• 제목/요약/키워드: Long-period Ground Motions

검색결과 45건 처리시간 0.018초

Diurnal Variation of Atomospheric Pollutant Concentrations Affected by Development of Windstorms along the Lee Side of Coastal Mountain Area

  • Choi, Hyo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제24권1호
    • /
    • pp.29-45
    • /
    • 1996
  • Before (March 26, 1994) or after the occurrence of a downslope windstorm (March 29), the NO, $NO_2$, and $SO_2$ at the ground level of Kangnung city were monitored with high concentrations in the afternoon, due to a large amount of gases emitted from combustion of motor vehicle and heating apparatus, especially near 1600-1800 LST and 2000-2100 LST, but at night, they had low concentrations, resulting from small consumptions of vehicle and heating fuels. When both moderate westerly synoptic-scale winds flow over Mt. Taegwallyang and easterly meso-scale sea breeze during the day, atmospheric pollutants should be trapped by two different wind systems, resulting in higher concentration at Kangnung city in the afternoon. At night, the association of westerly synoptic wind and land breeze can produce relatively strong winds and the dissipation by the winds cause these low concentrations to lower and lower, as nightime goes on. From March 27 through 28, an enforced localized windstorm could be produced along the lee side of the mountain near Kangnung, generating westerly internal gravity waves with hydraulic jump motions. Sea breeze toward inland appartantly confines to the bottom of the eastern side of the mountain, due to the interruption of eastward violent internal gravity waves. As the windstorm moves down toward the ground, an encountering point of two opposite winds approaches Kangnung, and a great amount of NO and $NO_2$ were removed by the strong surface winds. Thus, their maximum concentrations are found to be near 18 and 20 LST, 17 and 21 LST. In the nighttime, the more developed storm should produce very strong surface winds and the NO and $NO_2$ could be easily dissipated into other place. The $SO_2$ concentration had no maximum value, that is, almost constant one all day long, due to its removal by the strong surface winds. Especially, the CO concentrations were slightly lower during the strom period than both before or after the strom, but they were nearly constant without much changes during the during the daytime and nighttime.

  • PDF

근단층지반운동에 대한 상부구조 질량 변화에 따른 RC 교각의 응답분석 (Response Analysis of RC Bridge Pier with Various Superstructure Mass under Near-Fault Ground Motion)

  • 박창규;정영수;이대형
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.667-673
    • /
    • 2010
  • 근단층지반운동은 진앙거리가 약 10 km 이내인 지역에서 관측되는 장주기 성분의 펄스형태를 갖는 지반운동으로서, 도심지에서 발생할 경우 미국 Northridge(1994), 일본 Kobe(1995), 터키 Izmit(1999), 중국 쓰촨성(2008), 아이티지진(2010) 등과 같이 매우 큰 피해를 야기시킨다. 이에 강진지역에서는 NFGM에 대한 많은 연구가 수행되었으나 우리나라와 같은 중약진 지역에서는 매우 미흡한 실정이다. 이 연구에서는 근단층 지반운동을 받는 철근콘크리트 교각의 거동과 내진성능을 평가하기 위하여 6기의 실험체에 대하여 진동대 실험을 수행하였다. 주요 실험 변수로는 심부구속철근비와 상부질량 크기로서 진동대 실험 결과 심부구속철근비가 적거나 상부질량이 클수록 교각의 내진성능이 저하됨을 알 수 있었다. 또한 진동대 실험 결과를 분석하여 지진동을 받는 교각의 강성변화에 대한 심부구속철근비와 질량의 영향을 분석하였으며, 변위연성도와 강성과의 관계식을 제안하였다.

