있다. 본 연구에서는 건습 반복, 동결융해 및 탄산화 등의 열화 인자를 복합적으로 적용한 열화 시험을 수행하였다. 특히, 우수한 강도 증진 효과로 국외에서 많이 사용되고 있는 실리카퓸을 적용하여 혼화재 치환에 따른 숏크리트의 장기 내구 특성을 평가하였다. 복합 열화 시험 결과 실리카퓸을 혼입한 숏크리트는 다른 배합에 비해 가장 양호한 결과를 나타냈고, 실리카퓸은 강도 증진 효과와 함께 강섬유 혼입에 의한 열화 현상을 최소한으로 감소시켜 숏크리트의 장기 내구성을 확보하는데 효과가 있었다.

송전용 애자의 과전 열화 신뢰성 평가 기술 (Technical Aspects on Long term Reliability of Porcelain Insulators for Transmission Line)

  • 한세원;조한구;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.255-257
    • /
    • 2003
  • The reliability of power transmission lines depends on long-term performance of the suspension insulators used on the lines. The importance of such long-term performance of the insulators has been recently noted, but its evaluation method has not been established yet. In this paper, various causes of insulator deterioration are verified and laboratory test method for evaluating the long term performance of insulators are studied.

  • PDF

도로자산관리를 위한 포장종합평가지수의 속성과 변화과정의 모델링 (Internal Property and Stochastic Deterioration Modeling of Total Pavement Condition Index for Transportation Asset Management)

  • 한대석;도명식;김부일
    • 한국도로학회논문집
    • /
    • 제19권5호
    • /
    • pp.1-11
    • /
    • 2017
  • PURPOSES : This study is aimed at development of a stochastic pavement deterioration forecasting model using National Highway Pavement Condition Index (NHPCI) to support infrastructure asset management. Using this model, the deterioration process regarding life expectancy, deterioration speed change, and reliability were estimated. METHODS : Eight years of Long-Term Pavement Performance (LTPP) data fused with traffic loads (Equivalent Single Axle Loads; ESAL) and structural capacity (Structural Number of Pavement; SNP) were used for the deterioration modeling. As an ideal stochastic model for asset management, Bayesian Markov multi-state exponential hazard model was introduced. RESULTS:The interval of NHPCI was empirically distributed from 8 to 2, and the estimation functions of individual condition indices (crack, rutting, and IRI) in conjunction with the NHPCI index were suggested. The derived deterioration curve shows that life expectancies for the preventive maintenance level was 8.34 years. The general life expectancy was 12.77 years and located in the statistical interval of 11.10-15.58 years at a 95.5% reliability level. CONCLUSIONS : This study originates and contributes to suggesting a simple way to develop a pavement deterioration model using the total condition index that considers road user satisfaction. A definition for level of service system and the corresponding life expectancies are useful for building long-term maintenance plan, especially in Life Cycle Cost Analysis (LCCA) work.

Numerical modeling of coupled structural and hydraulic interactions in tunnel linings

  • Shin, J.H.
    • Structural Engineering and Mechanics
    • /
    • 제29권1호
    • /
    • pp.1-16
    • /
    • 2008
  • Tunnels are generally constructed below the ground water table, which produces a long-term interaction between the tunnel lining and the surrounding geo-materials. Thus, in conjunction with tunnel design, the presence of water may require a number of considerations such as: leakage and water load. It has been reported that deterioration of a drainage system of tunnels is one of the main factors governing the long-term hydraulic and structural lining-ground interaction. Therefore, the design procedure of an underwater tunnel should address any detrimental effects associated with this interaction. In this paper an attempt to identify the coupled structural and hydraulic interaction between the lining and the ground was made using a numerical method. A main concern was given to local hindrance of flow into tunnels. Six cases of local deterioration of a drainage system were considered to investigate the effects of deterioration on tunnels. It is revealed that hindrance of flow increased pore-water pressure on the deteriorated areas, and caused detrimental effects on the lining structures. The analysis results were compared with those from fully permeable and impermeable linings.

알루미나계 자기애자의 장기 피로특성에 관한 연구 (Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System)

  • 한세원;조한구;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

특수 보존 기관의 종이 기록물 장기 보존 대책 (Long-Term Preservation Measures of Paper Records of Special Preserving Organization)

  • 신종순;이재수
    • 한국인쇄학회지
    • /
    • 제30권1호
    • /
    • pp.59-69
    • /
    • 2012
  • This study is Long term preservation measures which is closely related to preserving paper records, record condition evaluation, preservation measure and is conducted as follows. As for Means to Evaluate the Deterioration and Damaged Conditions of Records, research and analysis has been made on the contamination and deterioration examples such as damage, dry, stapler, metal, contamination, acidification which are the characteristics of paper record damage types. The of Paper record is one of the key procedures to evaluate the record material and its physi-chemical status in many criteria and to suggest the best preservation method. Between 1970 and 2000, the main record materials was fine paper and OMR paper along with partly newspaper and coarse paper, whereas the main recording material was ball point pen. Overall damage and deterioration status is, for record materials between 1940 and 1960, high deterioration was found and in urgent need for preservation measure and more damages are caused by tapes, staplers and metals. As for records after 1970, there is light deterioration but needs preservation process. There are approximately 3 million records produces before 2000, and assuming that there are 30 pages per record and that 30% has been damaged or deteriorated, 27 million pages are subject to preservation process. Among damaged or deteriorated records, there are large number of records impossible to go through deacidification process so manual preservation and restoration process is necessary as well. Securing manpower having preservation and restoration skills as well as preservation equipment(deacidification process, preservation and restoration) is in urgent need.

케이블볼트 충전재의 내구성 평가 (Durability Evaluation of Grout in Cablebolt System)

  • 최정인;김원근;전재현;이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.553-561
    • /
    • 2010
  • Like the shotcrete can be deteriorated by chemical compounds as service years increase, the grout which is used to fasten the cablebolt(rockbolt) system in the underground structures also can be deteriorated by chemical compounds such as sulphate and/or chloride contained in groundwater during service years. This can induce issues on the long term durability of cablebolt(rockbolt) system and consequently on the stability of underground structures. In this study, the deteriorations of long term durability of cement mortar grout by each chemical compound of sulphate or chloride are studied experimentally and also complex deterioration by the mix of sulphate and chloride is investigated. Based on the results obtained in this study, the characteristics and prediction of deterioration of long term durability of cement mortar grout for cablebolt(rockbolt) system are suggested.

  • PDF

교량의 상시감시 시스템 구축에 관한 연구 (The Study on Long-Term Monitoring System of Bridge)

  • 박승범;조광연;홍석주;최상필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.813-818
    • /
    • 1999
  • The construction of large scale civil and building structures which form the base of social economy has been grown greatly. As the increasing of aged and deteriorated structures, it is necessary to evaluate the safety of those structures. The deterioration, safety evaluation, repair and rehabilitation are important problems in the construction area that every country faces. This paper presents the general information on how to conduct a data analysis of long-term monitoring system and evaluate the characteristics of surveying methods.

  • PDF