• Title/Summary/Keyword: Long-line method

Search Result 508, Processing Time 0.026 seconds

Characteristics of periodical movement of live squid (Todarodes pacificus) hooked on the branch line of a red sea bream long line

  • Koo, Myung Sung;Ishizaki, Munechika;Kim, Suk Jong;Fuwa, Shigeru;Archdale, Miguel Vazquez
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.227-237
    • /
    • 2013
  • In Jeju Island, red sea bream is mainly caught by long line with a live squid as bait. The movements of artificial jigs in the fishery are supposed to be an important factor for catching the target organism as well as bait. To develop new fishing method for long line fishery, movements of the bait which was squid were tried to be characterized. In a water tank experiment, a live squid was hooked by a fish hook attached to a model long line. And then movements of squids in the water tank were recorded for 20 minutes by a video camera. Recorded movement of the squid was just periodically up-and-down moving, with a dominant frequency of 0.125Hz, and amplitude of 10.8cm.

Forced reclosing in transmission line (송전선의 강제재폐로)

  • 김준현
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.401-409
    • /
    • 1980
  • This paper deals with the implementation of forced reclosing the transmission line. Because the ground circuit breaker method decrease the secondary arc current sufficiently, the reclosing time can be reduced. As the secondary arc current is large and its residual time is long in UHV transmission line, this method is more effective in that system. The resistance of ground circuit breaker which minimize the secondary arc current is determined according to the system voltage and the length of transmission line.

  • PDF

A Reform Measure of the Structure and Transaction Process for the Safety Improvement of a Credit Card (신용카드의 안전성 향상을 위한 구조 및 거래절차 개선방법)

  • Lee, Young Gyo;Ahn, Jeong Hee
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.3
    • /
    • pp.63-74
    • /
    • 2011
  • Credit cards are more convenient than cash of heavy. Therefore, credit cards are used widely in on_line (internet) and off_line in nowadays. To use credit cards on internet is commonly secure because client identification based security card and authentication certificate. However, to use in off_line as like shop, store, department, restaurant is unsecure because of irregular accident. As client identification is not used in off_line use of credit cards, the irregular use of counterfeit, stolen and lost card have been increasing in number recently. Therefore, client identification is urgently necessary for secure card using in off_line. And the method of client identification must be simple, don't take long time, convenient for client, card affiliate and card company. In this paper, we study a reform measure of the structure and transaction process for the safety improvement of a credit cards. And we propose several authentication method of short-and long-term for client identification. In the proposal, the client authentication method by OTP application of smart-phone is efficient nowadays.

Technical Aspects on Long term Reliability of Porcelain Insulators for Transmission Line (송전용 애자의 과전 열화 신뢰성 평가 기술)

  • Han, S.W.;Cho, H.G.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.255-257
    • /
    • 2003
  • The reliability of power transmission lines depends on long-term performance of the suspension insulators used on the lines. The importance of such long-term performance of the insulators has been recently noted, but its evaluation method has not been established yet. In this paper, various causes of insulator deterioration are verified and laboratory test method for evaluating the long term performance of insulators are studied.

  • PDF

Vortex induced vibration and its controlling of long span Cross-Rope Suspension transmission line with tension insulator

  • Tu, Xi;Wu, Ye;Li, Zhengliang;Wang, Zhisong
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.87-102
    • /
    • 2021
  • Long span cross-rope suspension structure is an innovative structural system evolved from typical Cross-Rope Suspension (CRS) guyed tower, a type of supporting system with short span suspension cable supporting overhead power transmission lines. In mountainous areas, the span length of suspension cable was designed to be extended to hundreds or over one thousand meters, which is applicable for crossing deep valleys. Vortex Induced Vibration (VIV) of overhead power transmission lines was considered to be one of the major factors of its fatigue and service life. In this paper, VIV and its controlling by Stockbridge damper for long span CRS was discussed. Firstly, energy balance method and finite element method for assessing VIV of CRS were presented. An approach of establishing FE model of long span CRS structure with dampers was introduced. The effect of Stockbridge damper for overall vibration of CRS was compared in both theoretical and numerical approaches. Results indicated that vibration characteristics of conductor in long span CRS compared with traditional tower-line system. Secondly, analysis on long span CRS including Stockbridge damper showed additional dampers installed were essential for controlling maximum dynamic bending stresses of conductors at both ends. Moreover, factors, including configuration and mass of Stockbridge damper, span length of suspension cable and conductor and number of spans of conductor, were assessed for further discussion on VIV controlling of long span CRS.