유산소 운동능력 향상을 위한 중량물 부가 신발의 기능성 평가 (The Evaluation of an additional Weight Shoe's Function developed for the Improvement of Aerobic Capacity)

  • 곽창수;김희석
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.67-82
    • /
    • 2004
  • The purpose of this study was to evaluate the function and the safety of an additional weight shoe developed for the improvement of aerobic capacity, and to improve some problems found by subject's test for an additional weight shoe. The subjects employed for this study were 10 college students. 4 video cameras, AMTI force platform and Pedar insole pressure distribution measurement device were used to analyze foot motions. The results of the study were as follows: 1 The initial achilles tendon angle and initial rearfoot pronation angle of an additional weight shoe during walking were 183.7 deg and 2.33 deg, respectively, and smaller than a barefoot condition. Maximum achilles tendon angle and the angular displacement of achilles tendon angle were 185.35 deg and 4.21 deg respectively, and smaller than barefoot condition. Thus rearfoot stability variables were within the permission value for safety. 2. Maximal anterior posterior ground reaction force of additional weight shoe was appeared to be 1.01-1.2 B.W., and was bigger than a barefoot condition. The time to MAPGRF of an additional weight shoe was longer than a barefoot condition. Maximal vertical ground reaction force of additional weight shoe was appeared to be 2.3-2.7 B.W., and was bigger than a barefoot condition in propulsive force region. But A barefoot condition was bigger in braking force region. The time to MVGRF of an additional weight shoe was longer than a barefoot condition. 3. Regional peak pressure was bigger in medial region than in lateral region in contrast to conventional running shoes. The instant of regional peak pressure was M1-M2-M7-M4-M6-M5 -M3, and differed form conventional running shoes. Regional Impulse was shown to be abnormal patterns. There were no evidences that an additional weight shoe would have function and safety problems through the analysis of rearfoot control and ground reaction force during walking. However, There appeared to have small problem in pressure distribution. It was considered that it would be possible to redesign the inner geometry. This study could not find out safety on human body and exercise effects because of short term research period. Therefore long term study on subject's test would be necessary in the future study.

Kern County 지진에 대한 연구 (A study of Kem County earthquake)

  • 김준경
    • 지질공학
    • /
    • 제2권2호
    • /
    • pp.155-165
    • /
    • 1992
  • 본 연구는 한반도의 지진지체구조 특성에 부합되는 내진설계용 부지응답 스펙트럼 작성을 위한 유사지진 선정에 관한 연구이다. Seismic Moment Tensor를 이용 파형을 Inversion한 결과에 의하면 지진원 특성상, Kern Conty 지진(1952년 7월 21일, 리히터 규모 ML = 7.2)은 한반도 지진지체구조 특성에 부합되는 현실적으로 유사한 외국의 지진들 중의 하나로서, 선정된 Kern Conty 지진으로 부터 발생한 강지진동 자료를 전산처리하여 표준응답 스펙트럼과 일반적 특성을 비교하여 보는 일도 의미있는 일이라고 할 수 있다.

  • PDF

테프론 또는 제강슬래그를 활용한 기초형 지진격리장치의 면진 메카니즘 평가 (Evaluation of Isolation Mechanism of Teflon or Steel Slag-Type Seismic Foundation Isolation Systems)

  • 손수원;강인구;푸얀 벅게리;김진만
    • 한국지반공학회논문집
    • /
    • 제34권1호
    • /
    • pp.5-16
    • /
    • 2018
  • 본 연구에서는 지반에서 1차적인 면진작용을 할 수 있는 지반형 지진격리장치의 내진성능을 평가하였다. 테프론과 제강슬래그를 이용하여 지반형 지진격리장치를 조성한 후 그 위에 모형 상부구조물을 설치하고 1-G 진동대 실험을 수행하였다. 다양한 수준의 입력지진파에 대해 응답가속도와 응답스펙트럼을 분석하였으며, 지진격리장치가 없는 고정기초 구조물과 결과를 비교하였다. 연구결과, 제강슬래그형 지진격리장치가 가장 가속도 저감효과가 좋았으며, 테프론형 지진격리장치는, 중 약진 조건에서는 가속도 저감효과가 크게 없고 강진조건에서는 가속도 저감효과가 좋았다. 입력파가 상부질량(Mass)으로 전달되면서, 고정기초 구조물의 응답스펙트럼은 입력지진파에 비해 단주기영역에서 증폭하고, 테프론과 제강슬래그를 이용한 지진격리장치가 있는 구조물의 응답스펙트럼은 입력지진파에 비해 장주기 영역에서 증폭하였다. 이러한 주기특성 변화와 재료간의 마찰특성이 가속도 저감효과에 영향을 준 것으로 판단된다.