• Title/Summary/Keyword: Long-Span Floor System

Search Result 16, Processing Time 0.026 seconds

A simplified method for determining the acceleration amplitudes of long-span floor system under walking/running loads

  • Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.377-387
    • /
    • 2020
  • Modern long-span floor system typically possesses low damping and low natural frequency, presenting a potential vibration sensitivity problem induced by human activities. Field test and numerical analysis methods are available to study this kind of problems, but would be inconvenient for design engineers. This paper proposes a simplified method to determine the acceleration amplitudes of long-span floor system subjected to walking or running load, which can be carried out manually. To theoretically analyze the acceleration response, the floor system is simplified as an anisotropic rectangular plate and the mode decomposition method is used. To facilitate the calculation of acceleration amplitude aP, a coefficient αwmn or αRmn is introduced, with the former depending on the geometry and support condition of floor system and the latter on the contact duration tR and natural frequency. The proposed simplified method is easy for practical use and gives safe structural designs.

An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2011
  • To obtain a lower story height with a long span and better fire resistance, a new composite floor system using GFRP (glass-fiber-reinforced plastics) was proposed. This floor system consists of asymmetric steel with a web opening, a hollow core ball, concrete, and GFRP. To evaluate the flexural performance of the new composite floor system, an experiment was conducted. The test parameters were the presence of GFRP, the void ratio in relation to the hollow core balls, and the web opening. The test results showed that the resistance and stiffness of the specimen with GFRP were 10% higher than those of the reference specimen, and that fully composite action was accomplished up to the yielding point. After the attainment of the yield strength, the ductility of the specimen was reduced due to the stress concentration around the web openings. The slip between the concrete and steel beam, however, was small. Thus, in the design of the proposed new floor systems, it is desirable that the calculated resistance be reduced by 15%, for safety.

Application of Equivalent Walking Loads for Vibration Analysis of Building Floor Subjected to Footstep Loadings (보행하중을 받는 건축물 바닥판의 진동해석을 위한 등가 보행하중의 적용)

  • 김기철;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.35-45
    • /
    • 2001
  • Recently, the floor systems those require large open space may have low inherent damping due to the decline of the use of curtain walls. Furthermore, the use of the high strength materials has resulted in more flexible and longer spanning in floor systems. The long span structures such as shopping malls, offices and large assembly rooms may lead to significant dynamic response due to human activities. Excessive vibrations make the occupants uncomfortable and deteriorate the serviceability of buildings. It is now proved that footfall loading is the major source of floor vibrations. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict measured walking loads and periodic function at a node. But this method could not account for the moving effect of walking. In this study, natural frequency and damping ratio of example structure are evaluated by heel drop tests. And the application of equivalent walking loads is used for on efficient vibration analysis of the plate structures subjected to walking loads.

  • PDF

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Performance Evaluation of Floor Vibration of Biaxial Hollow Slab Subjected to Walking Load (보행하중에 대한 2방향 중공슬래브의 진동성능 평가)

  • Kim, Min-Gyun;Park, Hyun-Jae;Lee, Dong-Guen;Hwang, Hyun-Sik;Kim, Hyun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.11-21
    • /
    • 2009
  • Considering that the weight of a biaxial hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a biaxial hollow slab is not significantly lower than that of a general solid slab, there has been a growing need for biaxial hollow slab systems, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a biaxial hollow slab system are quite different from the conventional floor systems. Therefore, in this study, the floor vibration of a biaxial hollow slab system subjected to walking load is investigated in comparison with a conventional floor slab system. For the efficiency of time history analysis, an equivalent plate slab model that can precisely represent the dynamic behavior of a biaxial hollow slab system is used. From the analytical results, it was determined that vibration of a biaxial hollow slab system subjected to walking load is evaluated as "office-level vibration," according to the classifications of the architectural institute of Japan and ANSI.

