• Title/Summary/Keyword: Long-distance sensor

Search Result 155, Processing Time 0.032 seconds

Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition (점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향)

  • 김철수;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.2
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

An Implementation of UWB IR System for Long Distance and High-precision Localization (장거리 고정밀 측위를 위한 UWB IR 시스템 구현)

  • Kim, Ki-Yun;Kim, Gil-Gyeom;Kim, Tae-Kwon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.87-95
    • /
    • 2016
  • Recently, the interests of the precise localization are rapidly increasing, which are linked to IoT(Internet of Things) sensors. The precise localization in indoor environment can be utilized in navigation, security, anti-collision, and various location based services etc. However, conventional positioning sensors, such as PIR, ultrasonic, microwave etc. are vulnerable to weather or insensitive to direction of subject movement or low precision performance. In this paper we implement a UWB-IR localization system for long distance and high-precision localization, which is not affected by temperature, light and weather. The proposed system was divided and designed by H/W, Antenna, S/W parts, each of which was designed based on an accurate analysis and simulation. As a result, we can implemented and verified UWB IR system with precise localization performance.

Performance Analysis of Scanning Scheme Using ToF for the Localization of Optics-Based Sensor Node (광신호 기반 무선 센서 노드 위치 인식을 위한 ToF 기법의 성능 분석)

  • Jang, Woo Hyeop;Park, Chan Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.268-274
    • /
    • 2013
  • In this paper, the performance analysis of optics-based sensor node localization using ToF (Time of Flight) scheme is conducted. Generally, the position of the sensor node is calculated on the base station. And the base station scans neighboring sensor nodes with a laser. The laser which is reflected from one sensor node, however, can be reached to the base station at different angles according to the scanning resolution. This means that the error of the reached angle can increase and one node may be recognized as different nodes. Also the power of laser can decrease because the laser signal spread. Thus the sensor node which is located at a long distance from the base station cannot be detected. In order to overcome these problems which can be occurred in localization using ToF, the beam spot, the scanning resolution, the size of reflector and the power of laser at the sensor node were analyzed. It can be expected that the consequence of analysis can be provided in acquisition of accurate position of sensor node and construction of optics-based sensor node localization system.

A Study on 2-Dimensional Sound Source Tracking System IV - Mainly on Approximation of the Relative Bearing and Distance - (2차원적 음원추적에 관한 연구IV -음원위치의 근사적 결정법을 중심으로 -)

  • 문성배;전승환
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.4
    • /
    • pp.371-379
    • /
    • 2001
  • We have reported the new measurement system which was substituted digital filter for the analog filter in order to develop the optimal system that could find the time delay between each sensors with high accuracy. And also we have confirmed through the experiments that the accuracy of measurements were differentiated by the methods what kind of digital filter had been adopted. This paper suggests two algorithms which approximate the sound source's bearing and distance. One is that sound source's relative bearing can be approximately regarded as the gradient of hyperbolic asymptote, the other is that the source's range can be approximated under the condition of a long range source relative to the sensor's interval. And a series of experiments were carried out with the source's distance 22.42meters and the random bearing interval within the limits of $-90^{\circ}$~$+90^{\circ}$. As a result, we have recognized that the approximation methods could measure the bearing and distance with higher accuracy than the method using trigonometric relation could do.

  • PDF

Sensor Route Management Scheme for Wireless Sensor Network

  • Rahman, Md. Obaidur;Hong, Choong-Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.1283-1285
    • /
    • 2007
  • A wireless sensor network is the combination of a large number of deployed sensors over an area. Communication between the sensors is the most important factor for a successful sensor network. It is mandatory that long distance and multi-hop communication will occur between sensors. Generally sensors relay the sensed data of a particular territory to the command center via a base station. For the non uniformed deployment of sensors many sensors may deploy in hostile areas surrounded by full of obstacles or in other condition it may be out of the direct communication range of the base station. It seems a critical problem for routing data to and from those sensors to the base station. This paper proposes a route management scheme using a dynamic load balancing approach based on residual energy of each agent sensors.

  • PDF

A Self-Powered RFID Sensor Tag for Long-Term Temperature Monitoring in Substation

  • Chen, Zhongbin;Deng, Fangming;He, Yigang;Liang, Zhen;Fu, Zhihui;Zhang, Chaolong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.501-512
    • /
    • 2018
  • Radio frequency identification (RFID) sensor tag provides several advantages including battery-less operation and low cost, which are suitable for long-term monitoring. This paper presents a self-powered RFID temperature sensor tag for online temperature monitoring in substation. The proposed sensor tag is used to measure and process the temperature of high voltage equipments in substation, and then wireless deliver the data. The proposed temperature sensor employs a novel phased-locked loop (PLL)-based architecture and can convert the temperature sensor in frequency domain without a reference clock, which can significantly improve the temperature accuracy. A two-stage rectifier adopts a series of auxiliary floating rectifier to boost its gate voltage for higher power conversion efficiency. The sensor tag chip was fabricated in TSMC $0.18{\mu}m$ 1P6M CMOS process. The measurement results show that the proposed temperature sensor tag achieve a resolution of $0.15^{\circ}C$/LSB and a temperature error of $-0.6/0.7^{\circ}C$ within the range from $-30^{\circ}C$ to $70^{\circ}C$. The proposed sensor tag achieves maximum communication distance of 11.8 m.