A Novel data line sharing method for high pixel density LCoS microdisplays

  • Song, Yu-Long;Ling, Zhihua
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-51
    • /
    • 2006
  • A new data line reduction driving method was developed for high pixel density LCoS microdisplays. Its pixel structures and its corresponding gate line waveform were proposed, too. This idea can fulfill the increasing demand for higher resolution LCoS. In this method, no additional AC power is dissipated, and no more horizontal line time is needed. So this method can be applied to the high resolution microdisplay devices. It prefers being applied to the reflective liquid crystal on silicon microdisplays because of the pixel structure asymmetry and PMOS transistor switches used.

  • PDF

Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current (대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF

The Body Measuring Method to Classify Sasang Constitutions (체간 측정법에 의한 체질판별)

  • Koh, Byung-Hee;Song, Il-Byung;Huh, Mahn-Hoi
    • Journal of Sasang Constitutional Medicine
    • /
    • v.14 no.1
    • /
    • pp.51-66
    • /
    • 2002
  • The main purpose of this study is to differentiate Sasang Constitutions of men and women by measuring 5 parts of the body. By the definitions about Four Chos(四焦) in ${\ulcorner}$The Discourse on Viscera and Bowels(臟腑論)${\lrcorner}$, the body is divided into four parts and sets up the five borderlines. They are Top-line, Bosom-line, Stomach-line, Navel-line and Bottom-line. Top-line(第一線) is the horizontal distance between Rt. & Lt. Coracoid processes passing through the acupuncture point CV-22(天突穴) or the horizontal distance between Rt. & Lt. beginning points of Axillary lines. Bosom-line(第二線) is the horizontal distance passing through Rt.& Lt. Nipples. Stomach-line(第三線) is the horizontal distance passing through Rt.& Lt. acupuncture point ST-19(不容穴). Navel-line(第四線) is the horizontal distance passing through the navel(CV-8; 神闕穴) and the acupuncture point ST-25(天樞穴). Bottom-line(第五線) is the horizontal distance between Rt. & Lt. Anterior Superior Iliac Spine(ASIS). The measured numerical values of Five Lines are the most important factors to classify the Four Constitutions(Taeyangin, Taeumin, Soyangin, Soeumin). Among the five lines, Stomach-line(Middle-line) is the base line to decide Yin and Yang. As a result, I could differentiate the four Constitutions as follows. 1. Taeyangin's Top-line is more than 36cm long. Top-line is the longest. Bottom-line is the shortest. The length-difference between Top-line and Bottom-line is more or less 10cm long. 2. In case of Taeumin, Navel-line is the longest. The numerical values of Middle and Bottom lines are almost the same or Bottom-line is shorter than Middle-line by 1 or 2 cm long. In some special case, the five lines are all the same and the body just looks like a log. 3. In case of Soyangin, just like Taeyangin, Top-line is the longest. Bottom-line is the shortest. The length of Top-line is ranged between 30cm to 35cm long. From Top-line to Bottom-line, the length gradually diminishes each by 2cm: for example, 34-32-30-28-26. 4. In case of Soeumin, the longest one is Bottom-line. Specially, Navel-line is shorter than Middle-line. Bottom-line is longer than the Middle.

  • PDF

A Study on the Corset Type Long-Line Brassieres Pattern Development for Adult Women : focusing on women in their 20s (성인 여성용 코르셋형 롱라인브래지어 패턴개발 - 20대 여성을 대상으로 -)

  • Sohn, Hoo Jo;Na, Mi-Hyang
    • Fashion & Textile Research Journal
    • /
    • v.14 no.6
    • /
    • pp.960-967
    • /
    • 2012
  • The study aims to design the corset type long-line bra patterns that compensate part-somatotype of women in their 20s. The corset type long-line research bra patterns consist of 4 sections: cup, front bodice, back bodice, and shoulder strap. The full cup is made up of 2 lower part pieces and 1 upper part piece, and the shoulder strap is 16 millimeters wide. The method to design the patterns is shown in figure 4 and figure 5. The result of wearing test showed that, while the wearing testers recognized some significant differences in 19 out of 26 criteria, the examiners did in 17 out of 23. The criteria more than 1 in an average value between research bras and commercial bras were 'appropriateness of breadth of shoulder strap', 'appropriateness of pressure of armhole circumference'. 'appropriateness of pressure of waist', 'suitability of side line and body curve', 'appropriateness of positional pressure of chest circumference', 'appropriateness of positional pressure of upper part line', 'appropriateness of positional pressure of bottom part line', and 'satisfaction of whole silhouette of side and back'. The research and commercial bras were evaluated 4.23 and 3.44 respectively by the testers, and 4.25 and 3.40 by the examiners. The former ones were scored higher by both parties. They were also appreciated higher in general silhouettes of fitting and appearance.

A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line (장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.