A comparative study on different walking load models

  • Wang, Jinping;Chen, Jun
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.847-856
    • /
    • 2017
  • Excessive vibrations can occur in long-span structures such as floors or footbridges due to occupant?s daily activity like walking and cause a so-called vibration serviceability issue. Since 1970s, researchers have proposed many human walking load models, and some of them have even been adopted by major design guidelines. Despite their wide applications in structural vibration serviceability problems, differences between these models in predicting structural responses are not clear. This paper collects 19 popular walking load models and compares their effects on structure?s responses when subjected to the human walking loads. Model parameters are first compared among all these models including orders of components, dynamic load factors, phase angles and function forms. The responses of a single-degree-of-freedom system with various natural frequencies to the 19 load models are then calculated and compared in terms of peak values and root mean square values. Case studies on simulated structures and an existing long-span floor are further presented. Comparisons between predicted responses, guideline requirements and field measurements are conducted. All the results demonstrate that the differences among all the models are significant, indicating that in a practical design, choosing a proper walking load model is crucial for the structure?s vibration serviceability assessment.

A Study on the Dynamic Analysis of One-way Hollow Slab Using Equivalent Plate Element (등가플레이트 요소를 이용한 일방향 중공슬래브의 동적해석에 관한 연구)

  • Kang, Joo-Won;Lim, Jun-Ho;Chae, Seoung-Hun;Kim, Gee-Cheol;Seok, Keun-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.447-454
    • /
    • 2012
  • Considering that the weight of a hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a hollow slab is not significantly lower than that of a general slab, there has been a growing need for hollow slab system, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a hollow slab system are quite different from the conventional floor system. It is required to investigate the safety and the serviceability of hollow slab. Therefore, there exists a necessity for accurate vibration analysis. Hollow slab should be modeled by refined mesh for accurate vibration analysis. For the efficiency of the Eigenvalue Analysis, an equivalent plate slab model when can relatively precisely represent the dynamic behavior of a one-way hollow slab system is used. In conclusion, equivalent plate models relatively precisely presented the dynamic characteristics of one-way hollows.

The Dynamic Characteristics and Serviceability of Long Span Multi-purpose Hall (장스팬 다목적 홀의 동적특성과 사용성)

  • Lee, Sung-Min;Choi, Chui-Kyung;An, Young-Ki;Lee, Soo-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.105-113
    • /
    • 2003
  • Because structural systems are becoming lighter and more flexible and have lower natural frequencies and dampings than before, coordinated rhythmic activities such as dancing, audience participation in arenas or concert halls, and aerobics result in undesirable levels of vibration. For rhythmic activities, it is resonant or near resonant behavior that result in significant dynamic amplification and hence human discomfort. The most rational design strategy is to provide enough of a gap between the natural frequency of a floor system and the dominant frequencies excited by planned human activities to assure reasonably that resonance will not occur. For the case study the vibration measurements were performed at the floor of a long-span multi-purpose hall during the rock concert of popular singer.

Improvement of Flexural Performance for Deep-Deck Plate using Cap Plate (캡플레이트를 이용한 장스팬용 춤이 깊은 데크의 휨성능 개선)

  • Park, K.Y.;Nam, Y.S.;Choi, Y.H.;Kim, Y.H.;Choi, S.M.
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.555-567
    • /
    • 2013
  • Slim floor system using deep decks has been developed and employed in Europe to reduce the floor height of steel structures. Although long span buildings involving the issue of reducing floor height are being increasingly built in Korea, employing deep decks in more than 7m long span structures is likely to cause problems associated with excessive deflection. This study is applied to the long-span concrete casting of the deep deck plate usability of deflection due to bending and torsional instability of open cross-section, as a way to improve the problem of cap plates are suggested, and the optimum length of reinforcement and location are derived from theoretic estimation. The cap plates are placed on the deep decks with regular intervals to overcome the instability of open sections, improve the stiffness of the sections and control the deflection at the centers. The improvement in flexural capacity associated with the location of the cap plates and the length of reinforcement are verified through analysis and test.

Application of Post-Tension Technology on Tall Buildings

  • Chung, Kwangryang;Park, Jungwoo;Kim, Younghye;Kim, Dohun
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.285-296
    • /
    • 2017
  • It's been a decade since post-tension system began to be applied in earnest to buildings in Korea. In the meantime, post-tension system has been used in various buildings as main structural system including tall buildings. And post-tension system plays a role to overcome architectural limit of regular RC tall buildings particularly in the realization of long span with shallower depth than other structural system. The post-tensioned building market of Korea has been steadily grown in recent years with such advantage. Recently, post-tension technology is adapted for special structural members like belt walls. In this paper, the authors would like to explain design and construction of tall buildings in Korea using post-tension technology.