Optimal sensor placement under uncertainties using a nondirective movement glowworm swarm optimization algorithm

  • Zhou, Guang-Dong;Yi, Ting-Hua;Zhang, Huan;Li, Hong-Nan
    • Smart Structures and Systems
    • /
    • v.16 no.2
    • /
    • pp.243-262
    • /
    • 2015
  • Optimal sensor placement (OSP) is a critical issue in construction and implementation of a sophisticated structural health monitoring (SHM) system. The uncertainties in the identified structural parameters based on the measured data may dramatically reduce the reliability of the condition evaluation results. In this paper, the information entropy, which provides an uncertainty metric for the identified structural parameters, is adopted as the performance measure for a sensor configuration, and the OSP problem is formulated as the multi-objective optimization problem of extracting the Pareto optimal sensor configurations that simultaneously minimize the appropriately defined information entropy indices. The nondirective movement glowworm swarm optimization (NMGSO) algorithm (based on the basic glowworm swarm optimization (GSO) algorithm) is proposed for identifying the effective Pareto optimal sensor configurations. The one-dimensional binary coding system is introduced to code the glowworms instead of the real vector coding method. The Hamming distance is employed to describe the divergence of different glowworms. The luciferin level of the glowworm is defined as a function of the rank value (RV) and the crowding distance (CD), which are deduced by non-dominated sorting. In addition, nondirective movement is developed to relocate the glowworms. A numerical simulation of a long-span suspension bridge is performed to demonstrate the effectiveness of the NMGSO algorithm. The results indicate that the NMGSO algorithm is capable of capturing the Pareto optimal sensor configurations with high accuracy and efficiency.

Experimental Study for Establishment of Long-term Monitoring System using Fiber Optical Sensor for Pipeline System for Waste Transportation (광섬유센서를 이용한 쓰레기 이송관로의 장기 계측시스템 구축을 위한 실험적 연구)

  • Kim, Haeng-Bae;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.35-43
    • /
    • 2016
  • Recently, the pipeline system for waste transportation has been increasingly constructed as new solution for the waste collection and disposal system by constantly increasing domestic waste which issued as social problem. The pipeline system is constructed through long distance, so proper long-term monitoring system is necessary which available to detect the damage location for the effective maintenance. In this paper, the experimental study is carried out to evaluate the applicability of optical strain gauge sensor based on FBG for the long-term monitoring system. Three test parameters such as pressure leaking, blockage and deformation are considered as typical damages for real-scale pipeline test specimen. In order to measure flexural and volumetric strain and temperature, three FBG sensors are installed at each monitoring sections. From the test results, this study suggested effective methods of sensor installation and arrangement. Also the sensor spacing for the design of monitoring system using FBG sensor is derived by the correlation of distances from deformation between sensor responses.

Sensor Network Charging Using a Mobile Robot (이동 로봇을 이용한 센서 네트워크의 충전)

  • Kim, Jaehyun;Moon, Chanwoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.747-752
    • /
    • 2020
  • The maintenance of sensor networks, especially sensor networks installed in a wide area for regional monitoring has been an issue for a long time. In this study, a system that supplies energy to the sensor network using a robot is proposed, and the survival conditions of the sensor network are identified using the energy consumption rate of the sensor network, the energy transfer rate, and the moving distance of the robot as variables. Through numerical verification and robot charging simulation, the proposed system survival conditions are shown to be valid, and the feasibility of the maintenance method of the sensor network using the robot is validated through actual charging experiments.

A Study on the Application of Bridge Maintenance System using LoRa LPWAN Wireless Communication (LoRa LPWAN 무선 통신을 활용한 교량 유지관리 시스템 적용성 연구)

  • Park, Jin-o;Park, Sang-Heon;An, Sung-Ju;Park, Won-Joo;Kim, Jong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.138-146
    • /
    • 2019
  • LoRa LPWAN network system uses a license-exempt wireless communication system and implements data measurement through the integrated sensor based on Mems and wireless communication of existing measurement sensors. This system has superior technological / economic superiority using existing network and long distance communication compared to existing wireless measurement system, and secured economical efficiency by minimizing system construction equipment compared to wired measurement system. It is confirmed that the economical efficiency can be reduced by 41% compared to the conventional wired metering system. Since the LoRa LPWAN network system is excellent in terms of maintenance and operation, if installed in many bridges in Korea in the future, it will be developed as an excellent system in the maintenance of bridges. Etc.), and plant field (fire safety, etc.).